ASAHI ASV-320D User Manual Download Page 4

7

6

Check that the canister or tube is not leaking air.

Make sure to close the lid of the liquid catch canister and connect the tube.

Set the sealing time.

Set the seal timer taking bag thickness and

material into account.

(Seal timer number:1=1sec、2=2sec ...)

Checking the seal condition, set the appropriate

seal time as follows. 

Place item(s) in the bag.

Before Placing Items in Bags・・・

-

-

-

-

※ In automatic vacuum mode or manual vacuum mode, make sure the nozzle is out.

Thickness(μm)

60μ 70μ 80μ 90μ 120μ

Sealing time(sec.)

Sealing time (sec.)

+Button

−Button

Select/Pause Button

Operating Instructions

※If the nozzle vacuums the bag or its contents, vacuum mode may automatically switch

    to seal mode even if the bag contains air.  ( See “Operating Instructions”, page 8. )

Green light

Red light

Automatic

Vacuum Mode

Seal Mode

Manual

Vacuum Mode

※In the automatic vacuum mode in embossed bag mode, switching to the seal mode is possible

    by pressing the start button.

Timer button

Power switch

2

1

Check the operation mode.

3

When item volumes are small for the bag size or bags are remarkably thin, it may

make the vacuuming process difficult. If the item voluume is small, prepare a bag

of appropriate size or use an embossed bag.

Please use an embossed bag for powders or highly viscous items such as curry, 

sauce, etc.

When you place item(s) in the bag, prevent water contact with the seal area of

the bag.

Some vegetables emit gases during storage. The bag may inflate after vacuum sealing.

Use bags with high pinhole resistance when packing items with protrusion.

5

4

6

Begin vacuuming after 

placing the bag in position. 

After vacuuming process, 

seal mode will turn on 

automatically.

Checking the degree of 

vacuum, this mode can 

switch to the userʼs selected 

seal mode. After the bag is 

inserted, vacuum mode 

continues. Press the start 

button again and turn on 

seal mode.

This mode seals the bag 

only. Use this mode when 

items do not need vacuum 

or you want to perform the 

sealing process manually.

The light on the cover top indicates operating mode and progress.

Manual

Vacuum Mode

Seal

Mode

Automatic

Vacuum Mode

Manual

Vacuum Mode

Seal

Mode

Automatic

Vacuum Mode

- Standard vacuum bags mode -

- Standard vacuum bag mode -

- Embossed vacuum bags mode -

- Embossed vacuum bag mode -

Plug the power cord into the receptacle outlet.

Set the bag type as required when turning on the switch.

Turn on the power switch

while pressing down the

mainus(−) button.

The light turns on.

Turn on the power switch

while pressing down the

plus(+) button.

The light blinks slowly.

To select the bag mode, turn

on the power switch while

pressing down the + (plus)

button or-(minus) button of

the timer.

If turning on the power

without pressing the timer

button, the previously used

mode will be continued.

Set the operation mode.

There are three operation modes for

the standard vacuum bag mode and

embossed bag mode respectively. 

Each time the select button is pressed,

the light indicator changes on the cover, 

and the mode will change as follows.

The red light

turns on

The red light

blinks slowly

The green light

turns on

The green light

blinks slowly

The Both lights

turn on

The both lights

blink slowly

ex. Standard nylon-poly vacuum bag

Summary of Contents for ASV-320D

Page 1: ...1 If no warranty is shown 2 If the required information is not lled in or is rewritten 3 If the malfunction was caused by misuse 4 If the malfunction was caused by impact during shipment or movement...

Page 2: ...not hold near ame or use in an unstable location This may result in re injury or deformation When vacuum packing do not vacuum liquid without attaching the liquid catch canister Do not put ngers on th...

Page 3: ...of the bag in seal mode and perform vacuum packing There are bags of various sizes thicknesses and speci cations with a smooth surface When storing food choose the usage purpose of the unit in conside...

Page 4: ...n packing items with protrusion 5 4 6 Begin vacuuming after placing the bag in position After vacuuming process seal mode will turn on automatically Checking the degree of vacuum this mode can switch...

Page 5: ...um nozzle Be sure to insert the bag as far as possible Press the start button Make sure the sealing process is complete and remove the bag The seal bar moves down and holds the bag When the sealing pr...

Page 6: ...ing contents close to the nozzle in standard vacuum bag mode Cleaning Clean the nozzle after use to prevent clogging Cleaning with lukewarm water Vacuuming lukewarm water cleans the inside of the nozz...

Page 7: ...zle from the unit Make sure to turn the unit o before cleaning Make sure to turn the unit o before cleaning 1 2 Open the cover of the liquid catch canister to remove it and its lid and remove its prot...

Page 8: ...Cut or change the bag to the appropriate size Place the bag properly Replace the PTFT strip Please contact the store where you made the purchase Check the PTFT strip for wrinkles or cracks Make sure...

Reviews: