Hardware Preparation and Installation
RTM-ATCA-9305 IO Installation and Use (10010926-05
)
30
If you integrate the RTM in your own non-Artesyn system, contact your local sales
representative for further safety information.
Table 2-1 Environmental Requirements
Requirement
Operating
Non-Operating
Temperature
+5ºC (41ºF) to +40ºC (104ºF)
(normal operation)
-40ºC (-40ºF) to +70ºC (158ºF)
This may be further limited by
installed accessories.
Temperature Change
+/- 0.25ºC/min
+/- 0.25ºC/min
Relative Humidity
5% to 95% non-condensing
according to Artesyn-internal
environmental requirements
5% to 95% non-condensing according
to Artesyn internal environmental
requirements
Vibration
0.1 g from 5 to 100 Hz and back
to 5 Hz at a rate of 0.1
octave/minute
5-20 Hz at 0.01 g
2
Hz
20-200 Hz at -3.0 dB/octave
Random 5-20 Hz at 1 m
2
Sec
3
Random 20-200 Hz at -3 m/Sec
2
Shock
Half-sine, 11 m/Sec, 30
mSec/Sec
2
Module-level packaging
Half-sine, 6 msec at 180 m/Sec
2
Free Fall
-
1,200 mm/all edges and corners
1.0 m (packaged)
100 mm (unpacked)
Product Damage
High humidity and condensation on surfaces cause short circuits.
Do not operate the product outside the specified environmental limits. Make sure the
product is completely dry and there is no moisture on any surface before applying power.
Summary of Contents for RTM-ATCA-9305 IO
Page 1: ...RTM ATCA 9305 IO Installation and Use P N 10010926 05 September 2015...
Page 6: ...RTM ATCA 9305 IO Installation and Use 10010926 05 6 List of Tables...
Page 8: ...RTM ATCA 9305 IO Installation and Use 10010926 05 8 List of Figures...
Page 18: ...RTM ATCA 9305 IO Installation and Use 10010926 05 Safety Notes 18...
Page 28: ...Introduction RTM ATCA 9305 IO Installation and Use 10010926 05 28...
Page 42: ...Hardware Preparation and Installation RTM ATCA 9305 IO Installation and Use 10010926 05 42...
Page 52: ...LEDs and I O Interfaces RTM ATCA 9305 IO Installation and Use 10010926 05 52...
Page 60: ...Functional Description RTM ATCA 9305 IO Installation and Use 10010926 05 60...
Page 62: ...Related Documentation RTM ATCA 9305 IO Installation and Use 10010926 05 62...
Page 63: ......