10. Accessories

GARMENTS AND TUBING

Description

Garment 
Part No.

Size

Standard Calf Garment

DVT10

Circumference

up to 43cm (17”)

Calf Garment (Sterile)

DVT10S

Circumference

up to 43cm (17”)

Large Calf Garment

DVT20

Circumference

up to 58cm (23”)

Standard Thigh Garment

DVT30

Circumference

up to 71cm (28”)

Thigh Garment (Sterile)

DVT30S

Circumference

up to 71cm (28”)

Large Thigh Garment

DVT40

Circumference

up to 89cm (35”)

Extra Large Calf Garment

DVT60L

Circumference

up to 81cm (32”)

Calf Garment

L501-M

Circumference

up to 43cm (17”)

Thigh Garment

L503-M

Circumference

up to 71cm (28”)

Connector Tubing

L550 

(SP057)

Length

150cm (60”)

Connector Tubing

L552 

(SP061)

Length

300cm (118”)

Summary of Contents for Flowtron Excel

Page 1: ...Flowtron Excel Instructions for Use with people in mind 247933EN_0 201 ...

Page 2: ......

Page 3: ...e Pump 5 Garment Application 5 Garment Removal 5 To Use Only One Garment 5 Pre Use Check 6 Operation 7 Start Up 7 Shut Down 7 Pressure Adjustment 8 Pressure Output Check 8 Adjusting the Output Pressure 8 System Calibration Check 8 Decontamination 9 Routine Maintenance 10 Flowtron Excel System 10 Flowtron Excel Pump 10 Serial Labels 10 Troubleshooting 11 Alarm Cancel 11 Accessories 12 Garments and ...

Page 4: ... ii ...

Page 5: ...ket Disconnect the pump from the mains power socket before cleaning and inspecting Keep the pump away from sources of liquids and do not immerse in water Do not use the pump in the presence of uncontained flammable liquids or gases Only the pump and garment insert combination as indicated by ArjoHuntleigh should be used The correct function of the product cannot be guaranteed if incorrect pump and...

Page 6: ...n expected service life of seven years To maintain the condition of the pump have the pump serviced regularly according to the schedule recommended by ArjoHuntleigh Do NOT use unapproved accessories or attempt to modify disassemble or otherwise misuse the Flowtron Excel system Failure to observe this caution could result in injury or in extreme cases death Environmental Protection Incorrect dispos...

Page 7: ...home healthcare environment The Flowtron Excel system should be used as part of a prescribed plan of care refer to Indications on page 3 About Flowtron Excel The Flowtron Excel pump operates on a 60 second automatically timed cycle consisting of approximately 12 seconds of inflation followed by approximately 48 seconds of deflation The Flowtron Excel system may be used on patients at risk of devel...

Page 8: ...2 Flowtron Excel Pump Front View Mains Power Switch Carry Handle Pressure Display Garment Pressure Control Connectors Single Leg Mode Button and Indicator ...

Page 9: ...o the heart may be detrimental 4 Pulmonary embolism 5 Any local condition in which the garments would interfere including gangrene recent skin graft dermatitis or untreated infected leg wounds If you are unsure of any contraindications refer to the patient s physician before using the device Cautions 1 Proper garment application and connection to the pump is essential 2 Garments should be position...

Page 10: ...cian the clinician should ensure that the compression stockings are properly measured applied and worn by the patient Any compression stocking used should be routinely checked to ensure continued proper fit and application in addition to assessing the condition of the skin Where appropriate patients should be instructed in the proper use of the system the purpose of therapy and that any problems s...

Page 11: ...ment against the leg wrap the tabs over the top Ensure that the garment is close fitting and has no creases or folds The connector tubing should be pointing towards the patient s heel 5 Make sure the tubing assembly is connected to the garment connector on the pump 6 Connect the garment connector to the tubing assembly Ensure that a sharp click is heard Pull lightly to confirm proper connection 7 ...

Page 12: ...Garments have been applied to the patient s legs correctly close fitting and without creases or folds There are no kinks in the tubing The pump is connected to the mains power supply but not switched on All tubing connections are secure The system has been arranged so that the power cable and garment tubing do not pose a trip or strangulation hazard ...

Page 13: ...illuminates If the Single Leg button is pressed while two garments are connected the system will automatically reset to two garment operation after two single garment inflation cycles Verify that the pressure display is indicating the desired output pressure prescribed by the physician Refer to section Pressure Adjustment on page 8 for specific pressure setting instructions If the operation or per...

Page 14: ...mance The pressure display is used for the following functions Pressure Output Check After turning the pump on check that the pressure display is showing the desired output pressure when the garments are inflated Visually recheck the display at regular intervals Adjusting the Output Pressure If necessary the pressure can be adjusted during the active inflation period by rotating the pressure contr...

Page 15: ...m 250ppm to 10 000ppm depending on local policy and contamination status Wipe all cleaned surfaces with the solution then wipe using a cloth moistened with water and dry thoroughly Alcohol based disinfectants strength 70 may be used as an alternative Ensure the product is dry before storage If an alternative disinfectant is selected from the wide variety available we recommend that suitability for...

Page 16: ...Flowtron Excel pump is serviced every 12 months by an ArjoHuntleigh authorised service agent Flowtron Excel Pump General Care Maintenance and Inspection Check all electrical connections and power cable for signs of excessive wear Check the tubeset and connectors for any damage In the event of the pump being subjected to abnormal treatment e g immersed in water or dropped the unit must be returned ...

Page 17: ...t has been cleared If the troubleshooting procedures do not return the system to normal performance stop using the system immediately and call the service engineer Display Problem Corrective Action 1 Hose disconnected at garment 2 Garment leak 3 Low pressure 1 Check the hose connection at garment end 2 Check garment and replace if faulty 3 Call the service engineer 1 Hose kinked causing a blocked ...

Page 18: ... to 58cm 23 Standard Thigh Garment DVT30 Circumference up to 71cm 28 Thigh Garment Sterile DVT30S Circumference up to 71cm 28 Large Thigh Garment DVT40 Circumference up to 89cm 35 Extra Large Calf Garment DVT60L Circumference up to 81cm 32 Calf Garment L501 M Circumference up to 43cm 17 Thigh Garment L503 M Circumference up to 71cm 28 Connector Tubing L550 SP057 Length 150cm 60 Connector Tubing L5...

Page 19: ...against electric shock Class II Double Insulated with Functional Earth Type BF Degree of protection against liquid ingress IPX0 No protection Mode of operation Continuous Cycle or Therapy Modes 60 seconds total 12 seconds inflation 48 seconds deflation Pressure Range 30 60 mmHg 4 mmHg ENVIRONMENTAL INFORMATION Condition Temperature Range Relative Humidity Atmospheric Pressure Operating 10 C to 40 ...

Page 20: ...by the name and the address of the manufacturer Guidance and manufacturer s declaration electromagnetic emissions The pump is intended for use in the electromagnetic environment specified below The customer or the user of the pump should assure that it is used in such an environment Emissions Test Compliance Electromagnetic environment guidance RF emissions CISPR 11 Group 1 The pump uses RF energy...

Page 21: ... determined by an electromagnetic site survey a should be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment marked with the following symbol Note At 80 MHz and 800 MHz the separation distance for the higher frequency range applies Note These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption an...

Page 22: ...tance according to frequency of transmitter m 150 kHz to 80 MHz d 1 2 P 80 MHz to 800 MHz d 1 2 P 800 MHz to 2 5 GHz d 2 3 P 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 2 8 3 8 7 3 100 12 12 23 For transmitters rated at a maximum output power not listed above the recommended separation distance d in metres m can be estimated using the equation applicable to the frequency of the transmi...

Page 23: ...uality should be that of a typical domestic commercial or hospital environment Mains power quality should be that of a typical domestic commercial or hospital environment Surge IEC 61000 4 5 1 kV line s to line s 2 kV line s to earth Complies Voltage dips short interruptions and voltage variations on power supply input lines IEC 61000 4 11 5 UT 95 dip in UT for 0 5 cycle 40 UT 60 dip in UT for 5 c...

Page 24: ...18 ...

Page 25: ...19 ...

Page 26: ...20 ...

Page 27: ...mplex Dubai Biotechnology Research Park P O Box 214742 Dubai United Arab Emirates Tel 971 0 4 447 0942 E mail Info ME getinge com NEDERLAND ArjoHuntleigh Nederland BV Biezenwei 21 4004 MB TIEL Postbus 6116 4000 HC TIEL Tel 31 0 344 64 08 00 Fax 31 0 344 64 08 85 E mail info nl arjohuntleigh com NEW ZEALAND ArjoHuntleigh Ltd 41 Vestey Drive Mount Wellington NZ AUCKLAND 1060 Tel 64 0 9 573 5344 Free...

Page 28: ...es solutions for infection FRQWURO ZLWKLQ KHDOWKFDUH DQG FRQWDPLQDWLRQ SUHYHQWLRQ ZLWKLQ OLIH VFLHQFHV Maquet specializes in solutions therapies and products for surgical interventions interventional cardiology and LQWHQVLYH FDUH ArjoHuntleigh focuses on patient handling and hygiene disinfection DVT prevention medical EHGV WKHUDSHXWLF VXUIDFHV DQG GLDJQRVWLFV ArjoHuntleigh AB Hans Michelsensgatan ...