Hardware Preparation and Installation
ATCA-7365-CE Installation and Use (6806800L73N
)
48
The blade provides two independent power inputs according to the AdvancedTCA
Specification. Each input has to be equipped with an additional fuse of maximum 90A located
either in the shelf where the blade is installed or the power entry module (PEM).
The power consumption has been measured using specific boards in a configuration
considered to represent the worst-case (with RTM-ATCA-7360 and SAS HDD, maximum
memory population, USB-Flash, SF-MEM persistent memory module) and with software
simultaneously exercising as many functions and interfaces as possible. This includes a
particular load software provided by Intel designed to stress the processors to reach their
theoretical maximum power specification.
Any difference in the system configuration or the software executed by the processors may
affect the actual power dissipation. Depending on the actual operating configuration and
conditions, customers may see slightly higher power dissipation, or it may even be
significantly lower. There is also a dependency on the batch variance of the major
components like the processor and DIMMs used. Hence, Artesyn does not represent or
warrant that measurement results of a specific board provide guaranteed maximum values
for a series of boards.
Summary of Contents for ATCA-7365-CE
Page 1: ...ATCA 7365 CE Installation and Use P N 6806800L73N May 2016 ...
Page 26: ...ATCA 7365 CE Installation and Use 6806800L73N About this Manual 26 About this Manual ...
Page 36: ...ATCA 7365 CE Installation and Use 6806800L73N Sicherheitshinweise 36 ...
Page 140: ...BIOS ATCA 7365 CE Installation and Use 6806800L73N 140 ...
Page 284: ...Replacing Battery ATCA 7365 CE Installation and Use 6806800L73N 284 ...
Page 287: ......