41
Pictures for illustrating purposes only
Before putting your humidifier in operation,
please make sure that your installation be
in conformity with the manufacturer’s
technical specifications.
Open the water valve of the main water line.
Make sure that terminals 1 & 2 are jumped (s.a. page
39) otherwise the humidifier will not start up.
Switch on the main power supply contactors (voltage
and command).
The power-on light must be illuminated .
Switch on I the I/O (on/off) rocker switch.
The display will default to show the rate of steam
produced. You are in the user information menu.
As soon as the humidifier is prompted by the
regulator, the humidity sensor or the humidistat,
the contactor of the DIN rail turns on and the
power heating is on (the steam production LED
is illuminated) .
90 seconds after the humidifier is switched on, the
inlet valve opens and the cylinder/s is/are flushed with
water. The electrode plates then heat the water up
and after about 10 minutes (the heating time depends
on the model of humidifier and the water conductivity),
the humidifier steams up.
1
2
1
Humidifier identification label stuck under and shielded by
the front panel polycarbonate label.
This
identification
label
provides
the
following
information : EHU-750 model, unit serial number,
command voltage, power voltage, number of power
phases, and electrical power.
2
SERIES EHU-750 HUMIDIFIER
Setting up