ILC205 Function Module Installation and Operations Manual
5
Installing the ILC205 Module
Installing the ILC205 Module
The ILC205 module and associated SFPs are hot swappable, enabling you to safely install them while power is
applied to the host chassis. Before you install the module, see the ILC205 data sheet for a detailed description
of the module specifications including environmental requirements that you must adhere to when installing
the module.
To install the ILC205 module in the host chassis (see
Figure 3)
, perform the following steps:
1. From the back of the chassis, remove the two screws that secure the blank tray to the unused function
module slot.
Use any available function module slot.
2. Slide the module into the chassis slot using the printed circuit board guide rails on either side of the slot.
3. Push the module in until it is firmly seated into the backplane and flush with the chassis.
4. Tighten the two mounting screws that secure the module to the chassis.
5. Install the Artel-approved SFPs in the module (handle on top as shown in
Figure 3
).
Push the SFP into the socket located on the right side of the function module until it is firmly seated into
the socket.
6. Insert a blank tray in any unused chassis module slots to maintain proper ventilation.
Figure 3.
ILC205 Module and SFP Installation
SFP
(handle on top)
Module
Mounting Screws
(2)
Summary of Contents for INFINITYLINK ILC205
Page 2: ...ii ILC205 Function Module Installation and Operations Manual...
Page 4: ...iv ILC205 Function Module Installation and Operations Manual...
Page 8: ...viii ILC205 Function Module Installation and Operations Manual...
Page 28: ...18 ILC205 Function Module Installation and Operations Manual...
Page 30: ...Index Index 2 ILC205 Function Module Installation and Operations Manual...
Page 31: ......