EPC-27 Hardware Reference
Page E8
E
E
Error Message
INVALID TARGET SIZE SPECIFIED
Explanation
An illegal character was detected in the file size portion of
the
/F
parameter.
Resolution
Specify the file size using only hex characters.
Error Message
MORE THAN ONE SOURCE PATH WAS SPECIFIED
Explanation
Multiple source paths were detected on the command line.
Resolution
Remove one of the source paths from
XFORMAT
's
invocation line.
Error Message
NO ARGUMENTS SPECIFIED
Explanation
The command line does not specify any operations.
Resolution
Execute
XFORMAT
with
/H
to display flags and options.
Error Message
NO SLOT SELECTED FOR THE EXM-2
Explanation
XFORMAT
requires specification of a slot when
formatting SRAM and EXM flash memory.
Resolution
Rerun
XFORMAT
using the
/P
(osition) flag to indicate
which EXM slot to format.
Error Message
NO SRAM MEMORY IN SPECIFIED SLOT
Explanation
The
/T=S
option was selected, however, no SRAM memory
was detected on the card in the specified slot.
Resolution
Ensure the
/P
(osition) flag is correct or that the
/T
(ype) flag
is specified correctly.
Error Message
SOURCE PATHNAME TOO LONG
Explanation
Insufficient storage for the pathname string.
Resolution
Copy the files to a directory that is closer to the root.
Error Message
SLOT <n> DOES NOT CONTAIN ENABLED
EXM-2
Explanation
The slot number specified in the
SRAMDISK.SYS
configuration line in
CONFIG.SYS
does not contain
enabled flash memory.
Resolution
Enable the flash in the EXM Setup Screen, or verify that
the flash is listed in the correct slot.