1. Introduction - Manual purpose/Field of application
This instruction manual is for the refrigeration unit line
Pelican
.
The following information aims to provide instructions with regard to:
Unit use - technical characteristics - installation and assembly - information for users - maintenance
work.The manual should be considered part of the unit and must be kept for its entire working life.
The manufacturer is relieved from all liability in the following situations:
Improper use of the unit - incorrect installation, not completed in accordance with the regulations speci-
fied - electrical supply flaws - serious lack of maintenance - unauthorised alterations and work - use of
non-original spare parts - partial or complete lack of compliance with the instructions.
The manual must be available to operators and maintenance staff for consultation at all times. In the
event of transfer to third parties, it must be delivered to the new user or owner, duly informing the sup-
pliers in a timely manner.
If lost of damaged, please contact the supplier.
Anyone using this unit must read this manual.
Note:Electrical appliances can be dangerous to health. Current laws and regulations must be
applied during installation and use.
2. Presentation - Intended purpose (Fig. 1)
The refrigeration unit line
Pelican
consists of vertical wall display units with remote condenser unit,
perfect for the storage and self service sale of frozen foods and ice cream.
The cabinet consists of two independent units: a lower cabinet (tank) fitted with sliding glass doors that
allow for significant energy savings and better food storage, and an upper, multi-shelf cabinet (super-
structure) that is closed by leaf doors to the front.
The two parts are equipped with their own evaporator and separate air control system.
3. Standards and certifications, conformity statement
All models of refrigerated cabinets described in this manual and belonging to the line:
Pelican
meet the essential requirements concerning safety, health at the workplace and protection
required by the following European Directives:
The performance of these refrigerated cabinets was determined through tests conducted in com-
pliance with standard:
- EN ISO 23953:2012 in environmental conditions corresponding to climatic class 3 (25 °C , 60% U.R.)
see table:
Environmental climatic classes as per UNI EN ISO 23953
Directive
Harmonised standards applied:
Machinery Directive - 2006/42/CE
EN ISO 14121; EN ISO 12100-1; EN ISO 12100-2; EN 378-2;
EN 378-3; EN 378-4; EN 60079-10-1
2004/108/CE Electromagnetic
Compatibility
EN 61000-3-2; EN 61000-3-12; EN 55014-1; EN 55014-2
2006/95/CE Low Voltage
EN 60335-1; EN 60335-2-89/A2
RoHs Directive 2011/65/CE;
(restricted use of certain hazardous
substances in electrical and electronic
equipment)
EN 50581
European Regulation
EC-1935/2004
(on materials intended for contact with
the goods)
EN 1672-2
Article 3 section 3 of Directive
CEE 97/23 (PED)
does not apply to these cabinets.
Climatic Class of the
testing chamber
Dry bulb temp. Relative Humidity
Dew point
Weight of water vapour in
dry air
°C
%
°C
g/kg
0
20
50
9,3
7,3
1
16
80
12,6
9,1
2
22
65
15,2
10,8
3
25
60
16,7
12,0
i