Characterization register map 

Register 

Name 

Vers. 

Centr. 

EVO 

EASY 

Description 

801 

INVTYPE 

1.2.5 

1.0.0

 

Lower nibble: HHV/HV/Standard Standard=1, HV=2, HHV=3 
bit 15 (0x8000) = 1 -> Transformer. 
bit 14 (0x4000) = 1 -> Easy/Evo Model 
bit 13 (0x2000) = 1-> Battery charger 

802 

AC_PRO 

1.2.5 

No 

Active probes, lower nibble, bit = 1, active probe  

803-818 

P1_UNIT 

1.2.5 

No 

Probe #1 identification string 

819-834 

P2_UNIT 

1.2.5 

No 

Probe #2 identification string 

835-850 

P3_UNIT 

1.2.5 

No 

Probe #3 identification string 

851-866 

P4_UNIT 

1.2.5 

No 

Probe #4 identification string 

867 

P1_MAX 

1.2.5 

No 

Maximum value of probe #1 

868 

P2_MAX 

1.2.5 

No 

Maximum value of probe #2 

869 

P3_MAX 

1.2.5 

No 

Maximum value of probe #3 

870 

P4_MAX 

1.2.5 

No 

Maximum value of probe #4 

871 

KPV_AC 

1.2.5 

No 

Value of Kpv/Ac (%) 

DC-box register map 

Register 

Name 

Vers. 

Centr. 

EVO 

EASY 

Description 

901 

NUM_DC 

1.2.5 

No 

Number of Dc-box configured.

13

 

902 

DC_A1M1 

1.2.5 

No 

First current of first module

14

 (0.1A units) 

903 

DC_A2M1 

1.2.5 

No 

Second current of first module (0.1A units) 

… 

… 

1.2.5 

No 

… 

909 

DC_A8M1 

1.2.5 

No 

Eight current of first module (0.1A units) 

910 

DC_A1M2 

1.2.5 

No 

First current of second module (0.1A units) 

… 

… 

1.2.5 

No 

… 

917 

DC_A8M2 

1.2.5 

No 

Eight current of second module (0.1A units) 

918 

DC_A1M3 

1.2.5 

No 

First current of third module (0.1A units) 

… 

… 

1.2.5 

No 

… 

925 

DC_A8M3 

1.2.5 

No 

Eight current of third module (0.1A units) 

926 

DC_A1M4 

1.2.5 

No 

First current of fourth module (0.1A units) 

… 

… 

… 

 

… 

933 

DC_A8M4 

1.2.5 

No 

Eight current of fourth module (0.1A units) 

934 

DC_ALM1 

1.2.5 

No 

Alarms of first module

15

 

935 

DC_ALM2 

1.2.5 

No 

Alarms of second module 

936 

DC_ALM3 

1.2.5 

No 

Alarms of third module 

937 

DC_ALM4 

1.2.5 

No 

Alarms of fourth module 

938 

DC_W1M1 

1.2.5 

No 

First weight of first module (%) 

939 

DC_W2M1 

1.2.5 

No 

Second weight of first module (%) 

… 

 

 

 

 

945 

DC_W8M1 

1.2.5 

No 

Eight weight of first module (%) 

946 

DC_W1M2 

1.2.5 

No 

First weight of second module (%) 

… 

 

 

 

 

953 

DC_W8M2 

1.2.5 

No 

Eight weight of second module (%) 

954 

DC_W1M3 

1.2.5 

No 

First weight of third module (%) 

… 

 

 

 

 

961 

DC_W8M3 

1.2.5 

No 

Eight weight of third module (%) 

962 

DC_W1M4 

1.2.5 

No 

First weight of fourth module (%) 

… 

 

 

 

 

969 

DC_W8M4 

1.2.5 

No 

Eight weight of fourth module 

                                                

13

 The number of modules ranges from 1 to 4. The maximum number of measures is 32, 8 for each module.  

14

 

If the value is positive, it’s a valid measure. If the value is 0xFFFF, the measure belongs to a non-configured 

module; if the measure belongs to a configured module, but it’s in timeout, the value is 0xFEFE. 

15

 If the value is zero, there are no alarms on the corresponding module. If the value is different from zero, 

please contact Service. 

Summary of Contents for NETMAN204 SOLAR

Page 1: ......

Page 2: ...L __________________________13 CONFIGURATION VIA VNC ________________________________________________15 StringBox_______________________________________________________________ 15 Inverter____________...

Page 3: ...___ 34 Daily Data register map ___________________________________________________ 34 Characterization register map ______________________________________________ 35 DC box register map_______________...

Page 4: ...nored Information Provides notes and useful suggestions for the User SAFETY This part of the manual contains SAFETY precautions that must be followed scrupulously The device has been designed for prof...

Page 5: ...ferent material of which the packaging is made and dispose of all material in compliance with applicable standards in the country in which the product is used Disposing of the product The device conta...

Page 6: ...erter can therefore be integrated easily into small medium and large sized networks The device also records inverter values and events in history log archives To view historical data you can use the S...

Page 7: ...Solar is receiving or transmitting data packets Right LED SOLID GREEN NetMan 204 Solar is connected to a network operating at 100 Megabits per second Micro USB port NetMan 204 Solar doesn t currently...

Page 8: ...nds and then release it Users It is possible to access to NetMan 204 Solar with the following users Username Default password Privileges ftpuser arosftp This is the FTP user that can access the log fi...

Page 9: ...ork protocol used for file exchange NetMan 204 Solar uses this protocol for 1 download of files of the inverter values and events history log archive 2 firmware upgrade using SirioDataControl software...

Page 10: ...instant power in KW 4 Active instant power in KW 5 External measure 6 Inverter module temperature in Celsius 7 Daily energy in KWh 8 Grid frequency in Hz 9 Grid phase R instant power in W 10 Grid phas...

Page 11: ...previously Connect the device to the network by means of connector RJ 45 see Specifications for the cabling of the network cable STRING BOX Open the StringBox with the specific key Insert NetMan 204...

Page 12: ...your PC IP address to the same network Install the free SirioDataControl software and simply change the IP address The details will follow in this section This method can be used to change the networ...

Page 13: ...After installation of SirioDataControl connect your pc and the NetMan 204 Solar to the same network and run SirioDataControl Depending on if there are other inverters StringBox or not in the network...

Page 14: ...Gateway DNS1 and DNS2 DNS Domain Name Server UDP port leave as 33000 if you don t know what to do VNC port default 5900 FTP PASV lower upper port leave as default values if you don t know what to do N...

Page 15: ...user will be prompted with a window asking a password The default password is secret the password can be changed StringBox The StringBox shows only the configuration of IP address and relative parame...

Page 16: ...ate in This last parameter allows the user to balance the power given by solar panels and the effective power the inverter can manage to deliver The Second button allows the user to change Administrat...

Page 17: ...This value can be zeroed with the Zero button to start counting from the beginning again The user can change date time with the upper button on the right Hitting the Apply button on the upper right co...

Page 18: ...rom an external source Hitting the first upper button the user can change the network parameters as seen here The user can choose DCHP or a static IP configuration Please note that invalid addresses w...

Page 19: ...virtual screen function The use of the UDP FTP settings is straightforward the ftp NAT data ports has to be set in those cases where the user router has to be configured with NAT to allow PASV mode fr...

Page 20: ...n Apply button is present to confirm the settings Before to do so it s better to try to test the email settings with the second button A text with OK or KO should appear just below this second button...

Page 21: ...es each second so that the slave inverters can almost instantly adapt to the conditions required To activate the Power Reduction Function the user has to select Power Reduction checkbox and hit the Ap...

Page 22: ...f messages if e mail settings are correctly configured If you want to activate a function just press the leftmost button just as in the following screen In this example a mail will be sent to the conf...

Page 23: ...ide of the screen and will drive the user to the following screen This schematic view shows most of the significant values as seen from the inverter In the top right of this screen it s possible to pu...

Page 24: ...ser can hit the second button from top and he she gets the following screen From here the user can view log data upper button or manage log data having the means to delete undesired yearly data from p...

Page 25: ...plete because still not present The user can choose a different day using the Calendar button or can send the snapshot of the graph with the e mail button on the right The user can also drag the mouse...

Page 26: ...right side of the main page leads the user to the following screen On this screen the user will find when available The total energy produced by the inverter The total hours of operation The actual o...

Page 27: ...board firmware version The free RAM and flash memory occupancy in Kb and Touching the center of the screen brings the user to another screen This screen gives the user more info on the communications...

Page 28: ...he user should choose the update file and hit the Open button the file will be transferred to the NetMan 204 Solar board After the update the board will reboot The user should be careful to choose the...

Page 29: ...Read holding registers Read input registers Registers read All 6 0x06 Write single register Register write single Power reducer commands 16 0x10 Write multiple registers Registers write multiple Powe...

Page 30: ...high 15 Test Fail Self test failed 14 Temperature Fail Overtemperature 13 Reserved Reserved 12 Bus Fail DC bus fail 11 GFCI Fail Ground dispersion current is too high 10 No Utility Grid voltage not pr...

Page 31: ...0 Total output energy high register 0 1 KWh units 0 1KW Hr 32 E Total L 1 2 5 1 0 0 Total output energy low register 0 1KW Hr 33 h Total H 1 2 5 1 0 0 Operation hours high register Hr 34 h Total L 1...

Page 32: ...Firmware version example 01 00 30h 31h 2Eh 30h 30h 89 96 Serial number 1 2 5 1 0 0 97 104 Model Name 1 2 5 1 0 0 105 112 Manufacturer 1 2 5 1 0 0 Command register map Register Name Vers Centr EVO EAS...

Page 33: ...0 Ramp up of power gradient 0 100 0 100 6 147 RD 1 2 5 1 0 0 Ramp down of power gradient 0 100 0 100 6 148 BP 1 4 1 No Battery power 0 200 7 149 157 How power reducing is managed by Modbus The procedu...

Page 34: ...unit 203 LOAD_POWER_3 1 3 3 1 0 0 Autoconsumo kit phase 3 100W unit Daily Data12 register map Register Name Vers Centr EVO EASY Description 501 DAILY 1 1 2 5 1 0 0 First value of average power of the...