Installation

Installation and wiring must be performed by 
a licensed electrician.

The light must be wired to its own light switch.
Do not interconnect with other lights on the 
same switch.

Step 1.

Wall Mounting

Align mounting plate over desired mounting position
(as shown in Fig. 5) and mark screw holes.

Eave Mounting

For under eave installation, the sensor head must be
rotated to ensure correct operation of the Floodlight
(Refer Fig. 6).

Position the Floodlight under eaves to 
allow sensor to be directed towards the area to be
scanned. Mark mounting holes through mounting
plate.

Do not overtighten or use excessive force when
adjusting sensor head or lampholders.

The sensor head must face as shown 
(see Fig. 6 and 7).

Mounting plate

Joint & clamp screw

Sensor head

Screws & rawl plugs

Locknuts

Weatherproofing
seals

Lampholders

Mounting holes

Horizontal

Eave mount

Wall mount

Fig. 4

Fig. 5

Fig. 6

Fig. 7

Summary of Contents for MAL413

Page 1: ...fully MAL413 To avoid nuisance triggering the sensor should be directed away from heat sources such as barbecues airconditioners other outside lighting flue vents and moving cars Do not aim towards reflective surfaces such as smooth white walls swimming pools etc The scanning specifications 15 metres at 110 scan may vary slightly depending on the mounting height and location Refer Fig 1 and 2 The ...

Page 2: ...he sensor head must be rotated to ensure correct operation of the Floodlight Refer Fig 6 Position the Floodlight under eaves to allow sensor to be directed towards the area to be scanned Mark mounting holes through mounting plate Do not overtighten or use excessive force when adjusting sensor head or lampholders The sensor head must face as shown see Fig 6 and 7 Mounting plate Joint clamp screw Se...

Page 3: ...uld be rotated to adjust the sensor to face the required detection area If necessary loosen sensor arm joint clamp screw C Angle lampholders from mounting surface and direct them approximately downwards away from sensor head D Fit PAR38 globes and weatherproofing rubber seals do not overtighten E Ensure that globes are positioned 40mm or more from the sensor head or mounting surface as shown in Fi...

Page 4: ...ly switch your wall switch OFF If at any time whilst changing operating mode you are unsure which mode the unit is in switch OFF for at least 15 seconds then switch back ON the unit will then be in the Automatic mode NOTE This highly responsive unit may occasionally activate due to rapid environmental changes When first switched on allow approx 90 seconds warm up time for the sensor operation to s...

Page 5: ... does not switch ON when there is movement in the detection area Light switches ON for no apparent reason Poor Sensitivity and range Light remains ON Possible Cause 1 No mains voltage 2 Globe s faulty or missing 3 Wiring incorrect 4 Nearby lighting is too bright 5 Sensor positioned in wrong direction 1 Heat from globe activating sensor 2 Heat sources such as aircon vents heater flues barbecues oth...

Page 6: ...of purchase provided that the product is used in accordance with Arlec s recommendations and within such voltage and current limits as are specified by Arlec in relation to the product Arlec will at its own option make good replace with the same or similar product or provide credit for any product manufactured or supplied by it which proves to be defective within the limits set out above provided ...

Reviews: