background image

 

4

 

 

Always power off/unplug the fixture before removing any covers. 

 

Ensure that the power is turned off when connecting the fixture to the AC 

mains supply. 

 

Ensure that the fixture is electrically connected to earth (ground). 

 

Do not apply power if the fixture is in any way damaged. 

 

Do not immerse the fixture in water or liquid. 

   

Preventing burns and fire 

 

 

 

Install in a location that prevents accidental contact with the fixture. 

 

Install only in a well-ventilated space. 

 

Install at least 0.3 m (12 in.) away from objects to be illuminated. 

 

Install only in accordance with applicable building codes. 

 

Ensure a minimum clearance of 0.1 m (4 in.) around the cooling fans. 

 

Do not paint, cover or modify the fixture. 

 

Keep all flammable materials away from the fixture. 

 

Allow the fixture to cool for 15 minutes after operation, before touching it. 

 

CAUTION:  Exterior  surface  temperature  after  5  min.  operation  =  45  °C 

(113 °F). Steady state = 60 °C (140 °F). 

   

Avoid personal injury 

 

WARNING! 

Take measures to prevent burns and fire.

 

WARNING! 

Risk of electric shock.

 

 

13

10-50 

Dimmer curve 1 

51-101 

Dimmer curve 2 

102-152 

Dimmer curve 3 

153-203 

Dimmer curve 4 

204-249 

Dimmer curve 5 

250-255 

Dimmer curve 6 

10 

0-255 

Color temperature (Warm to Cool) 

 

12.

 

Control menu 

 

 

Display:

 

 

MENU 

To select the programming functions 

DOWN 

To go backward in the selected functions 

UP 

To go forward in the selected functions 

ENTER 

To confirm the selected functions 

 

Set    DMX Address Code 

1.

 

Press "

Menu

" to "Set DMX Address",and press "

ENTER

" keys to enter into 

2.

 

Show "Set DMX Address DMX Address:001",Press the "

UP

 and 

DOWN

keys to amended 

3

 

Press "

ENTER

" keys to save and Exit,Press the "

MENU

" Keys does not 

save and Exit

 

Summary of Contents for IP WASH 44

Page 1: ...re use This product manual contains important information about the safe installation and use of this projector Please read and follow these instructions carefully and keep this manual in a safe place for future reference IP WASH 44 44 RGBW 4IN1 LED WASH LIGHT ...

Page 2: ...factory All of the user should comply with warning item and manual any misuse cause of the damages are not included in our guarantee and also can not be responsible for any malfunction problem owing to ignore the manual TABLE OF CONTENTS 15 1 20 times second strobe 4 10 DMX channels 4 built in auto mode 6 Dimmer curve Construction 170 Tilt adjustment Cast aluminum body IP65 rating 2 x two quarter ...

Page 3: ...lay 13 Specification Light Source AC90 240V 50 60HZ 450W power consumption 44 x high power RGBW 4IN1 LEDs 10W 15W optional 50 000 hours expected lifetime 25 35 45 lens beam angle optional Control 0 100 32bit linear dimming 3 1 Dimension 2 Safety Informations This luminaries are multi environmental fixtures with an IP rating of 55 intended for professional use only They are not suitable for househo...

Page 4: ...ials away from the fixture Allow the fixture to cool for 15 minutes after operation before touching it CAUTION Exterior surface temperature after 5 min operation 45 C 113 F Steady state 60 C 140 F Avoid personal injury WARNING Take measures to prevent burns and fire WARNING Risk of electric shock 13 10 50 Dimmer curve 1 51 101 Dimmer curve 2 102 152 Dimmer curve 3 153 203 Dimmer curve 4 204 249 Di...

Page 5: ...om close range Take precautions to prevent injury due to falls when working at height For permanent installation ensure that the fixture is securely fastened to a load bearing surface with suitable corrosion resistant hardware For temporary installation with clamps ensure that the quarter turn fasteners are turned fully and secured with a suitable safety cable The cable must be approved for a safe...

Page 6: ...move the rubber feet from the floor stand base Fasten securely through the resulting holes with four corrosion resistant mechanical fasteners suitable for the location 11 Setting the DMX address The DMX address can be seen on the main screen To change the address setting press the up arrow to increase the address or the down arrow to decrease the setting When the desired address is displayed press...

Page 7: ...e flown above the ground Remove the floor stand base and rig the fixture to a support truss or structure using the supplied brackets and suitable clamps Fasten a safety cable not shown between the support structure and the attachment point on the fixture The safety cable must be able to bear at least 10 times the weight of the fixture The fixture can be tilted from 0 170 To adjust the tilt angle l...

Page 8: ...perate as master fixture to another fixture which then 9 becomes a slave fixture or an entire group of fixtures which then becomes slave fixtures The assigned slave fixture s will mimic the settings of the master fixture Use the Mode AutoSlip AutoSkip Scene menu to set your fixture as master fixture then other fixture set to DMX mode as slave fixture Setting a static color manually The fixture can...

Reviews: