11
Air Tube Connection on Air Duct
CORRECT
CORRECT
INCORRECT
Tube has a pocket, this part
will fill up with oil.
Best practice when installing in an AHU is to place the hose guide after the heating and
cooling coils. If this is not possible, the scent output can pass over hot water, steam,
chilled water, and DX coils.
Open gas flames should absolutely be avoided. If installation must be over gas
heated coils or open gas flames, contact AromaTech Technical Support.
The best location for the Scent Machine is below the Scent Point. The air tube should run
upward as short a distance as possible, and NEVER MORE THAN 3 FEET. If an upward air
tube run is not possible, care should be taken to support the hose to prevent sagging or
any low spots. This is to avoid any possibility of condensation and liquid collection which
will block the scent output. Give the air tube an upward slant along its run
(See image below)