© 2019 ARKRAY, Inc.

The following symbols are used in this operating manual to call your 

attention to specific items.

■ For your safety

Follow the instructions given here to prevent exposure to 

pathogenic microorganisms.

Follow the instructions given here to prevent injury and property 

damage.

■ For optimal performance

IMPORTANT:

Follow the instructions given here to obtain accurate measurement 

results.

NOTE:

Information useful for preventing damage to the instrument or parts, 

and other important information you should keep in mind.

REFERENCE:

Additional explanations that help you make the best use of the instrument 

and information on related functions.

Thank you for purchasing our compact biochemical analyzer, The Lab 

004.

This operating manual contains important information on the functions of 

The Lab 004.

This operating manual is issued by ARKRAY, Inc.

Read carefully prior to starting up the unit.

It is recommended to retain this operating manual for future use.

The Lab 004 (DB-3910) instrument is intended for the quantitative and 

automated measurement of several physiological markers in serum and 

plasma. This instrument is intended for use with The Lab 004 reagent 

strips. For information about the analyte, the function and the target 

disease/condition as well as the intended use population, please refer to 

the reagent instructions for use. For 

in vitro

 diagnostic use and 

professional use only.

This product conforms to the EMC Standard IEC61326-2-6:2012 

(EN61326-2-6:2013).

Class of emission: CISPR 11 Class A

This instrument is an IVD medical instrument.

This product conforms to Regulation (EU) 2017/746.

This instrument generates, uses and can radiate radio frequency energy 

and, if not installed and used in accordance with the operating manual, 

may cause harmful interference to radio communications. Operation of 

this instrument in a residential area is likely to cause harmful 

interference in which case the user will be required to correct the 

interference at his own expense.

The electromagnetic environment should be evaluated prior to operation 

of the device. Do not use this device in close proximity to sources of 

strong electromagnetic radiation, as these may interfere with proper 

operation.

Premise

Symbols

Read this operating manual thoroughly before using the instrument. This 

operating manual gives an overview of the instrument and the proper 

procedures for operation and maintenance. Follow the instructions in 

this operating manual in order not to defeat the purpose of the protective 

features of the instrument.

If you have had or could have had any serious incident related to the 

device, please report it directly to the manufacturer or through the 

authorised representative and to your local regulatory authority.

For the purchase of reagents, consumables or other optional items, 

contact your distributor.

Introduction

• TAKE THE UTMOST CARE WHEN HANDLING BLOOD. This 

instrument uses blood as sample. Blood may be contaminated 

with pathogenic microorganisms that can cause infectious 

diseases. Improper handling of blood may cause infection to 

the user or other individuals by pathogenic microorganisms.

• This product is intended for professional use only and hence 

the system is to be operated by qualified persons only. A 

qualified person is one having adequate knowledge of clinical 

testing and the disposal of infectious waste. Thoroughly read 

this operating manual before use.

• Never touch the strip tray or other parts where the sample may 

adhere with your bare hands. During cleaning or maintenance 

of these parts, wear disposable gloves to prevent exposure to 

pathogenic microorganisms.

• Dispose of used samples, tips, reagent strips, parts and 

instrument in accordance with local regulations for 

biohazardous waste. 

For a description of the performance characteristics, reference 

intervals, warnings and limitations specific to the reagent, refer 

to the reagent product insert.

NOTE:

This product is a precision instrument. Handle the instrument with care. 

Do not subject the instrument to strong impact or vibration

• It is strictly prohibited to copy any part of this operating manual without the 

expressed consent of ARKRAY, Inc.

• The information in this operating manual is subject to change without notice.

• ARKRAY, Inc. has made every effort to prepare this operating manual. 

Should you discover anything strange, incorrect or missing, please contact 

your distributor.

84-08673

Summary of Contents for Lab 004

Page 1: ...in close proximity to sources of strong electromagnetic radiation as these may interfere with proper operation Premise Symbols Read this operating manual thoroughly before using the instrument This operating manual gives an overview of the instrument and the proper procedures for operation and maintenance Follow the instructions in this operating manual in order not to defeat the purpose of the pr...

Page 2: ...d in package insert of reagent Measurement principle Listed in package insert of reagent Dual wavelength transmitted light measurement Number of reagent strips measurable at once 1 Measurement time Listed in package insert of reagent Approximately 4 μL Sample consumption Listed in package insert of reagent 1 sample Approximately 10 minutes in environments 25 C and below Memory capacity 50 measurem...

Page 3: ...adapter Use a battery with a rating of 5 V and 2 0 2 4 A Do not disassemble the instrument Do not modify the instrument Disassembly and modification of the instrument may result in exposure to pathogenic microorganisms or cause fire or damage to the instrument and consequently lead to personal injury 1 4 2 Precautions for Instrument Relocation Before relocating the instrument read the following no...

Page 4: ... infectious diseases Improper handling of blood may cause infection to the user or other individuals by pathogenic microorganisms Dispose of used samples in accordance with local regulations for biohazardous waste When using a sample that has been stored in a refrigerator or freezer allow the sample to acclimate to the ambient temperature 10 35 C prior to measurement Do not store a sample in direc...

Page 5: ... from a New Box Wear disposable gloves to prevent exposure to pathogenic microorganisms If sample adheres to the instrument wipe it off with a cotton swab or gauze dampened with distilled water Make sure that no dirt is left and then ensure that the surface is disinfected with alcohol Leaving the instrument with the sample adhered to it may cause infection to the user or other individuals by patho...

Page 6: ...d time are set a On the standby screen press and hold for 3 seconds to display the MENU screen 1 0 0 will appear in the sub screen with the 1 digit blinking b Press the button The 1 will stop blinking and the middle 0 digit will change to 1 and start blinking c Press the button once The middle digit will change to 2 d Press the button The MENU No will be finalized as 1 2 and the screen will transi...

Page 7: ...red Use a new reagent strip and repeat measurement E 124 The tray was withdrawn during measurement Press the button to clear the error and repeat measurement E 126 The measurement count limit of the inserted IC CHIP has been exceeded Insert the IC CHIP inside of the box of the reagent strip to be measured into the port on the back of the instrument and repeat measure ment E 128 Unable to read the ...

Page 8: ...omatic dry biochemical analyzer RATING MADE IN PHILIPPINES Environment During Transport Semi Auto matic dry biochemical analyzer RATING MADE IN PHILIPPINES Storage Environment Storage Environment Environment During Transport This product conforms to Regulation EU 2017 746 In vitro diagnostic medical device Manufacturer Date of manufacture Authorised Representative in the European Community Importe...

Reviews: