5 INSTALLATION
5.1. The fluid direction makes no difference when the meter is installed. It must be
assembled in the delivery, after the pump.
5.2. The meter is assembled in such a way that the digit reading and its keys are lined up
with the tube inlet/outlet holes.
When turning 90º the frontal cover to make easier its reading and key handling, unscrew
the 4 screws (1) with an Allen screwdriver and put the cover in the desired position.
Before closing the cover, check that the joint (8) is well-positioned and screw again the
screws (1) in its holes.
5.3. It is necessary to use sealing components on the installation pipes and threads,
which are resistant to the products to be transferred.
5.4. ATTENTION:
Use sealing elements with care. Please take care no remains go into the
measuring chamber. This can cause a meter breakdown.