background image

 

6

4.

 

Preparing for installation 

 

Unpack the fixture and inspect it to ensure that it has not been damaged during 

transport. 

 

The  fixture  is  shipped  with  two  quarter-turn  brackets,  that  can  be  used  to 

mount the fixture at elevation. 

The fixture is IP55-rated, and is designed for use in wet locations. This means 

that it is protected from: 

 

Dust,  to  the  degree  that  dust  cannot  enter  the  fixture  in  sufficient 

quantities as to interfere with its operation. 

 

Lower pressure jets of water from any direction. 

 

When selecting a location for the fixture, ensure that: 

 

It is situated away from public thoroughfares and protected from contact 

with people. 

 

It is not immersed in water or exposed to high-pressure water jets. 

 

It has adequate ventilation. 

 

5.

 

Installation 

 

The fixture may be installed in any orientation, but if installed horizontally with 

a  downward  beam-angle,  water  can  potentially  pool  in  the  fan  wells.  Under 

normal operation the moisture will evaporate. However, in locations with high 

rainfall, you may wish to fabricate a rain shield above the fixture, or modify the 

position and orientation of the fixture to minimize pooling. 

 

For permanent installation on the ground, remove the rubber feet from the floor 

stand/ base.  Fasten securely through  the resulting holes with four

 

corrosion- 

resistant mechanical fasteners suitable for the location. 

 

 

11

 

The DMX address can be seen on the main screen. To change the address 

setting, press the up arrow to increase the address, or the down arrow to 

decrease the setting. When the desired address is displayed, press Enter to 

save the setting.   

Note that channel spacing is determined by the DMX mode. 

See the “DMX protocols” on page 13 for specific DMX control values. 

 

Setting the DMX mode 

Using the “DMX mode” menu available from the control panel, specify the DMX 

mode that provides the fixture controls that you require, confirm chosen mode 

by pressing ‘Enter’. 

 

10.

 

Cleaning 

 

To maintain optimal performance, regular cleaning is essential. Cleaning 

schedules will vary depending on the operating environment, and the 

installation should therefore be checked at frequent intervals within the first 

few weeks of operation to see whether cleaning is necessary. This procedure 

will allow you to assess cleaning requirements in your par- ticular situation. 

Clean the fixture using a soft cloth dampened with a solution of water and a 

mild detergent. Do not use products that contain solvents, abrasives or caustic 

agents for cleaning, as they can cause damage to both hardware, cables and 

connectors. 

 
 
 
 
 
 

Summary of Contents for IP STROBE 648 RGB

Page 1: ...use This product manual contains important information about the safe installation and use of this projector Please read and follow these instructions carefully and keep this manual in a safe place for future reference IP STROBE 648 RGB 648 RGB 3IN1 LED STROBE BLINDER WASH LIGHT ...

Page 2: ...ee and also can not be responsible for any malfunction problem owing to ignore the manual TABLE OF CONTENTS 15 13 Specification Light Source AC90 240V 50 60HZ 450W power consumption 648 x 0 6W RGB 3IN1 LEDs 50 000 hours expected lifetime 120 fixed beam angle Control 2 row sections led each section can be control individually DMX512 Master Slave Auto Sound 3 9 12 DMX channels 0 100 32bit linear dim...

Page 3: ... 099 Sense Auto 2 Val xxx Color fade speed adjustment 001 099 Sense Auto 3 Val xxx Color pulse speed adjustment 001 099 Offset Correct RED Red color manual dimmer GREEN Green color manual dimmer BLUE Blue color manual dimmer WHITE White color manual dimmer DRIM Dimmer curve reference to CH9 TEMP Fixture temperature display 3 1 Dimension 2 Safety Informations This luminaries are multi environmental...

Page 4: ... 4 in around the cooling fans Do not paint cover or modify the fixture Keep all flammable materials away from the fixture Allow the fixture to cool for 15 minutes after operation before touching it CAUTION Exterior surface temperature after 5 min operation 45 C 113 F Steady state 60 C 140 F Avoid personal injury WARNING Take measures to prevent burns and fire WARNING Risk of electric shock 13 0 9 ...

Page 5: ...recautions to prevent injury due to falls when working at height For permanent installation ensure that the fixture is securely fastened to a load bearing surface with suitable corrosion resistant hardware For temporary installation with clamps ensure that the quarter turn fasteners are turned fully and secured with a suitable safety cable The cable must be approved for a safe working load SWL of ...

Page 6: ...he ground remove the rubber feet from the floor stand base Fasten securely through the resulting holes with four corrosion resistant mechanical fasteners suitable for the location 11 The DMX address can be seen on the main screen To change the address setting press the up arrow to increase the address or the down arrow to decrease the setting When the desired address is displayed press Enter to sa...

Page 7: ...stand base and rig the fixture to a support truss or structure using the supplied brackets and suitable clamps Fasten a safety cable not shown between the support structure and the attachment point on the fixture The safety cable must be able to bear at least 10 times the weight of the fixture The fixture can be tilted from 0 190 To adjust the tilt angle loosen the two tilt screws one of each side...

Page 8: ...becomes a slave fixture or an entire group of fixtures which then becomes slave fixtures The assigned slave fixture s will mimic the settings of the 9 master fixture Use the Mode AutoSlip AutoSkip Scene menu to set your fixture as master fixture then other fixture set to DMX mode as slave fixture Setting a static color manually The fixture can be configured to display a predefined and static color...

Reviews: