TECHNICAL SPECIFICATIONS
UNITS
* Total heat output
Kcal/h
20889
kW
24.29
* Total heat output in water
Kcal/h
15738
kW
18.3
Water tank capacity
lt
36
Maximum operating pressure
bar
2.5
Recommended hourly consumption of firewood
Kg/h
7
Heat output
%
78.5
Exhausts temperature
°C
231
CO emissions
(by providing O
2
at 13%)
%
0.1
Yield range
(minimum - maximum)
kW
10.5 - 30
Fuel
-
Wood, Briquette
Device dimensions (W x D x H)
cm
77.5/50/128
Combustion chamber dimensions (W x D x H)
cm
60/32/42
Flue draft
Pa
12
Heated area
m
2
55 - 200
Weight
kg
208
External air inlet.
The section must be increased by 20% for each additional meter after 1 m
cm
Ø10
Smoke outlet diameter
cm
Ø18
**Minimum flue height
m
4
Minimum heating area
m
2
55
* The fireplace operates with intermittent combustion technology. In this case intermittent combustion means the normal use of the fireplace, e.g. new
firewood is added as soon as the previous are burned, forming a sufficient amount of cinder.
**
The internal section of the flue must be increased by 10% per 500m altitude above sea level.
Table 13.1