Cleaning of Flame Control
The condition of the burner head
wheels must be checked during
maintenance.
The burner cup and the
screws within the cup must
be carefully cleaned to ensure
flawless operation.
Pull the flame control sensor gently out of the
pipe.
Clean the flame control sensor.
Clean the flame controller metal pipe so
that the ash in the pipe will not hinder the
operation of the flame control sensor.
MAINTENANCE, CARE, SWEEPING
Check the condition of the chain and wheels regularly.
Change worn out parts when necessary
.