ARTE NIREAS Installation & User Manual Download Page 28

Ε

ΓΧΕΙΡΙ∆ΙΟ

 

ΕΓΚΑΤΑΣΤΑΣΗΣ

 

&

 

ΧΡΗΣΗΣ

  

WATER HEATING FIREPLACE 

| NIREAS 

 

27 |

 

Σελίδα

 

 

14.

 

W

ARRANTY

 

We grant a two year warranty for your new ARTE

®

 SOL fireplace. The warranty period begins on the day the fireplace is installed and tested by 

a qualified dealer. We also grant a one year warranty for all the electrical parts (if any are installed). 

Warranty  claims  become  valid  when  the  purchase  price  for  the  fireplace  has  been  paid  in  accordance  with  the  agreement  and  the 
warranty certificate has been completed and returned within thirty days to ARTE

®

 G. Karnoutsos & CO. 

If any of these conditions is not fulfilled the minimum warranty of six months applies. 

14.1.

 

Warranty terms

 

 

Proper installation by a qualified dealer  

 

The fireplace is operated in accordance with these operating instructions 

 

No continuous firing  

 

No overheating  

 

Regular maintenance / cleaning (at least once a year) 

 

There must be no modifications to the fireplace structure: these can cause malfunctions and permanent damage  

14.2.

 

Excluded from the warranty 

 

Wearing parts like gaskets, vermiculite panels and glass 

 

Smoke and soot damage 

 

Natural discoloration or deviating colors on the outer cladding 

 

Cracks in the combustion chamber that have no effect on the safe functioning of the ARTE

®

 

SOL fireplace 

 

Damage incurred through failure to follow these operating instructions 

 

Damage covered by an insurance policy or other agreement 

14.3.

 

Responsibility 

Upon  delivery  of  this  manual  ARTE

®

  declines  all  liabilities,  both  civil  and  penal,  for  any  accidents  that  may  derive  from  the  total  or  partial 

failure to comply with the specifications contained in it. 

ARTE

®

 also declines all responsibility resulting from an improper use of the appliance, incorrect use by the user, from unauthorized alterations 

and/or repairs, or the use of non-original or non-specific spare parts for this particular fireplace. 

14.4.

 

Emergency maintenance 

Emergency maintenance on the fireplace model to which this manual refers, must be carried out by qualified personnel. 

14.5.

 

Responsibility for installation 

It  is  not  the  responsibility  of  ARTE

®

  to  carry  out  the  work  needed  to  install  this  fireplace.  Such  works  are  entirely  up  to  the  installer  who  is 

requested to check the flue and air intake and to check if the installation solutions proposed are feasible. All applicable standards and local, 
national and European legislation in force in the country where the fireplace is installed must be respected. 

14.6.

 

Usage 

Use  of  the  appliance  is  subject  to  compliance  with  all  the  safety  standards  established  by  the  relevant  laws  in  force  in  the  place  of 
installation, in addition to the instructions contained in this manual. 

14.7.

 

Legal guarantee

 

The  user  may  only  make  use  of  the  legal  guarantee,  as  under  the  EEC  directive  1999/44/CE,  if  he  has  scrupulously  complied  with  the 
regulations indicated in this manual, and more specifically: 

 

To work always within the fireplace limits of use  

 

Maintenance must be constant and careful  

 

Only allow people who are capable and who have been suitably trained to use the fireplace  

Failure to comply with the instructions provided in this manual will invalidate the guarantee immediately 

 

In order for the warranty to be applicable, please 

fill out the form on this manual’s last page

 

Summary of Contents for NIREAS

Page 1: ......

Page 2: ...preparation 14 7 3 3 Combustion air intake 14 7 3 4 Power failure 14 7 3 5 Heating during seasonal change or in adverse weather conditions 15 7 4 Adjusting the combustion air 15 7 4 1 Adjusting the c...

Page 3: ...ced locally which creates local employment and more tax revenues stay in the province 2 2 Buying firewood Where can I get my firewood Regenerated ready to burn firewood can be purchased from dealers F...

Page 4: ...rewood Avoid wood that pops chestnut conifers such as cedar spruce and pine as they may damage your fireplace or the flue Pay attention to the size of the logs Good firewood must have been cut at leas...

Page 5: ...on its insulation In average the required heat output for a properly insulated room and with external temperature of 0 is 40 kCal h per m3 Taking into account that 1kW equals 860 kCal h an equivalent...

Page 6: ...omising the secure transfer of our products 4 1 Unpacking the fireplace 1 The product will be delivered on a wooden palette which is lined with wooden side panels and top panel Pic 4 1 1 2 Firstly rem...

Page 7: ...rs Do not use ANY fuel other than the recommended 5 4 Flue security instructions Prior to installing the fireplace ARTE the chimney sweep or a qualified technician should check the condition and opera...

Page 8: ...e inclination and the distance of the chimney from the ridge according to the following table Pic 5 4 2 3 Inclination RIDGE CHIMNEY DISTANCE MIN HEIGHT ABOVE THE RIDGE m H m 15 1 85 m 0 50 m OVER THE...

Page 9: ...must be placed on top of the trunk approximately 20cm from the ceiling The grille must always be installed as its purpose is to allow the heat that builds up inside the trunk to be released in the roo...

Page 10: ...ons referring to national and European standards The installation can be set into operation only after it has been tested by a qualified inspector Prior to installing the new fireplace please contact...

Page 11: ...d only in case of heater map installation 13 Water pump 14 Automatic filling valve 15 Closed expansion tank 16 ARTE NIREAS fireplace 9 Fan coil heater 10 Radiator or heater mat 11 Temperature pressure...

Page 12: ...r map installation 13 Water pump 14 Automatic filling valve 15 Closed expansion tank 16 ARTE NIREAS fireplace 9 Fan coil heater 10 Radiator or heater mat 11 Temperature pressure gauge 12 Three way val...

Page 13: ...ge 12 Three way valve for by pass 5 Drainage 6 Water distribution box 7 Buffer tank 8 Hot water 1 Automatic vent valve 2 Thermometer 3 Overheating safety valve 4 ARTE NIREAS fireplace ARTE NIREAS fire...

Page 14: ...uipped with the following control systems 7 2 About ARTE NIREAS fireplace The fireplace that you just received is a device designed to offer excellent heating distribution in the area with a very high...

Page 15: ...ith external fresh air When you open the door of the combustion chamber for adding firewood there should be no pressure difference between outdoor and indoor air in the room so it is good to keep the...

Page 16: ...r intake damper To prevent overheating they are equipped with a sensor positioned in the copper tube Table 7 2 2 Line 10 of the water jacket where in the case of overheating the device closes the supp...

Page 17: ...o an outage longer than that an uninterruptible power supply device can be used UPS For safety reasons if the regulator is not receiving power the damper closes completely and is automatically placed...

Page 18: ...nages the DHW and HC pumps The table below presents the different modes of operation of the fireplace ICON MODE DESCRIPTION ON The air intake damper is automatically adjusted in order to stabilize the...

Page 19: ...e operation of another heat source e g gas boiler or to command an additional pump or solenoid when the water temperature reaches a predetermined value 7 4 2 5 TIME ADJUSTMENT screen The screen displa...

Page 20: ...the top of the buffer tank T1 The screen displays WAW temp sensor T1 damaged If the sensor is not installed the alarm is not activated Failure of the sensor on the bottom of the buffer tank T2 The scr...

Page 21: ...in order for enough air for combustion to enter Close the door again once the wood ignites 7 Ensure there is adequate air supply oxygen to maintain the flame clear and powerful when you reduce the amo...

Page 22: ...scharged directly through the draft of the flue to the exterior and not in the heating area ARTE NIREAS chamber manages to provide the maximum secondary combustion performance An automatic air intake...

Page 23: ...be stored in a closed container until cooled down or buried on the ground or dispersed somewhere 10 2 2 Glass ARTE NIREAS fireplace has a single ceramic glass in the window of the combustion chamber i...

Page 24: ...lean the flue chimney all the way from the fireplace to the flue end point above the house A good practice is to clean the flue after each operating season and to inspect it prior to the start to ensu...

Page 25: ...ttles inside the fireplace it forms rust which expands the more it settles This can cause excessive pressure on the fireplace joints thus causing damage NOTE It is recommended to thoroughly clean the...

Page 26: ...WATER HEATING FIREPLACE NIREAS 25 12 DIMENSIONS...

Page 27: ...Device dimensions W x D x H cm 77 5 50 128 Combustion chamber dimensions W x D x H cm 60 32 42 Flue draft Pa 12 Heated area m2 55 200 Weight kg 208 External air inlet The section must be increased by...

Page 28: ...artial failure to comply with the specifications contained in it ARTE also declines all responsibility resulting from an improper use of the appliance incorrect use by the user from unauthorized alter...

Page 29: ...INSTALLATION USER MANUAL WATER HEATING FIREPLACE NIREAS 28 Page NOTES S N S N...

Page 30: ......

Reviews: