background image

 

Page 5 

DMX-Buffer, DMX-Clarify & DMX-Protect User Guide

Overview

DMX-Buffer & DMX-Clarify

DMX-Protect

 

y

Each product provides an extra 300m of 

cable run

 

y

Protected (non-isolated) input

 

y

Single buffered output 

 

y

DMX-Buffer  supports  RDM,  allowing 

remote configuration of the fixtures

 

y

DMX-Clarify filters out RDM (see detailed  

operation below)

 

y

Powered from a standard 9V PSU with DC 

jack connector; protective metal case

 

y

Data  input:  standard  5-pin  male  XLR 

connector with internal termination

 

y

Data output: standard 5-pin female XLR 

connector

 

y

DMX-Buffer  is  also  available  with  RJ45 

Ethercon input/output connectors

 

y

Passive in-line protector

 

y

Bidirectional protection - both I/P & O/P 

are protected from fault on other side

 

y

Protects against accidental connection to 

mains (recoverable fault)

 

y

Sacrificial  protection  against  lightning 

strikes (non-recoverable fault)

 

y

Supports RDM

 

y

Protective metal case 

 

y

Data  input:  standard  5-pin  male  XLR 

connector with internal termination

 

y

Data output: standard 5-pin female XLR

DMX-Buffer  and  DMX-Clarify  are  designed 

to allow a DMX line to run further than  the 

standard limit of 300m, without the need for 

expensive DMX splitters. They achieve this by 

internally re-buffering the DMX signal. 
The difference between the products lies in 

the way they handle RDM data.

DMX-Protect is a passive in-line protector 

designed to protect a DMX line from damage 

due  to  electrocution.  It  has  two  levels  of 

protection. 

The first is a self-healing circuit that protects 

against accidental connection to mains and 

will recover when the fault is removed. 

The second is a ‘protection of last resort’ that 

will  sacrifice  the  product  in  order  to  protect 

against high energy faults such as lightning 

strikes.

DMX-Clarify detailed operation

DMX-Clarify is designed to solve product compatibility problems. There are numerous products 

on the market that will not accept the wide range of legal DMX timings and data. DMX-Clarify 

cleans out any unusual or non-standard timing and data before sending to the output. This 

includes stripping out all non-zero start codes (including RDM), forcing a 512-channel footprint 

and calming any timing jitter. 

 

y

Accepts and corrects break in range 56 µs – 1000 µs and outputs 250 µs

 

y

Accepts and corrects MaB in range 5 µs – 1000 µs and outputs 30 µs

 

y

Accepts and corrects MaB in range 0 µs – 1000 µs and outputs 30 µs

 

y

Accepts channel count 1 – 512 and outputs 512

 

y

Accepts refresh period from 23 ms – 1000 ms and outputs 30ms

 

y

Filters out multiple consecutive breaks

 

y

Re-times bytes of 1 stop bit to 2 stop bits

 

y

Filters out all non-zero start code packets

 

y

Re-times digital signal

Summary of Contents for DMX-Buffer

Page 1: ...Artistic Licence DMX Buffer DMX Clarify DMX Protect User Guide DMX Buffer DMX Clarify DMX Protect Version 1 1 User Guide ...

Page 2: ...eable parts inside the outer case of this product Always disconnect from the power supply when not in use Any specific IP rating where appropriate is given in the instructions Unless otherwise stated this product is designed for indoor use only If used outdoors it MUST be installed in an appropriate IP rated cabinet Do not allow this product to be exposed to rain or moisture Do not allow liquid to...

Page 3: ...y DMX Protect User Guide Reference Type Description 1 Connection Data out 2 Connection Data in 3 Connection Power Input 4 LED Power indication 5 LED Data indication 6 Connection GND Connections 6 DMX Buffer DMX Clarify DMX Protect ...

Page 4: ...nd referenced Pin 1 Connected to Internal Logic Ground DMX512 Output Type Ground referenced Pin 1 Connected to Internal Logic Ground Internal Logic Ground Connects to Ground Power Input XLR Pin convention Function Colour RJ45 Pin Cable Colour 1 Ground Black 7 8 White Brown Brown 2 Data Blue 2 Orange 3 Data Red 1 White Or ange 4 Aux Data 6 Green 5 Aux Data 3 White Green ...

Page 5: ...buffering the DMX signal The difference between the products lies in the way they handle RDM data DMX Protect is a passive in line protector designed to protect a DMX line from damage due to electrocution It has two levels of protection The first is a self healing circuit that protects against accidental connection to mains and will recover when the fault is removed The second is a protection of l...

Page 6: ...elow DMX Clarify is used as an in line buffer to provide a filtered DMX signal to a group of fixtures that cannot handle RDM Terminated DMX Controller Fixture 32 Fixture 32 DMX DMX DMX Clarify Devices with DMX compatibility issues Fixture 1 Fixture 1 Fixture 2 Fixture 2 In the diagram below DMX Protect ensures that the DMX controller will not be damaged in the event of accidental mains connection ...

Page 7: ...r only RJ45 Ethercon 1 no Control y y Input Protocols DMX512 DMX512 1990 DMX512 A RDM V1 0 E1 20 2006 ESTA Standard y y Output Protocols Same as input except that DMX Clarify does not output RDM LED Indication y y Power Data Package Contents y y DMX Buffer XLR or RJ45 or DMX Clarify y y User guide Accessories not included y y PSU 9 1 5 DCJ DMX Input y y Input mode Ground referenced y y Input isola...

Page 8: ... All Products manufactured or sold by Artistic Licence Engineering Ltd are fully compliant with the appropriate CE and RoHS regulations Product specific information is available on request Waste Electrical Electronic Equipment WEEE Artistic Licence is a member of a WEEE compliance scheme and will happily recycle any of our products that you at your expense return to us Due to our policy of continu...