Date/Time register map
Register
Name
Vers.
Centr.
EVO
EASY
Description
161
YEAR
1.2.6
1.0.0
Year
9
162
MONTH
1.2.6
1.0.0
Month
163
DAY
1.2.6
1.0.0
Day
164
HOUR
1.2.6
1.0.0
Hour
165
MINUTE
1.2.6
1.0.0
Minute
166
SECOND
1.2.6
1.0.0
Second
These
values can be written with function 0x10 only; they can’t be read
10
.
Autoconsumo
11
register map
Register
Name
Vers.
Centr.
EVO
EASY
Description
201
LOAD_POWER_1
1.3.3
1.0.0
Autoconsumo kit, phase 1 (100W unit)
202
LOAD_POWER_2
1.3.3
1.0.0
Autoconsumo kit, phase 2 (100W unit)
203
LOAD_POWER_3
1.3.3
1.0.0
Autoconsumo kit, phase 3 (100W unit)
Daily Data
12
register map
Register
Name
Vers.
Centr.
EVO
EASY
Description
501
DAILY-1
1.2.5
1.0.0
First value of average power of the current day (10W unit)
…
…
…
703
DAILY-
203
1.2.5
1.0.0
Last value of average power of the current day (10W unit)
Every register contains the average power (on 5 minutes), starting from 5:05 up to 21:55.
9
In the form 0014 for 2014.
10
Date/time values must be written in a single write. Date/time are applied instantly.
11
“Autoconsumo” is a word that refers to a set of rules of the spanish market; using an external measure in a
special kit as a reference, the inverter can deliver only the power requested by the load.
12
Modbus/TCP only