background image

 

10

 

9.

 

Configuring the fixture for DMX control 

 

About DMX 

The fixture can be controlled using signals sent by a DMX controller on a 

number of channels (which varies depending on the DMX mode that has been 

set). 

The first channel used to receive data from a DMX control device is known as 

the DMX start address. Each fixture must have a DMX start address set. For 

example, if a fixture has a DMX address of 10 and it is in 4-channel DMX mode, 

then it uses channels 10, 11,12 and 13. The following fixture in the DMX chain 

could then be set to a DMX address of 14. If two or more DMX fixtures of the 

same type have the same DMX address, then they will mimic each other’s 

behaviour. Incorrect settings will result in unpredictable responses to the 

lighting controller. 

 
 
 
 
 

Setting the DMX address 

 

7

Two quarter-turn brackets are supplied with the fixture if it is to be flown above 

the ground. Remove the floor stand/base and rig the fixture to a support truss 

or structure using the supplied brackets and suitable clamps. 

 

Fasten a safety cable (not shown) between the support 

structure  and  the  attachment  point  on  the  fixture.  The 

safety cable  must be  able  to bear at  least  10  times  the 

weight of the fixture. 

 

The fixture can be tilted from 0° - 190°. To adjust the tilt angle, 

loosen the two tilt screws, one of each side of the fixture, tilt the 

fixture to the angle required and re-tighten the screws. 

 

CAUTION:

 If the fixture has been operating, always allow it to 

cool for 15 minutes before handling. 

 

6.

 

Connecting AC Power 

 

The fixture can operate on any 100–240 V, 50/60 Hz 

AC  mains  power  supply.  It  draws  approximately  2 

amps at full power. For permanent installation, have 

a qualified electrician wire the mains cable directly to 

a suitable branch circuit. 

The junction’s ingress protection (IP) rating must be 

suitable for the location. 

 

For  temporary  installation,  the  mains  cable  may  be  fitted  with  a  grounded 

connector intended for exterior use. 

WARNING! 

Always secure an elevated fixture with a safety cable as backup.

 

Summary of Contents for IP STROBE 648 RGB

Page 1: ...use This product manual contains important information about the safe installation and use of this projector Please read and follow these instructions carefully and keep this manual in a safe place for future reference IP STROBE 648 RGB 648 RGB 3IN1 LED STROBE BLINDER WASH LIGHT ...

Page 2: ...ee and also can not be responsible for any malfunction problem owing to ignore the manual TABLE OF CONTENTS 15 13 Specification Light Source AC90 240V 50 60HZ 450W power consumption 648 x 0 6W RGB 3IN1 LEDs 50 000 hours expected lifetime 120 fixed beam angle Control 2 row sections led each section can be control individually DMX512 Master Slave Auto Sound 3 9 12 DMX channels 0 100 32bit linear dim...

Page 3: ... 099 Sense Auto 2 Val xxx Color fade speed adjustment 001 099 Sense Auto 3 Val xxx Color pulse speed adjustment 001 099 Offset Correct RED Red color manual dimmer GREEN Green color manual dimmer BLUE Blue color manual dimmer WHITE White color manual dimmer DRIM Dimmer curve reference to CH9 TEMP Fixture temperature display 3 1 Dimension 2 Safety Informations This luminaries are multi environmental...

Page 4: ... 4 in around the cooling fans Do not paint cover or modify the fixture Keep all flammable materials away from the fixture Allow the fixture to cool for 15 minutes after operation before touching it CAUTION Exterior surface temperature after 5 min operation 45 C 113 F Steady state 60 C 140 F Avoid personal injury WARNING Take measures to prevent burns and fire WARNING Risk of electric shock 13 0 9 ...

Page 5: ...recautions to prevent injury due to falls when working at height For permanent installation ensure that the fixture is securely fastened to a load bearing surface with suitable corrosion resistant hardware For temporary installation with clamps ensure that the quarter turn fasteners are turned fully and secured with a suitable safety cable The cable must be approved for a safe working load SWL of ...

Page 6: ...he ground remove the rubber feet from the floor stand base Fasten securely through the resulting holes with four corrosion resistant mechanical fasteners suitable for the location 11 The DMX address can be seen on the main screen To change the address setting press the up arrow to increase the address or the down arrow to decrease the setting When the desired address is displayed press Enter to sa...

Page 7: ...stand base and rig the fixture to a support truss or structure using the supplied brackets and suitable clamps Fasten a safety cable not shown between the support structure and the attachment point on the fixture The safety cable must be able to bear at least 10 times the weight of the fixture The fixture can be tilted from 0 190 To adjust the tilt angle loosen the two tilt screws one of each side...

Page 8: ...becomes a slave fixture or an entire group of fixtures which then becomes slave fixtures The assigned slave fixture s will mimic the settings of the 9 master fixture Use the Mode AutoSlip AutoSkip Scene menu to set your fixture as master fixture then other fixture set to DMX mode as slave fixture Setting a static color manually The fixture can be configured to display a predefined and static color...