Multiple 1 GbE SGMII and 10 GbE XAUI ports routed to Zone 3 connectors for base and
fabric uplink channels on RTM
Stratum 3 Telecom clock options with master/slave sync and five inter-shelf sync
connectors on front panel along with 2 BITS/SSU front panel connectors
Synchronous Ethernet support
One AMC bay for application processor support
IPMC functionality for the board management by the Shelf Management Controller
1.2
Standard Compliances
This blade, when installed in a compliant shelf, meets the following standards.:
Table 1-1 Standard Compliances
Standard
Description
UL/CSA No. 60950-1
EN 60950-1
IEC 60950-1 CB Scheme
UL/CSA No. 60950-1
Legal safety requirements
ANSI T1.319-2002
NEBS GR-63-CORE
ANSI Fire Spread Criteria
AT&T Document ATT-TP-76200
Network Equipment Power, Grounding, Environmental,
and Physical Design Requirements
ETSI Acoustic Noise ETS 300 753
Class 3.1
ETSI acoustic noise requirements
ETSI Stationary Use: EN 300 019-2-3
Class 3.1
ETSI stationary use requirements (temperature-
controlled locations
ETSI Storage EN 300 019-2-1 Class
1.2
ETSI storage requirements in system level (not
temperature- controlled storage locations)
ETSI Transportation: EN 300 019-2-2
Class 2.3
ETSI public transportation requirement on system level
Telcordia GR-1089
Ports and Iitra-building lightning for telecommunication