Command Line Interface
Special Commands
SAVE
30
www.arwestcom.com
3.4.4. SAVE
The SAVE command is intended to store the unit’s currently used configuration into the User
Configuration file. The configuration stored in the User Configuration file is activated by
automatically after unit’s reboot.
3.4.5. SLEEP
The SLEEP command determines the sleep mode parameters. The sleeping AW400Tx can be
activated by real-time CLK, DTR/RTS lines, and command received through TTL inputs. The
user can select one, two, or all three conditions.
SLEEP [Parameter Name] [Parameters List] [/?]
Parameter Name
Parameter List
CLK
0 – Do not activate by internal real-time clock
(1 – 255) – Activate by internal real-time clock after 100 to 25500 msec of sleeping
HW
0 – Do not activate through DTR/RTS lines
1 – Activate through DTR/RTS lines
TTL
0 – Do not activate by external sense lines
1 – Activate by external sense lines
GTS
0 – Disable Sleep mode (default)
(1 – 255) – Go to sleep mode if there is no activity in 10 to 2550 msec