SLA-2 SPECIFICATIONS 

 
 
Dimensions 

 

  1.75”H x 19.0” W x 13.5”D 

Weight  

 

19.8 

lbs., 

9.0kg. 

Input Connections 

 

  XLR,EUROBLOCK (balanced),      

                                                        ¼”TRS(balanced/unbalanced) 
Output Connections 

 

  Multi-Way Binding Post 

Input Impedance              

  44k ohms (balanced) 

                                                       22k ohms (unbalanced) 
Input Sensitivity 

 

  1V for Full Power Output into 8 ohms 

Stereo Output Power, 8 ohms    200Watts RMS per Channel, 
Stereo Output Power, 4 ohms    280Watts RMS per Channel 
Bridged Output Power, 8 ohms    560Watts RMS mono 

         Stable into:                                     2 Ohms (stereo) 

                                                      4 Ohms (mono) 
CMRR 

 

  >60dB (typical @ 1kHz)  

Frequency Response   

  10Hz to 40kHz, +/- .5dB 

         Hum and Noise 

 

  >100dB below clipping 

         Total Harmonic Distortion (THD)  <0.05% (typical) 

Slew Rate 

 

  >20V/uS  

Damping Factor 

 

  >100 

Transformer Type 

 

  Toroidal 

Power Requirements   

    100VAC 50Hz 1000 WATTS (max.) 

                                                       120VAC 60Hz 1000 WATTS (max.) 
                                                       220VAC 50Hz 1000 WATTS (max.) 
 

 

    230VAC 50Hz 1000 WATTS (max.) 

 

 

    240VAC 50Hz 1000 WATTS (max.) 

Export units configured for country of 
destination. 

 
ART maintains a policy of constant product improvement. ART reserves the right to 
make changes in design or make additions to or improvements upon this product 
without any obligation to install same on products previously manufactured. Therefore, 
specifications are subject to change without notice. 

 

Applied Research & Technology, a Division of Yorkville Sound 

215 Tremont Street 
Rochester, NY 14608 USA 
(585) 436-2720 
(585) 436-3942 (FAX)  
www.artproaudio.com 

© 2004 Applied Research & Technology  

Summary of Contents for SLA-2

Page 1: ...icators 7 Power Switch 7 Channel Attenuators 7 Signal LED Indicator 7 Clip LED Indicator 7 Protect LED Indicator 8 Rear Panel Connections 9 Input Jacks 9 XLR Input Jacks 10 EuroBlock Barrier Strip 10...

Page 2: ...obstruct the ventilation slots or position the unit where the air required for ventilation is impeded If the unit is to be operated in a rack case or other furniture ensure that it is constructed to...

Page 3: ...er are less than 4 Ohms Using one speaker per channel it must be rated at 4 or more Ohms Using two speakers per channel they must each be rated at 8 Ohms or greater When in bridge mode the speaker sho...

Page 4: ...delivers the power you need for professional and project studio monitoring FEATURES Extremely low noise discrete linear design 200 Watts Channel 8 Ohms 560 Watts Bridged Mono 8 Ohms Toroidal transfor...

Page 5: ...mountable unit is properly ventilated and the SLA 2 is no exception AC POWER HOOKUP The SLA 2 has an internal power supply designed to operate at 120 VAC 50 to 60 Hz Units manufactured for use outsid...

Page 6: ...s included with the SLA 2 Simply set the channel attenuators to the desired gain settings then press the knobs into the chassis until they lock in their recessed position Then remove the two small phi...

Page 7: ...lockwise there is no attenuation of volume As the attenuation amount increases by turning counterclockwise the volume is reduced Full attenuation is at infinity The attenuators are calibrated in dB SI...

Page 8: ...ode the output signal to the speakers will be muted channel specific If there is a fault condition at the speaker outputs due to a severe load or short the LED will light until the fault is removed Th...

Page 9: ...lifier Balanced connections are recommended for cable runs longer than 20 feet For cable runs under 20 feet the unbalanced connections can be used You may also use the two different types of input cab...

Page 10: ...o Mode and Bridged Mono Mode Make sure that power is off and that your speakers are wired appropriately when changing this mode OUTPUT BINDING POST The SLA 2 Outputs are multi connection jacks You can...

Page 11: ...n advanced thermal dependent fan assisted convection cooled system The SmartFan system is dependent upon the internal ambient temperature inside the unit and runs at two different levels The SmartFan...

Page 12: ...material directly into the inputs and set the output controls to provide an appropriate level into the next stage of your system and an excellent choice for this are the ART SLM 1 Studio Linear Monit...

Page 13: ...rasonic network decouples RF from the output and helps keep the amplifier stable with reactive loads The SLA 2 s heatsinks do most of the work in getting heat away from the amplifier in normal studio...

Page 14: ...sions This warranty does not apply in the event of misuse or abuse of the product or as a result of unauthorized alterations or repairs This warranty is void if the serial number is altered defaced or...

Page 15: ...er or questions regarding technical assistance or repairs Customer Service hours are 9 00 AM to 5 00PM Eastern Time Monday through Friday 4 Pack the unit in its original carton or a reasonable substit...

Page 16: ...al Harmonic Distortion THD 0 05 typical Slew Rate 20V uS Damping Factor 100 Transformer Type Toroidal Power Requirements 100VAC 50Hz 1000 WATTS max 120VAC 60Hz 1000 WATTS max 220VAC 50Hz 1000 WATTS ma...

Reviews: