The EDFA’s software is fully automatic and constantly monitors key parameters. These
parameters are stored in the unit’s EEPROM and/or microcontroller. Some may be changed
via external communications.
The unit is designed for local and remote monitoring and control.
Factory Defaults / EEPROM Settings
The software uses EEPROM for memory back up of the lower and upper alarm limits for
analogue parameters and for control variables as set by the user.
These settings will be saved into EEPROM so that the user will not need to reset these in case
of a power failure.
The factory default setting of the unit is to have an IP address of
192.168.1.50
.
The factory default setting is to have the laser switched
off
for all models.
LCD menu Sequence
Press
\
button, the following menu will be displayed in sequence.
A.
Model
Read-only menu, tells the type of this equipment
B.
S/N
Read-only menu, tells the
serial number of this equipment
C.
InputA
Read-only menu, tells the input optical power A of optical switch
D.
InputB
Read-only menu, tells the input optical power B of optical switch
E.
Input
Read-only menu, tells the input optical power of EDFA
F.
OP Route Select
Adjustable list, display the optical route selecting
G.
Op Switch Point
Adjustable list, display the optical switch point setting
H.
Total Output
Read-only menu, tells the output optical power of EDFA in dBm.