2 TECHNICAL SPECIFICATIONS
The meter has an aluminium measuring chamber and 2 high accuracy oval gears.
It is suitable for the transfer of mineral oil, diesel, heating oil, motor oil up to SAE-140
(please, ask for other liquids).
It is inserted into the fuel and oil distribution line and its operation is private. The
calibration parameters and the litre totalizer are saved in a PERMANENT memory.
The MAGF1 model has two keys and a big LCD-Display in order to make easier its
display.
Flow
5-110 l/min (diesel)
5-80 l/min (lubricant)
Channels
2
Phase-out channel
180º
Pulses per channel
20.5 pulses x litre and channel
Max. pressure loss
0.3 bar (diesel)
Max. pressure
55 bar
Temperature
- 10 / +50 ºC
Max. humidity
95 H.R.
Viscosity
2-2000 cSt
Accuracy
0.5%
Noise
LEQA < 70 dBA
Repetitivity
0.2%
Inlet-outlet connections
1" BSP flange
Battery life
4 years (approx.)
Dimensions (mm)
123 x 68 x 123
Net Weight (kg)
0.850
Packaging dimensions
147 x 85 x 140
Gross Weight (kg)
0.900