background image

Safety Instructions

7

001.1

1720.EN rev

. 13

General Instructions

Important Safety Instructions

Always ensure that:
• The unit is used by trained staff.
• All controls and safety features are used only

according to the rules specified in this manual.

Never attempt to force a control or button on

the KWIKtrak Turntable.

• Any  precautionary  or  instruction  labels  are

read and those that cannot be easily read are

replaced.

• The  daily  maintenance  is  carried  out  before

using the unit.

Safe Working Load (SWL)

Shock Prevention

Do not splash or expose the device to water or 

moisture.
Do not attempt to expose, service or repair the 

KWIKtrak Turntable. 
If the unit is defective, contact your local Arjo 

agent.

Environmental Advice

When disposing of any items associated with the 

product, contact the appropriate local authorities 

for information. 

Homecare Environmental Considerations

WARNING: All track ends must have an end

stopper in place and secured. They are part

of  safety  features.  A  missing  end  stopper

might lead to a patient fall.

WARNING: There must be an end stopper in

each red zone labelled “NO RAIL”. They are

part  of  safety  features.    A  missing  end

stopper might lead to a patient fall.

CAUTION:  Keep  all  components  of  the

turntable clean and dry.

NOTE: The Automatic KWIKtrak Turntable is

designed to be used with ceiling lift series

#910XXXX, 

#911XXXX, 

#913XXXX,

#923XXXX,  #LDXXXX  and  MSX1X-XX-XX

only. 

NOTE:  The  Manual  KWIKtrak  Turntable  is

designed to be used with portable ceiling lift

and  ceiling  lifts  listed  above  (see  the

previous note box regarding the Automatic

KWIKtrak Turntable).

WARNING:  Arjo  warns  of  possible

strangulation risks related to the pull cords

and advises to take necessary precautions

to prevent these.

WARNING:  The  KWIKtrak  Turntable  is

intended to be used with ceiling lifts which

the SWL does not exceed 272 kg (600 lb). Do

not attempt to use the unit with  more than

the  lowest  weight  limit  indicated  on  the

following:
• the track system;

• the turntable unit

• the “maximum load” label on the lift;

• the sling.
Overloading any of these elements may lead

to a patient fall and to injuries.

WARNING:  This  product  contains  small

parts  that  might  present  a  choking  hazard

for children if swallowed or inhaled.

WARNING:  The  KWIKtrak  Turntable  is  not

intended to be operated by children. Serious

injuries could occur.

NOTE: Rigorous cleaning actions should be

done  when  the  turntable  is  exposed  to  an

animal.  Pet  hair  trapped  inside  the  device

can reduce the product performance.

Safety Instructions

Summary of Contents for KWIKtrack

Page 1: ...INSTRUCTIONS FOR USE KWIKtrack Turntable 001 11720 EN rev 13 09 2019...

Page 2: ...ing to the Arjo group of companies Arjo 2019 As our policy is one of continuous improvement we reserve the right to modify designs without prior notice The content of this publication may not be copie...

Page 3: ...onmental Advice 7 Homecare Environmental Considerations 7 Product Description Labels 8 Automatic KWIKtrak Turntable 8 Manual KWIKtrak Turntable 9 How to Use the KWIKtrak Turntable 10 Automatic KWIKtra...

Page 4: ...notice any changes in the performance of your turntable or if you need any help in setting up using or maintaining your KWIKtrak Turntable The agent can offer support and service programs to maximize...

Page 5: ...on to the initial track path Product Identification The unit s identification numbers specification model serial number appear on a silver name plate fixed inside the track of the KWIKtrak Turntable H...

Page 6: ...and recycle according to the European Directive WEEE or local regulation It refers to the Instructions for Use It points out the turntable is on automatic rotation mode It points out the turntable is...

Page 7: ...pper might lead to a patient fall CAUTION Keep all components of the turntable clean and dry NOTE The Automatic KWIKtrak Turntable is designed to be used with ceiling lift series 910XXXX 911XXXX 913XX...

Page 8: ...720 EN rev 13 Automatic KWIKtrak Turntable Fig 2 1 2 3 5 4 6 Manual rotation Powered rotation Product Description Labels Legend 1 Automatic KWIKtrak Turntable 2 Quick release 3 Covers 4 Pivoting track...

Page 9: ...oduct Description Labels 001 11720 EN rev 13 Manual KWIKtrak Turntable Fig 3 1 2 3 5 4 6 Legend 1 Manual KWIKtrak Turntable 2 Activation arm 3 Activation pull cord 4 Pivoting track 5 Covers 6 End stop...

Page 10: ...the pivoting track is aligned with the next position 3 Move the lift out of the turntable along the new path 4 In case of a malfunction pull down the activation arm to unlock the pivoting track and ro...

Page 11: ...dures by Arjo and equipped with correct tools and proper documents including Parts List and Service Manual Failure to meet these requirements could result in personal injuries and or unsafe equipment...

Page 12: ...s intended after checking the previous point immediately contact your Arjo agent The turntable stops moving between track and beeps The turntable is in over current condition Verify if an object is re...

Page 13: ...er Requirements automatic model 24 VDC 1 A Designed to be powered by the lift IP rating 700 11600 IPx2 OPERATION AND STORAGE CONDITIONS Ambient temperature range Operation 5 C to 40 C 41 F to 104 F St...

Page 14: ...14 Technical Specifications 001 11720 EN rev 13 KWIKtrak Turntable Dimensions Fig 6...

Page 15: ...it could result in improper operation If such use is necessary this equipment and the other equipment should be observed to verify that they are operating normally WARNING The equipment may cause rad...

Page 16: ...rst IEC 61000 4 4 Not applicable Not applicable Mains power quality should be that of a typical commercial or hospital environment Surge IEC 61000 4 5 Not applicable Not applicable Mains power quality...

Page 17: ...n 0 15 80 MHz N A Radiated RF IEC 61000 4 3 10 V m 80 MHz to 2 7 GHz 10 V m 80 MHz to 2 7 GHz N A Proximity fields from RF wireless communications equipment IEC 61000 4 3 380 390 MHz 27 V m PM 50 18 H...

Page 18: ...Page intentionally left blank...

Page 19: ...9 0 6 87426222 E mail Italy promo arjo com MIDDLE EAST Arjo Middle East FZ LLC Of ce 908 9th Floor HQ Building North Tower Dubai Science Park Al Barsha South P O Box 11488 Dubai United Arab Emirates D...

Page 20: ...e ergonomic patient handling personal hygiene disinfection diagnostics and the effective prevention of pressure ulcers and venous thromboembolism we help professionals across care environments to cont...

Reviews: