background image

 PELLET STOKER KMP PX22

6G>I:GBHL:9:C67

 

  

Installation Instructions - 

2010.06.22 - 13/16

  Assemble description

1 Slacken off the screws holding the inner pipe.

2 Chose a suitable position for the feeder tube and fix it by means of the attached 

screws.  
CAUTION: the lower edge of the pipe must enter the inlet hole of the inner tube.

3 Place the cut out-thermostat in the open stainless steel box, fasten the box to the  

feeder tube with the two screws, the metal side of the thermostat facing towards  
the tube.

4 Undo the two screws on the bottom side of the burner. Push them forward in the  

slots until the ignition element touches the inner tube. Tighten the screws.  
The burner is now ready for installation.

Summary of Contents for px22

Page 1: ...9 G 8I DCH DG CHI6AA6I DC 6C9 JH PX22 ...

Page 2: ...ing Turn it to scroll through the menu or change the value when adjusting Pushing once makes a selection or saves in the menu Example Power the burner Pressing once causes the panel to ask Start Pressing again means that you confirm the question and the burner starts If you turn one increment clockwise instead you jump in the main menu and come to Start T Turn further to access the respective Stop ...

Page 3: ...s during startup especially if the stoker is not properly adjusted Screw feeder Allways observe the following UÊ The feeder inlet opening is not to be less than 100 mm from the bottom 150 mm from the nearest side wall of the storage bin UÊÊ The feeder has to be inclined between 40 and 50 from horizontal UÊÊ Attach the feeder thoughly to keep it from working its way into the storage bin UÊÊ The ext...

Page 4: ...m the top of the chimney If temperature exceeds 60 C there is little risk of condensation If lower temperature measures have to be taken Also look for signs of dampness in the lower parts of the chimney If so the flue gas temperature has to be rizen If there is only a small amount of moisture in the upper part installation of a draught pass might be sufficient Alternatively the stoker can be run onl...

Page 5: ...d cables and connectors NOTE The stoker has to be connected to the mains on a manual reset cut out ther mostat on the boiler This must be carried out by an authorised engineer The bulb of the cut out thermostat has to be immersed in the boiler water or other wise located on the boiler where a quick action is guaranteed in case of overheating If there is no thermostat on the boiler an external one ...

Page 6: ...ow output mode LO Power Adjust Feed LO in the Settings menu until combustion is approved Do not forget to activate the desired output mode again 5 If the output is to be adjusted first change the combustion air Air HI and Air LO then the fuel amount by repeating steps 3 and 4 Pellets quality The burner can handle most types of clean wood pellets however 6 or 8 mm pellets are recommended The quality...

Page 7: ...sation may lead to corrosion of the boiler body If the calorifier and shunt valve is situated in in the tank the temperature sensor can alternatively be placed on the tank this leading to longer running intervals thus minimizing the number of starts and stops Placing the temperature sensor on the tank If the temperature sensor is to placed on the storage tank the charging pump system must have capa...

Page 8: ...ts In this case the display shows in which operating mode the flame stopped being indicated and stops as follows ErrStart Operational stoppage at ignition ErrLow Operational stoppage in low output mode ErrHigh Operational stoppage in high output mode GOutStrt Flame indicated at ignition but not in operation Resetting cut out thermostat The burner has overheat protection on the fall pipe which deplo...

Page 9: ...w that holds the element and pull out the element from its pipe 6 Replace the element 7 Refit in reverse order 8 Ensure that the firing element is slid forward towards the inner pipe Changing light sensor 1 Disconnect all three cables on the stoker 2 Remove the burner cover by removing the two nuts and screws and pull the cover back 3 Disconnect the edge connector from the control circuit board and ...

Page 10: ... mode Check the pellet supply and the Feed HI and Air Su settings The burner stops Fault code GOutStrt UÊÊ iÊLÕÀ iÀÊ ÌÊLÕÌÊÌ i ÊÜi ÌÊ out during pre operation Check the pellet supply and the Feed SU and Air Su settings ServCode The burner stops Fault code ErrorIgn UÊÊ iÊwÀ Êi i i ÌÊ ÃÊ ÌÊ drawing any power Check the connections to the firing element 120 145 Ohm or replace the firing element The burn...

Page 11: ...6 7 4 11 12 13 14 15 16 10 17 18 19 20 22 35 24 25 26 27 29 15 30 31 32 34 37 28 33 23 21 9 8 36 29 PELLET STOKER KMP PX22 6G I GB HL 9 C 67 Installation Instructions 2010 06 22 11 16 Exploded view Technical data ...

Page 12: ...arriage plate PX21 4 8117 Screw MLC6S M6 x 16 untr 5 8148 Nut M6M M6 FZB 6 2585 Gasket rope 10 mm black coated 7 1150 Docking flange PX2X 8 8231 Dome nut M6 FZB 9 3120 Insulation 10 1493 Connector plate PX22 11 1151 Plate for docking flange PX2X 12 1451 Flame detector for burner Cc05 13 8133S crew MLC6S M6 x 10 untr 14 1288 Fall pipe with flange PX2X 15 1566 Spacer screw Steel M4x5 Px22 16 1490 Elect...

Page 13: ...AUTION the lower edge of the pipe must enter the inlet hole of the inner tube 3 Place the cut out thermostat in the open stainless steel box fasten the box to the feeder tube with the two screws the metal side of the thermostat facing towards the tube 4 Undo the two screws on the bottom side of the burner Push them forward in the slots until the ignition element touches the inner tube Tighten the ...

Page 14: ...PELLET STOKER KMP PX22 6G I GB HL 9 C 67 Installation Instructions 2010 06 22 14 16 Warranty For warranty issues Ariterm Sweden AB refers to our local Distributor ...

Page 15: ...PELLET STOKER KMP PX22 6G I GB HL 9 C 67 Installation Instructions 2010 06 22 15 16 Declaration of conformity ...

Page 16: ... are not followed during installation operation and maintenance the obligations of Ariterm Sweden AB under the warranty regulations are no longer binding Ariterm reserve the right to alter any details and specifications without prior notice Ariterm Sweden AB Flottiljvägen 15 SE 392 41 Kalmar www ariterm se ...

Reviews: