6.  Windows Manager Utility                                                                                     

Windows Manager Utility is a software provided by Artila that is used to configure and 

test devices though network. 

 

6.1 Download Windows Manager Utility and Installation 

You may visit Artila website: 

http://www.artila.com/

, then click “Download” 

 

Select “Aport-213” at Download page that shows the product series. 

http://www.artila.com/download/APORT/APORT-213/

 

 

You may also go for product category: “Industrial Communication Gateway” 

At model APORT-213, click 

  to download Artila Manager utility 

 

After downloaded, Execute the file “AXMR2W_RS232-to-WiFi_Toolkit” as an 

administrator for Windows utility installation. 

 

6.2 Connect Aport-213 

After well connected by choosing the WiFi SSID: APORT-213 at WiFi table that       

Aport-213 can be configured easily through remote utility. 

 

Summary of Contents for Aport-213

Page 1: ...Copyright Artila Electronics Co Ltd All Rights Reserved Aport 213 One Port Serial to WiFi Gateway User s Guide Version 1 01 2018 APR ...

Page 2: ...but not limited to its particular purpose Artila reserves the right to make improvements and or changes to this manual or to the products and or the programs described in this manual at any time Information provided in this manual is intended to be accurate and reliable However Artila assumes no responsibility for its use or for any infringements on the rights of third parties that may result from...

Page 3: ...Aport 213 User s Guide ARTILA 3 Document Amendment History Revision Date Remark V 1 0 2017 Oct Initial V 1 01 2018 Apr Figure updated ...

Page 4: ... 13 4 Pin Assignment and Definitions 14 4 1 LED Indicators 14 4 2 Serial Port 15 4 3 Buttons SW1 SW3 16 4 4 Switch SW4 16 4 5 Serial Console 17 4 6 Power Connector 17 4 7 Micro USB Port 16 4 8 PIN Assignment and Definitions J7 J8 17 5 Configure via Web Browser 18 5 1 Connect Aport 213 through browser 18 5 2 Configure Aport 213 19 5 2 1 Basic 19 5 2 2 Advanced 20 5 2 3 Security 21 5 2 4 WiFi 21 5 2...

Page 5: ...the Windows Manager Utility 25 6 4 Device Manager 26 6 5 Virtual Serial Port 27 6 5 1 Operating Functions 27 6 5 2 Creat a Cirtual Serial Port 28 6 5 3 Set a Virtual Serial Port 30 6 6 Virtual Serial Port Operation Example 31 6 7 Device Monitor 33 6 8 COM Port Terminal 34 ...

Page 6: ...teway Supports TCP Server mode and TCP Client mode Secure data access with WEP 64 128 WPA WPA2 Security WEP 64 128 WPA WPA2 Windows application Utility Radio frequency support FCC ETSI worldwide domain Firmware remotely upgradeable 1 2 Specifications General Buzzer Yes LED Indicator Power Status COM Serial Console RF output power 802 11b 16 2dBm 802 11g 14 2dBm 802 11n 13 2dBmH Dimensions W x L x ...

Page 7: ...bps 802 11g 82dBm 6Mbps 81dBm 9Mbps 79dBm 12Mbps 77dBm 18Mbps 74dBm 24Mbps 70dBm 36Mbps 66dBm 48Mbps 65dBm 54Mbps 802 11n 20MHz 82dBm MCS0 79dBm MCS1 77dBm MCS2 74dBm MCS3 70dBm MCS4 66dBm MCS5 65dBm MCS6 64dBm MCS7 802 11n 40MHz 79dBm MCS0 76dBm MCS1 74dBm MCS2 71dBm MCS3 67dBm MCS4 63dBm MCS5 Security WEP 64 128 WPA WPA2 Protocol support TCP UDP ICMP IGMP IPv4 DHCP ARP DNS SMTP SNTP RFC2217 and ...

Page 8: ...ity Web Serial Console Connector DB9 Female Signals TX RX GND Operation System Real Time OS FreeRTOS Management Web server Serial Console Windows Application Utility 1 3 Packing List Aport 213 One Port Serial to WiFi Gateway 1 4 Optional Accessory DK 35A PN 36 DK35A 000 DIN RAIL Mounting Kit PWR 12V 1A PN 31 62100 000 110 240VAC to 12VDC 1A Power Adaptor 1 5 Optional Module SW 200M PN 91 XXXX 000 ...

Page 9: ...Aport 213 User s Guide ARTILA 9 2 Layout 2 1 Outline ...

Page 10: ...Aport 213 User s Guide ARTILA 10 2 2 Dimension Unit mm ...

Page 11: ...antenna Supports Simple Config API for Mobile APP Arm Cortex M3 166MHz 1MB ROM 512KB RAM 2MB SDRAM 4x GPIOs 1x UART Interface 1x I2C interface Supports real time OS Web Serial consoles for device configuration WiFi Gateway AP mode Station mode WiFi WPS WiFi direct Modbus RTU to Modbus TCP Gateway Supports TCP Server mode and TCP Client mode Secure data access with WEP 64 128 WPA WPA2 Security WEP ...

Page 12: ... OFDM 20dBm 802 11n 20dBm Receive Sensitivity 802 11b 80dBm 1Mbps 80dBm 2Mbps 79dBm 5 5Mbps 76dBm 11Mbps 802 11g 82dBm 6Mbps 81dBm 9Mbps 79dBm 12Mbps 77dBm 18Mbps 74dBm 24Mbps 70dBm 36Mbps 66dBm 48Mbps 65dBm 54Mbps 802 11n 20MHz 82dBm MCS0 79dBm MCS1 77dBm MCS2 74dBm MCS3 70dBm MCS4 66dBm MCS5 65dBm MCS6 64dBm MCS7 802 11n 40MHz 79dBm MCS0 76dBm MCS1 74dBm MCS2 71dBm MCS3 67dBm MCS4 63dBm MCS5 Sec...

Page 13: ...A_6 2 UART Log in GPIOB_1 2 UART0_OUT GPIOA_7 3 I2C SCL GPIOB_2 3 UART0_RTS GPIOA_3 4 I2C SDA GPIOB_3 4 UART0_CTS GPIOA_5 5 LED_Status 5 N C 6 GPIOC_0 6 N C 7 GPIOC_1 7 N C 8 GPIOC_2 8 N A P19 9 GPIOC_3 9 N A P23 10 RESET CHIP_EN 10 N A P21 11 GPIOE_2 11 N A P20 12 SW_ WPS GPIOE_1 12 N C 13 SW_Default GPIOE_3 13 BEEP GPIOE_4 14 GND 14 3 3V 15 5Vdc 15 GND Remark SW 200M J1 mapping to Aport 213 J7 S...

Page 14: ...us as following WiFi Mode Status LED indicator WiFi State Station Off Disconnect Always Light on BBD Connected AP Blinking every 2sec default Running RS 232 422 485 Serial Port LED indicator dual color It keeps light on after serial port is ready While the data transmission at the serial ports RXD in color Green and TXD in color Yellow Serial Console Serial Console LED indicator dual color While t...

Page 15: ...ub 9pin Male is shown as following table Pin No RS 232 RS 422 RS 485 1 DCD TX 2 RX TX 3 TX RX DATA D 4 DTR RX DATA D 5 GND GND GND 6 DSR 7 RTS 8 CTS 9 Enable Disable Termination resistor for RS 485 The Aport 213 equips on board 120Ohm termination resistor for each RS 485 port Default setting is disable termination resistor In order to enable termination resistor please remove the top cover of the ...

Page 16: ...imeout after minutes if there is not any activity WPS mode WiFi Protected Setup by Press 1sec and release button Simple Config mode only for Android smart phone operating by Press 3sec and release button Status LED will blink while function SW2 RTD Restore to Default SW3 Reset button 4 6 Switch SW4 Set the SW4 setting to RS 232 mode and pin definition of Aport 213 serial port is as follow SW Key 1...

Page 17: ... PIN Assignment 1 UART Log out GPIOB_0 1 UART0_IN GPIOA_6 2 UART Log in GPIOB_1 2 UART0_OUT GPIOA_7 3 I2C SCL GPIOB_2 3 UART0_RTS GPIOA_3 4 I2C SDA GPIOB_3 4 UART0_CTS GPIOA_5 5 Status_LED 5 N C 6 SW_4 GPIOC_0 6 N C 7 SW_3 RS 485_EN 7 N C 8 SW_2 RS 422_EN 8 N A P19 9 SW_1 RS 232_EN 9 N A P23 10 SW3_RESET 10 N A P21 11 GPIOE_2 11 N A P20 12 SW1_ WPS GPIOE_1 12 N C 13 SW2_RTD GPIOE_3 13 BEEP GPIOE_4...

Page 18: ...ok or PC via web browser without any software installation 5 1 Connect Aport 213 through browser After well connected by choosing the WiFi SSID APORT 213 at WiFi table that Aport 213 can be configured easily through browser like Chrome IE Firefox The following is default information for 1st login IP 192 168 0 3 Username admin Password admin ...

Page 19: ...onfigure page as following 5 2 1 Basic Basic setting of Aport 231 includes of device name serial port parameters Serial to network parameters static IP DHCP setting After completed the setting click to save all parameters Click All information listing below will be restored to default ...

Page 20: ...Aport 213 User s Guide ARTILA 20 5 2 2 Advanced Advanced setting of firmware upgrade by choose an image file automatically event report export via email and Modbus settings ...

Page 21: ...213 User s Guide ARTILA 21 5 2 3 Security System access control and authority setting 5 2 4 WiFi WiFi parameters setting includes of network mode WEP encryption key setting and AES TKIP encryption key setting ...

Page 22: ...ws y u t sca y ur wire ess adapter a d easure etw r pr cessi g a d perati g 5 2 6 RTC RTC or NTP server for Aport 213 can be set via this configure also setting the date time daylight saving and time zone Three NTP server IP can be listed for time synchrony ...

Page 23: ...Aport 213 User s Guide ARTILA 23 5 2 7 Status Display all Aport 213 status 5 2 8 Logout Log out this configure table by press Logout at function column ...

Page 24: ... Aport 213 at Download page that shows the product series http www artila com download APORT APORT 213 You may also go for product category Industrial Communication Gateway At model APORT 213 click to download Artila Manager utility After downloaded Execute the file AXMR2W_RS232 to WiFi_Toolkit as an administrator for Windows utility installation 6 2 Connect Aport 213 After well connected by choos...

Page 25: ...s list The Menu Board contains the following tools Device Manager Enable you to manage Aport 213 remotely Virtual Serial Port Enable you to manage virtual serial ports on the host PC Device Monitor Enables you to monitor the status COM Port Terminal Supports RS 232 port terminals to make it easier for you to develop or test Aport 213 application 2 Settings Functions displays supported functions of...

Page 26: ...Search the devices which connected Device Setting Device configuration of network serial port WiFi HDCP and NTP Firmware Upfrade upgrade the firmware remotely Reboot Reboor the Device Restore Set device to default setting Web Browser Go to web browser configuration refer to Section 5 Configure via Web Browser ...

Page 27: ...settings of the selected virtual serial port When a virtual serial port is added successfully it will be added in the Virtual Serial Ports List and the following information is displayed Category Description Port ID The identification value of the virtual serial port Port Name The name of the virtual serial port Status The status of the virtual serial port Remote IP The IP address of the device se...

Page 28: ... Step2 On the COM Port Configuration dialog select an unused port number to assign to the new virtual serial port Then click the OK button to complete the add operation Step3 Click the Setting button to configure settings of the connection type IP address and listening port according to configuration of the targeted device After completed the setting click OK to save ...

Page 29: ...ice server You will see the update of the virtual serial port s status in both the Settings Functions and the Menu Board Warning When you click the Add button to add a virtual serial port and pop up a warning message refer to below figure you need to enable the administrator authority and restart the utility ...

Page 30: ...ndent on the flow control function of APORT 213 RS 233 to WiFi firmware If this function is enabled on virtual serial port driver and firmware both sides will add a 3 bytes header ahead of each egress WiFi packet and will strip off the 3 bytes header of ingress WiFi packet Connect at Windows Start Enable disable the automatic connection function at Windows start When this function is enabled the v...

Page 31: ... PC Before starting it needs a cable connection from COM port of Aport 213 to PC By following the previous steps to add a virtual port COM7 and connect Select COM Port Terminal It displays COM terminal 1 COM4 Aport 213 Serial Port and terminal 2 COM7 virtual port Be noted that Baud Rate and Data Bit must be setting the same parameter ...

Page 32: ...Press Open Port each successfully then it can be input idea information at right hand area for data transition Press Auto Test at Terminal 1 and Echo at Terminal 2 Terminal 1 will send characters automatically to Terminal 2 for testing ...

Page 33: ...s List it will be added in the Devices List and the following information is displayed Category Description NO Device server index in the list Query Status The device server s query status Device Name Device server name IP Device server IP address Modem Status The value of device server UART2 s Modem Status register Firmware Version Production firmware version Serial Port TX Count Device server UA...

Page 34: ...on Open Port opens the selected COM port Close Port closes the selected COM port Clear Log clears the console data Purge Buffer clears the data stored in COM port buffer Auto Test Enable disable sending test data Echo Enable disable echoing back received test data TX Interval ms The time interval to send out a test data TX Data Length The test data s length ...