Specifications

|

65

UL60950-1, CSA 22.2 No 60950-1

UL/CL 62368-1:2nd Edition

CSA C22.2 NO. 62368-1-14, 2nd Edition

EMC

EN 55024:2010+A2016/CISPR24:2015

EN 55032:2015/CISPR32 Class A

EN55035:2017/CISPR35

EN 61000-3-2:2014, Class A

EN 61000-3-3:2013

FCC CFR 47 Part 15:2010 Class A

ICES-003 Class A

VCCI Class A

CNS 13438 Class A

RoHS

EN 50581:2012

n

When selecting a fiber SFP or QSFP device, make sure the device has the same (or better) operating
temperature range as the switch.

n

Use only an approved Laser Class 1 SFP transceiver.

n

The maximum number of DAC cables supported in JL700C, JL701C, and JL717C ports 1-4 is two.

Japan Power Cord
Warning

Connectivity Standards

These connectivity standards are general and may not apply to your 8360 series switch.

Technology

Compatible with these
IEEE standards

EN/IEC standard com-
pliance

Lasers

100-TX1000-T10GBASE-T

IEEE 802.3u 100BASE-TX

IEEE 802.3ab 1000BASE-T

IEEE 802.3an 10GBASE-T

1000-SX

IEEE 802.3z 1000BASE-SX

EN/IEC 60825

Class 1 Laser
Product

Laser Klasse 1

1000-LX

IEEE 802.3z 1000BASE-LX

EN/IEC 60825

Class 1 Laser
Product

Summary of Contents for 8360 Series

Page 1: ...Aruba 8360 Switch Series Installation and Getting Started Guide Published May 2022 Edition 2...

Page 2: ...rth in the express warranty statements accompanying such products and services Nothing herein should be construed as constituting an additional warranty Hewlett Packard Enterprise shall not be liable...

Page 3: ...Power Supply Instructions 27 Power Supply Status LED 28 Load Sharing 28 Redundancy 28 Hot Swapping 28 Fan Trays 29 Fan Tray Status LED 30 Switch Features 31 Installing the switch 32 Included Parts 32...

Page 4: ...ic Tests 56 Testing the switch by resetting it 56 Checking the Switch LEDs 56 Checking Console Messages 56 Testing Switch to Device Network Communications 56 Testing End to End Networking Communicatio...

Page 5: ...702A Aruba 8360 32Y4C v2 FB 3F 2AC Bdl JL700C Aruba 8360 16Y2C Pwr2Prt3F2PS Bdl JL703A Aruba 8360 32Y4C v2 BF 3F 2AC Bdl JL701C Aruba 8360 48Y6C v2 FB 5F 2AC Bdl JL704C Aruba 8360 16Y2C v2 FB 3F 2AC B...

Page 6: ...low Terminology Revs A Airflow Terminology Equivalent Rev C Port to Power Prt2Pwr Front to Back FB Power to Port Pwr2Prt Back to Front BF Related Publications n Start Here Installation Safety and Regu...

Page 7: ...anagement ports o Power supplies o Fan trays n Switch features Overview The Aruba 8360 Switch Series is a family of premium networking switches ideal for enterprise data centers network aggregation an...

Page 8: ...on 1 JL700A JL701A Aruba 8360 32Y4C 2 JL702A JL703A Aruba 8360 16Y2C 3 JL706A JL707A Aruba 8360 48XT4C 4 JL708A JL709A Aruba 8360 12C 5 JL710A JL711A Aruba 8360 24XF2C 6 JL704C JL705C Aruba 8360 48Y6C...

Page 9: ...Aruba 8360 Switch Series Installation and Getting Started Guide 9 Figure 2 Front of all 8360 rev C switches...

Page 10: ...rts For SFP28 QSFP QSFP28 operation only Aruba supported Transceivers AOCs or DACs are allowed For SFP SFP operation there is an Unsupported Transceiver mode available however no warranty or support a...

Page 11: ...able 1 Network Port descriptions for Aruba v2 C model switches Switch Model name SFP28 ports QSFP28 ports 10G Base t ports MACsec ports JL700C JL701C v2 JL717C v2 Aruba 8360 32Y4C Aruba 8360 32Y4C v2...

Page 12: ...link in unison for Link Activity or Mode behavior see LED Behavior on page 21 When in split mode each of the 4 LEDs corresponds to one of the split ports 1 4 left to right respectively QSFP28 ports on...

Page 13: ...de for your switch and software release Out of band Management OOBM Port This front panel RJ 45 port is used to connect a dedicated management network to the switch To use it connect an RJ 45 network...

Page 14: ...r and Global Status 4 Reserved for future use 5 Out Of Band Management Link Activity LED 6 Out Of Band Management Port 1000 100 10 Mbps 7 USB2 0 Type A port Aux 8 Luggage Tab Contains Product and Unit...

Page 15: ...L707A JL720A Label Description 1 Top left and Bottom right RJ 45 port indicator LEDs 2 QSFP port indicator LEDs 3 System LEDs Back Status Unit Identification Locator and Global Status 4 Reserved for f...

Page 16: ...4 Reserved for future use 5 Out of Band Management Link Activity LED 6 1000 100 10 Mbps Out Of Band Management Port 7 USB2 0 Type A Port Labeled Aux 8 Luggage Tab Contains Product and Unit Identificat...

Page 17: ...ceivers AOCs or DACs are allowed For SFP SFP operation there is an Unsupported Transceiver mode available however no warranty or support are provided for the transceiver cable when used 50G support av...

Page 18: ...EDs for the Aruba 8360 16Y2C JL702C JL703C JL718C Label Description 1 16 SFP28 Ports 2 Port mode LEDs 3 System LEDs 4 1000 100 10 Mbps Out Of Band Management Port 5 USB2 0 Type A Port Labeled Aux 6 Lu...

Page 19: ...ssis and Port LEDs for the Aruba 8360 48XT4C JL706C JL707C JL720C Label Description 1 48 10GBase T ports 2 Port mode LEDs 3 System LEDs Back Status Unit Identification Locator and Global Status 4 1000...

Page 20: ...Status 4 Reserved for future use 5 Out of Band Management Link Activity LED 6 1000 100 10 Mbps Out Of Band Management Port 7 USB2 0 Type A Port Labeled Aux 8 Luggage Tab Contains Product and Unit Iden...

Page 21: ...next to the button To step from one view mode to the next press the button to cycle through the different modes n Usr2 LED is reserved for future use and cannot be selected with the LED mode button L...

Page 22: ...th Global Status LED Fault Out Of Band Management Link Activity Displays Link and Activity information for the OOBM port Startup OFF No valid link OS CX and SVOS Normal OFF No valid link Half Bright G...

Page 23: ...tes status of modular assemblies on the back of the switch Power supplies and Fan trays Startup OFF Normal ON Green Fault FLASH Amber Blinks synchronously with Global Status LED PSU or Fan fault Switc...

Page 24: ...itches include two power supply units and three fan trays All 8360 SKUs have three fan trays with the exception of 8360 48Y6C Refer to Figure 2 in this section for more information on the rear of 8360...

Page 25: ...tch The back of 8360 48Y6C switches include five fan modules Label Description 1 2 Health and UID LEDs 3 RJ 45 Serial Console Port 4 AC Inlet C14 socket 5 Power Supply Status LED 6 Fan Trays 1 5 7 Opt...

Page 26: ...Verify that cord has been disconnected from the power supply before installation or removal The Aruba 8360 switch power supplies adapt electrical power for use with the switch The chassis has two slo...

Page 27: ...ppable field replaceable AC power supplies Each power supply has a country specific power cord for connection to an AC power outlet The switch can operate with one active power supply Power Supply Ins...

Page 28: ...ng Load sharing occurs when two power supplies are installed in the switch and powered on Load sharing divides the total power load of the switch among both power supplies Redundancy With power redund...

Page 29: ...trays is required for operation If fewer than three working fan trays are detected the Global status Rear status and corresponding Fan Tray LEDs will FLASH amber For the 8360 48Y6C a minimum of four...

Page 30: ...perate with one failed fan tray If the switch reaches an overtemp condition the switch will shut down For best operation the failed fan tray should be replaced as soon as possible If one fan tray has...

Page 31: ...wer supply continues to provide the power necessary to keep the switch running n Easy management of the switch through several available interfaces o Command line interface A full featured easy to use...

Page 32: ...Two power cords required per switch Argentina 8121 0729 J9891A Israel 8121 1004 J9899A Australia New Zealand 8121 0837 J9883A Japan 8121 1143 J9893A Brazil 8121 1071 J9894A Switzerland 8121 0738 J989...

Page 33: ...uded If you have not already done so order an Aruba rack mount kit for use with your 8360 switch Rack mounting your Aruba 8360 switch is supported using these rack mount kits n JL9583B Aruba X414 1U U...

Page 34: ...etermine the possibility of overloading the supply circuits add the ampere ratings of all devices installed on the same circuit as the switch Then compare the total with the rating limit for the circu...

Page 35: ...elines on page 33 before starting installation Install Power Supplies Prerequisites Skip this step if two power supplies are already installed in the switch If two power supplies are not already insta...

Page 36: ...If fewer than three working fan trays are detected the Global status Rear status and corresponding Fan Tray LEDs will FLASH amber For the 8360 48Y6C a minimum of four working fan trays is required fo...

Page 37: ...etail see Checking the Switch LEDs on page 56 Power off the switch Prerequisites Remove the power cord from the switch and from the power source Mount the Switch The supported mounting options for the...

Page 38: ...racks If installing the switch in an equipment cabinet such as a server cabinet use the clips and screws that came with the cabinet in place of the 12 24 screws that are supplied with the two post ra...

Page 39: ...rackets to the switch The mounting brackets have multiple mounting holes and can be rotated allowing for a wide variety of mounting options 2 Hold the switch with attached brackets up to the rack and...

Page 40: ...our post rack mount kit J9583B Complete step 1 and plan which holes you will be using in the cabinet and install all four clips Then proceed to step 2 1 Use a T20 drive screwdriver and attach the fron...

Page 41: ...uine Aruba transceivers is always recommended Non Aruba SFP28 QSFP QSFP28 transceivers are not supported Non Aruba SFP SFP transceivers can be used in unsupported transceiver mode but no support or wa...

Page 42: ...witches and switch ports that support EMI plugs see Table 2 Figure 1 Installing EMI plug into a JL719C JL704C JL705C Aruba 8360 48Y6C v2 Switch Warning in order to comply with Radiatede Emission Class...

Page 43: ...ven port fr 6 to 32 JL701C Aruba 8360 32Y4C v2 BF 3F 2AC Bdl 14 EMI plug All odd port fr 5 to 31 50G Transceiver All even port fr 6 to 32 JL717C Aruba 8360 32Y4C v2 Switch 14 EMI plug All odd port fr...

Page 44: ...Switches Label Description 1 JL717C JL700C JL701C Aruba 8360 32Y4C v2 2 JL718C JL702C JL703C Aruba 8360 16Y2C v2 3 JL719C JL704C JL705C Aruba 8360 48Y6C v2 Connect the Switch to a Power Source 1 If t...

Page 45: ...A DB9 to RJ 45 console cable can be ordered from HPE JL448A Aruba X2C2 RJ45 to DB9 Console Cable For more information about this method see Initial Configuration with an Out of Band Serial Connection...

Page 46: ...ansceivers installed See Cabling and Technology Information For transceiver ports and in general for all the switch ports a network cable from an active network device is connected to the port If the...

Page 47: ...change the terminal settings then reboot the switch and reestablish the console session Connect to Console Port To connect a console to the switch follow these steps 1 Connect the PC or terminal to t...

Page 48: ...and Serial Connection 48 RJ 45 to DB 9 pinouts RJ 45 Signal reference from chassis DB 9 Signal reference from PC Reserved 1 8 CTS Reserved 2 6 DSR TXD 3 2 RXD Reserved 4 1 DCD GND 5 5 GND RXD 6 3 TXD...

Page 49: ...while the power cord is connected Verify that cord has been disconnected from the power supply before installation or removal If the Aruba 8360 switch is configured with a redundant power supply the...

Page 50: ...Slide it all the way in until the locking mechanism clicks into place 4 Connect the AC power cable to the new power supply s connector Replacing a Fan Tray The Aruba 8360 switch is equipped with three...

Page 51: ...ntil you have the replacement fan tray prepared Ensure that a replacement fan tray has the same airflow as other fan trays installed in the switch Port to Power or Power to Port To replace a fan tray...

Page 52: ...ng and technology information for pinouts and correct cable wiring n Improper network topologies It is important to make sure you have a valid network topology Common topology faults include excessive...

Page 53: ...shing amber Flashing amber 6 On green On green Off with cable connected 7 On green On green On but the port is not communicating 8 Diagnostic Tips Tip Problem Solution 1 Both switch power supplies are...

Page 54: ...ED is flashing has experienced a self test initialization failure or group speed mismatch Check the switch Event Log and show interface command output for indication of the fault condition If a port f...

Page 55: ...t all Run an internal selftest on the port For example to run a selftest on port 1 1 12 diagnostics diagnostics loopback 1 1 12 If the command reports fail contact Support There may be a hardware faul...

Page 56: ...om the console using the show events command Testing Switch to Device Network Communications You can perform the following communication tests to verify the network is operating correctly between the...

Page 57: ...may contain perchlorate material Special handling may apply in California and certain other states See http www dtsc ca gov hazardouswaste perchlorate website for more information The only indicator...

Page 58: ...in 406 4 cm 16 0 in 4 4 cm 1 73 in 8 19 kg 18 05 lb Aruba 8360 16Y2C JL718A Aruba 8360 16Y2C PrtToPwr Configuration JL702A Aruba 8360 16Y2C PwrToPrt Configuration JL703A Aruba 8360 16Y2C v2 FB 3F 2AC...

Page 59: ...44 25 cm 17 4 406 4 cm 16 0 in 4 4 cm 1 73 in 8 07 kg 17 08 lb Aruba 8360 48XT4C JL720A Aruba 8360 48XT4C PrtToPwr JL706A Aruba 8360 48XT4C PwrToPrt JL707A 44 25 cm 17 4 406 4 cm 16 0 in 4 4 cm 1 73...

Page 60: ...127VAC 3 4A for 200 240VAC 100 127 200 240 47 63 Hz Aruba 8360 16Y2C Prt2Pwr3F2PS Bdl JL702A Aruba 8360 32Y4C v2 FB 3F 2AC Bdl JL700C Aruba 8360 16Y2C v2 FB 3F 2AC Bdl JL702C Aruba 8360 48XT4C Prt2Pw...

Page 61: ...240 volts Power Cords Aruba includes the power cord intended for use with your Aruba switch and power supply Different countries regions may require different power cords For a list of the power cords...

Page 62: ...2AC Bdl JL701C Max 425 W Idle 120 W Aruba 8360 16Y2C PrtToPwr JL702A Aruba 8360 16Y2C PwrToPrt JL703A Aruba 8360 16Y2C v2 FB 3F 2AC Bdl JL702C Aruba 8360 16Y2C v2 BF 3F 2AC Bdl JL703C Max 325 W Idle...

Page 63: ...to 10000 ft 2 Up to 5000 ft derate 1 C for every 1000 ft from 5000 ft to 10000 ft 3 At 113 F 45 C non condensing 4 At 104 F 40 C non condensing 5 At 149 F 65 C non condensing 6 At 149 F 65 C non cond...

Page 64: ...re LpAm Bystander 45 4 dB Sound Power LWAd 6 3 Bel Aruba 8360 48Y6C v2 BF 5F 2PS Configuration JL705C Sound Pressure LpAm Bystander 45 8 dB Sound Power LWAd 6 4 Bel Acoustics measured in 23 2 C hemi a...

Page 65: ...ng temperature range as the switch n Use only an approved Laser Class 1 SFP transceiver n The maximum number of DAC cables supported in JL700C JL701C and JL717C ports 1 4 is two Japan Power Cord Warni...

Page 66: ...er Klasse 1 40G ER4 IEEE 802 3bm 2015 40GBASE ER4 EN IEC 60825 Class 1 Laser Product Laser Klasse 1 40Gig Bidi not an IEEE standard EN IEC 60825 Class 1 Laser Product Laser Klasse 1 40 Gig SR4 IEEE 80...

Page 67: ...EC 60825 Class 1 Laser Product Laser Klasse 1 25 Gig eSR not an IEEE standard EN IEC 60825 Class 1 Laser Product Laser Klasse 1 25 Gig LR IEEE 802 3cc 25GBASE LR EN IEC 60825 Class 1 Laser Product Las...

Page 68: ...ir UTP or STP cable complying with IEEE 802 3ab 1000BASE T specifications Category 5e or better is recommended 10 Gbps Operation Category 6 or 6A 100 ohm 4 pair UTP cable or Category 6A or 7 100 ohm 4...

Page 69: ...cations as described in the TIA 568 C ANSI TIA 568 C 2 and ISO IEC 11801 standards 10GBASE T is a sophisticated technology that relies upon high quality cable installations It is sensitive to Alien Ne...

Page 70: ...00 MHz km 2000 MHz km 2 26 meters 2 33 meters 2 66 meters 2 82 meters 2 300 meters 10GBASE LR single mode fiber N A 2 10 000 meters 10GBASE ER single mode fiber N A 2 40 000 meters 25GBASE CR twinaxia...

Page 71: ...fiber N A 2 10 000 meters 40GBASE ER4 single mode fiber N A 2 40 000 meters 40GBASE BiDi multimode fiber 1500 MHz km 3500 MHz km 2 100 meters 2 150 meters 100GBASE CR4 twinaxial copper N A various le...

Page 72: ...ting Support n Technical support registration number if applicable n Product name model or version and serial number n Operating system name and version n Firmware version n Error messages n Product s...

Page 73: ...ces are viewable without an ASP account Warranty Information To view warranty information for your product go to https www arubanetworks com support services product warranties Regulatory Information...

Reviews: