PDS-32/42/46/47/52/55
www.
Armagard
.com
Installation Manual Page |
12
Toll Free (US):
1-866-434-0807
Call (UK):
0121-608-7210
5.
Use a Philips screwdriver to remove the steel lid that covers the PCB board and
place to one side.
6.
Connect the USB cable to your computer and the 3-pin internal connection to the
setup port (highlighted red) on the controller board; located on the left hand side,
third from the top (figure 2).
Figure 2
7.
Open up the terminal program mentioned from earlier and locate the setup port which
will appear as a COM port. Select the correct COM port from the drop down menu as
shown in figure 3 box 1. The correct COM port should be the last one on the list from
the drop down menu.
Figure 3
The default BAUD rate for setup is 115200 and the BAUD rate for info is 19200. These
can be selected from the pre-set figures shown in figure 3 box 2 above.
Note - A BAUD
is a unit used to express the speed of transmission of electronic signals, corresponding
to one information unit or event per second.
8.
Now click connect, highlighted in figure 3 box 3 above.