background image

ARITERM SWED

EN

 A

|

 Flot

tiljvägen 15 

39241 Kalmar 

|

 www.arit

erm.

se 

0771-442850

Summary of Contents for Biomatic 50

Page 1: ...INSTALLATION OPERATION AND MAINTENANCE Biomatic 50 ...

Page 2: ...tion this must always be communicated to the local building authorities Sweeping According to the fire protection laws a chimney shall be swept regularly This is done by the local chimneysweep Sweeping of the boiler shall be carried out in such a man ner that good operating economy is achieved see under Maintenance Prepare to chimney sweeping by turning off the boiler at least one hour before cleani...

Page 3: ...tt gäller exkl ställbara fötter 725 410 600 245 606 1690 264 410 500 425 1229 270 240 Ø 139 utv 389 758 728 304 162 A 1560 150 154 Kombinationsrökrör 620 130 Ø159 Ø159 50 TECHNICAL SPECIFICATION Performance Capacity range pellets 25 50 kW Dimensions Width Depth without flue pipe Height without connections Weight Water contents 606 mm 720 mm 1690 mm 452 kg 115 l Design values and settings Design pr...

Page 4: ...te maintenance work Sweeping is mainly done from the soot hatch on top of the boiler but also through the rebox door where the burner is located The boiler is designed to operate with a pellet burner Biomatic 50 consists of a combustion chamber with flue pipes which is enclosed by a jacket holding 115 litres of water Heat generated by the burner is transferred directly to the boiler water Oil heati...

Page 5: ...ircuit S20 Switch external circ pump heating circuit On Off S21 Switch internal circ pump hot water circuit continous operation TS Regulating thermostat burner TZ High limit thermostat burner THERMOSTAT CONNECTION MAINS SUPPLY MMJ 3x1 5 mm2 MAINS SUPPLY PELLER BURNER CONN EXTERNAL CIRC PUMP HEATING CIRCUIT CONN FLOW SWITCH EXTERNAL CIRC PUMP HOT WATER CIRCUIT CONN EXTERNAL CIRC PUMP HOT WATER CIRC...

Page 6: ...mended underpressure in the chimney is 25 Pa The height of the gas flue shall be dimensioned according to the building s requirements but should be at least 6 m If condensation water comes out of the flue a condensate drain pan shall be installed in the lower portion of the chimney The combustion air intake must not be covered 1 Regulating thermostat Adjustment of operating temperature for pellet bu...

Page 7: ...anufacturer s instructions In the following table you will find examples of suitable closed system expansion vessels System volume Opening pressure Initial pressure Vessel volume litre bar bar litre 70 C 90 C 500 1 5 0 5 35 80 1000 1 5 0 5 80 140 1500 1 5 0 5 80 140 2000 1 5 0 5 140 200 An open system with 500 litre water volume demands at least a 35 litre expansion vessel and a 1500 litre system v...

Page 8: ...the same value as the big needle FILLING OF WATER MAINTENANCE CARE SWEEPING Boiler cleaning Burning solid fuels even if operation is automated normally calls for a little more care and maintenance than oil heating For Biomatic 20 maintenance has been minimized as the result of well planned design and a big ash box holding 50 litres Ash is removed when necessary The convection parts of the boiler a...

Page 9: ...at you get clean and dry pellets and no fines ATTENTION Damp pellets must be rejected immediately FUEL RECOMMENDATION Raw material Chemically untreated barkless wood Diameter 8 mm Length 15 to 32 mm Volume weight over 600 kg m3 Moisture content less than 10 Ash content less than 0 7 weight Fine material content max 4 weight Melting temperature of ash 1100 C Energy content 4 75 kWh kg PELLET STORE T...

Page 10: ...ture or over pressure Any attempts made to repair the product without the manufacturer s permission or if the guarantee card has not been returned to the manufacturer will invalidate the guarantee The manufactu rer shall not be held liable for any possible indirect damage and or financial loss caus ed by the burner Ariterm AB reserves the right to decide the method how a possible guarantee repair i...

Page 11: ...emperature boiling risk If these instructions are not followed during installation operation and maintenance the obligations of Ariterm AB under the warranty regulations are no longer binding Ariterm reserves the right to alter any details and specifications without prior notice Flue gas temp High CO Retailer Installer Installed by Inst date O2 CO2 Efficiency Draught mm Fan Effect Flue gas temp Low...

Page 12: ...ARITERM SWEDEN AB Flottiljvägen 15 39241 Kalmar www ariterm se 0771 442850 ...

Reviews: