(ENGLISH) 

 

The following manual details the vital 
information and safety precautions needed 
for a safe installation of the Armagard PDS 
landscape enclosure. 

 

Due to the weight of your enclosure and for 
personal safety, it is recommended to refer 
to your company’s own health and safety 
heavy lifting procedures before moving the 
enclosure. 

 

All power must be switched off until the 
enclosure has been fully assembled and is 
ready to use. 

 

If your enclosure is for 

outdoor use, don’t 

attempt installation in bad weather; use 
correct lighting for optimum viewing 
conditions. 

 

Tools required for installation, Phillips 
Screwdriver, Drill and Sockets Kit or Wrench 

 

 

READ THIS MANUAL THROUGH BEFORE INSTALLING YOUR UNITS TO ENSURE CORRECT 

INSTALLATION AND THA

T YOU’RE COVERED UNDER WARRANTY. 

 

 

Electrical plugs, display bracket screws and 
wall plate bolts are not provided because of 
different customer setups. 

 

Armagard recommends that all enclosures 
should be securely attached to the wall 
before fitting the display to avoid any 
damage during lifting. 

 

Default thermostat settings can be found on 
page eleven. 

 

Because of its watertight seal, to lock an 
enclosure you have to push firmly against 
the door and then turn the key to lock. 

32”-55” 

INSTALLATION MANUAL 

YOUR WARRANTY AGREEMENT IS VOID 

if you perform any modifications on the 

enclosure, for example, drilling or penetrating any additional holes into the enclosure.

 

 

FOR BEST PRACTICE 

mount the enclosure using the recommended brackets to ensure 

integrity.

 

 

 

Summary of Contents for PDS 32

Page 1: ...tions Tools required for installation Phillips Screwdriver Drill and Sockets Kit or Wrench READ THIS MANUAL THROUGH BEFORE INSTALLING YOUR UNITS TO ENSURE CORRECT INSTALLATION AND THAT YOU RE COVERED...

Page 2: ...aling mount brackets LCD Mounting bracket x2 Reversible bracket x2 d parts Double ceiling bracket x 1 Single ceiling bracket x 1 1 PDS Enclosure x1 2 Keys x2 3 LCD Mounting Brackets x2 4 20mm Open Gro...

Page 3: ...nd display into the mains surge protector STEP 3 Carefully raise the enclosure up Figure1 and feed the surge protectors main power cable out through the gland plate at the back of the unit remove plat...

Page 4: ...halfway line of the unit STEP 10 Using the diagram shown in Figure4 fasten the brackets with the 4 or 6 screws suited to your LCD Display type Figure 3 Figure 4 STEP 9 For a balanced unit align the ce...

Page 5: ...ir curtain and the enclosure window any less and you risk insufficient cooling to keep the display working Figure6 Figure 55 Figure 6 0 59 INCHES NOTE For screen adjustment continue to STEP 16 STEP 14...

Page 6: ...g plate To Raise Loosen the screws and raise the interior bracket forwards and fasten to decrease the distance from the LCD screen and the window Figure9 To Lower Loosen the fittings rotate the bracke...

Page 7: ...x2 Reversible bracket x2 Keys x4 Standard parts Double ceiling bracket x 1 Single ceiling bracket x 1 STEP 17 Once the LCD fits correctly remove the display set down in a safe area and then lock the e...

Page 8: ...15 deg enclosure wall Bracket handed x2 Wall bracket x 1 Optional cealing mount brackets LCD Mounting bracket x2 Reversible bracket x2 Keys x4 ndard parts Double ceiling bracket x 1 Single ceiling bra...

Page 9: ...sure brackets and wall plate are securely tightened steadily lift the enclosure onto the wall plate and secure ensuring the brackets are slotted over the wall plates top lip and the enclosure doesn t...

Page 10: ...make sure it s correctly attached to the wall STEP 28 To fully secure the unit to the wall and prevent issues of theft take the locking bar and feed it through the slots on the mounting brackets and p...

Page 11: ...ll use automatic thermostats instead Details on how to use the thermostat are found in the maintenance section Pg14 Kit Needed Armagard USB Cable Armagard USB Drivers Windows 7 Laptop Phillips Screwdr...

Page 12: ...the terminal program mentioned from earlier and locate the setup port which will appear as a COM port Select the correct COM port from the drop down menu as shown in figure 3 box 1 The correct COM po...

Page 13: ...omponents just above the menu shown in box 4 below Figure 4 10 The settings for each component can then be changed by selecting the appropriate option from the menu in box 5 For example to change the...

Page 14: ...ling and 10 C 50 F for heating Simply turn the thermostat dial to the temperature you wish the component to turn on at it the fans are set to 40 C the fans will activate once the internal temperate re...

Page 15: ...ther than those listed or any abrasive cleaners Avoid cleaners of a highly alkaline composition Avoid cleaning in the hot sun or high temperatures SCREEN CLEANING GLASS DISPLAY For high toughed glass...

Page 16: ...46 47 52 55 www Armagard com Installation Manual Page 16 Toll Free US 1 866 434 0807 Call UK 0121 608 7210 For additional support visit www Armagard com or call Free US 1 866 434 0807 Call Free UK 012...

Reviews: