Valve body 

#2 compression fitting 

# 1 male stub 

                                                              INSTALLATION STEPS  

Valve Diagram 

 
NOTE:  this diagram shows a PX40 angled valve.  PX41 straight valves are also 
available.  The same installation steps can be followed, but supply pipes must 
enter through the floor rather than through the wall. 

Summary of Contents for MR12045H

Page 1: ...www artos westover com Installation Guide Ryton Towel Warmer MR12045H hydronic version ...

Page 2: ...d understood the following instructions Electrical and plumbing connections must be carried out by qualified personnel and the unit should be securely mounted to the wall in a vertical position The following pages are to assist in installation In case of damages or failures of the rail connection the towel rail should be returned to the manufacturer or their distributor The warranty from the manuf...

Page 3: ...ing warm water and a soft cloth will retain the high quality finish of your towel warmer for many years to come ON NO ACCOUNT should any household bleaches detergents abrasive polish steel wool or similar cleaning agents be used on this product WALL FIXING Towel warmer brackets must be securely fastened to either masonry wall studs or plywood board in accordance with the fitting instructions PACKA...

Page 4: ...ircuit for the towel warmer Refer to page 3 for piping locations The valve shown above is an angled valve which requires piping through the wall Straight valves are also available for piping com ing through the floor Piping to towel warmer valves should be 1 2 copper Note Posi tion towel warmer so that at least two of the brackets are attached to a firm wall stud Brackets Valve X 2 Hot water to ot...

Page 5: ... on the top brackets 3 Insert the smaller tubes now attached to towel warmer into the larger tubes and fas ten with the locking screw Valve Installation use Diagram on page 6 as a guide 1 Thread 1 male stub into female inlets on bottom of towel warmer using a threadlocking substance 2 Push 2 compression fitting onto supply pipe and tighten onto valve body 3 Tighten 1 male stub now attached to towe...

Page 6: ... stub INSTALLATION STEPS Valve Diagram NOTE this diagram shows a PX40 angled valve PX41 straight valves are also available The same installation steps can be followed but supply pipes must enter through the floor rather than through the wall ...

Page 7: ...dry cloth WARRANTY This warranty covers against defective products for a period of five years Under the warranty we will provide replacement components or products at our discretion Damage caused by accident misuse abuse improper installation improper cleaning or alteration will void the warranty Westover Inc is not responsible for labor charges installation or other incidental or consequential co...

Reviews: