The performance of these refrigerated cabinets was determined through tests conducted in
compliance with standard:
-
EN ISO 23953:2012 in environmental conditions corresponding to climatic class 3
(25 °C , 60% U.R.) see table:
Environmental climatic classes as per UNI EN ISO 23953
4. Identification - Nameplate (Fig. 2)
:
On the display cases, the matriculation plate is on the back of the cabinet. For semi-verticals, the
plate is on the left, on the back:
1
Manufacturer’s name and address
2
Name and length of the cabinet
3
Cabinet code number
4
Cabinet registration number
5
Power supply voltage
6
Power supply frequency
7
Max. absorbed current
8
Electrical power absorbed at steady state during refrigerating phase (fans + hot lighting)
9
Electrical power absorbed at steady state during defrosting phase (heating el hot cables
+ fans + lighting)
10 Illuminating power (where applicable)
11 Useful display surface
12 Type of refrigerating fluid used in the appliance
13 Mass of refrigerating gas loaded in each individual appliance (only for cabinets with incorporated
motor)
14 Environmental climatic class and reference temperature
15 Class of protection against humidity
16 Manufacturing job number of the cabinet
17 Manufacturing order number of the cabinet
18 Manufacturing year of the cabinet
In case of technical service request, please communicate the following information for the
identification of the cabinet:
- products name
(Fig. 2 - 2);
Article 3 section 3 of Directive
CEE 97/23 (PED)
does not apply to these cabinets.
Climatic Class of the
testing chamber
Dry bulb temp. Relative Humidity
Dew point
Weight of water vapour in
dry air
°C
%
°C
g/kg
0
20
50
9,3
7,3
1
16
80
12,6
9,1
2
22
65
15,2
10,8
3
25
60
16,7
12,0
4
30
55
20,0
14,8
6
27
70
21,1
15,8
5
40
40
23,9
18,8
7
35
75
30,0
27,3
8
23,9
55
14,3
10,2
The weight of water vapor in dry air is one of the main points that affect the performance and
power consumption of the cabinets
Declaration of
conformity
A copy of the conformity statement is annexed to the cabinet
If you lose the original copy of the Declaration of Conformity supplied with
the cabinet, download a copy by filling out the form available on the internet
addresses:
- for Italy: http://www.arneg.it/conformita/it
- overseas: http://www.arneg.it/conformita/en