3.4 Report options

3.4.1 Destination telephone number for reporting
Each event can be reported to any combination of the six central station telephone numbers. If no tel-
ephone number is programmed for a certain event, the event is not reported.

3.5 Protocol options
There are a number of parameters that may be set for each central station protocol, these settings are
configured in this menu.

3.5.1 SIA 1

This menu enables you to set the SIA options.

One Acknowledge per message
You will need to enter YES or NO at this option, depending on the way in which the PAC handles alarm
messages.

SIA message reporting protocol

Programme option to

Account code  ... Ack... BA01/BA02/BA03...Ack...NUL...Ack

No

Account code ... Ack...BA01...Ack...BA02...Ack...NUL...Ack

Yes

3.5.2 Fast Format
The dialler can report to 8 or 16 channel fast format receivers. The dialler automatically switches to 16 if an
event is assigned to one of the 9 to 16 channels.

Channel options
This is the part of the program where you select the channels on which the different events should be
reported. For example, if you want an activation of a burglar alarm only to be reported via channel 3, scroll

down to BA, Enter  

.

 and select channel 3. To select channel 3 move the cursor to the desired position and

press 

0

 to toggle the channel number on or off display.

Options

The same type of event can be reported on more than one channel.

All channels report their status simultaneously.

The first alarm event for this channel starts a transmission. Restore is forwarded when all the events
associated with this channel are restored.

Handshake
The handshake frequency can be set to 1400 Hz or 1600 Hz.

Summary of Contents for TD8403

Page 1: ... 1 TD8403 TD8803 TD8412 TD8812 DIALLER PROGRAMMING MANUAL LK8803 LK8812 ...

Page 2: ... 2 ...

Page 3: ...en written with great care However Aritech cannot be held responsible for any errors occurring in this publication or for their consequences Aritech products are warranted in accordance with the terms of the applicable Aritech product specification Product performance can be affected by system configuration the application customer data and operator control of the system among other factors While ...

Page 4: ...3 1 3 Central station 1 attempts 12 3 1 4 PABX no 12 3 1 5 Previous menu 12 3 2 Dialling options 12 3 2 1 Pulse Tone dialling 12 3 2 2 Wait for dialling tone Yes No 12 3 2 3 Call interval ss 12 3 2 4 Retry period mm 12 3 2 5 No of attempt nn 13 3 2 6 FTC nn 13 3 3 Inputs 13 3 3 1 Selecting SIA events for the inputs 13 3 3 2 Restore restore message 14 3 3 3 Trigger NO NC 14 3 3 4 Delayed events 14 ...

Page 5: ...ine Monitor ON OFF 21 3 9 2 Telephone line options 21 3 9 3 Answ Tel in alarm 21 3 9 4 Leave dialler 21 4 USER menu 19 4 1 Follow me number 22 4 2 Service telephone number 22 4 3 Start dialling 22 4 4 User code 22 5 APPENDIX A Programming Map 23 6 APPENDIX B Programming Map with default settings 27 6 1TELEPHONE ACCOUNT NUMBERS 27 6 2 DIALLING OPTIONS 27 6 3 INPUTS SIA 27 6 4 REPORTING OPTIONS 28 6...

Page 6: ... 6 ...

Page 7: ...ers receive alarm messages from the control panel in SIA format For example BA01 for an burglar alarm in zone 1 or FA02 for a fire alarm in zone 2 The programming of the TD is therefore based on these events SIA events are assigned to a channel in fast format and to a telephone number 1 2 How to use this manual This manual describes how the dialler should be installed and programmed Read through t...

Page 8: ...mmon message may for example be the name and address of the premises where the alarm has been activated Total recording time approx 40 seconds Input for telephone RJ11 connector to record the spoken alarm messages Input for listen in microphone TD8803 TD8812 only Order Product Code RD5045 1 7 2 RC815 Relay card TD8803 TD8812 only Features Two relays with single pole double throw contact Screwed on...

Page 9: ...option 2 INSTALLATION 2 1 How to install Completely disconnect the control panel from all power before installing dialler 2 1 1 Aritech CS350 control panel Place the TD dialler behind the circuit board of the CS350 with the terminals in line with the terminals of the CS350 PCB Connect the dialler to the telephone line taking any local or regional regulations into account Connect the dialler to the...

Page 10: ...ork Microphone Input RD3000AGC KEYPAD 1 CD3008 KEYPAD 2 4 CD3008 12V dc DIP switch Keypad1 ON OFF 8 7 6 5 4 3 2 1 2 1 OUTPUT 2 Using Relays Direct connection to a panel output Connecting inputs I N P U T 8 7 6 5 4 3 2 1 M 2 1 8 7 6 5 4 3 2 1 D C B A RC815 red wire With Advisor CD34 72 panels RD5045 option ...

Page 11: ... Every possibility mentioned above is added after accepting Account numbers Program an account number of up to 8 digits Some central stations keep their account nos to a maximum of 4 figures In this case do not program more than 4 figures Protocol Receiving protocol of the central station and or other receiving facility SIA Conforms to the SIA protocol level 1 300Bd FSK in accordance with the Amer...

Page 12: ...is way the telephone number can be extended to 21digits 3 1 5 Previous menu This menu option returns you to the first column of the menu structure 3 2 Dialling options This part of the program relates to the dialling formats available and the types of dialling tones on the telephone lines 3 2 1 Pulse Tone dialling Pulse dial or DTMF touch tone dialling must be selected in accordance with the param...

Page 13: ...ware input as the extension If hardware input 2 reports an HA event the central station will receive HA02 A test call generated by the dialler will be reported as RP00 a low voltage at the power input of the dialler is reported as YT00 If these events are forwarded to a hardware input the input number is added as an extension It is therefore possible to generate a test message or low voltage alarm...

Page 14: ...e opens These reactions can be reversed by setting an input to be normally closed 1 Press or until the cursor is under the input to be altered 12345678 2 Next press 0 to make the selected input to operate as normally closed 12 45678 3 This option can be reversed by repeating steps 1 and 2 3 3 4 Delayed events The input numbers are displayed on the keypad which must be active for a certain length o...

Page 15: ... BA02 Ack NUL Ack Yes 3 5 2 Fast Format The dialler can report to 8 or 16 channel fast format receivers The dialler automatically switches to 16 if an event is assigned to one of the 9 to 16 channels Channel options This is the part of the program where you select the channels on which the different events should be reported For example if you want an activation of a burglar alarm only to be repor...

Page 16: ...0 HA E 121 01 0 HR R 121 01 0 PA E 122 01 0 PR R 122 01 0 FA E 110 01 0 FR R 110 01 0 MA E 100 01 0 MR R 100 01 0 ZA E 150 01 0 ZR R 150 01 0 CG R 441 01 0 OP E 401 01 0 CL R 401 01 0 OP E 401 01 0 RP 1 E 602 01 0 AT E 301 01 0 AR R 301 01 0 YT E 302 01 0 YR R 302 01 0 YS 1 E 354 01 0 BV E 132 01 0 BW R 132 01 0 OR 1 E 406 01 0 Internally generated events RP 1 E 602 01 999 RX 1 E 601 01 999 YT E 3...

Page 17: ...e At this prompt select a message number for the event Start recording Start recording the message Procedure I Connect a standard telephone to the RJ11 telephone connector on the voice module see fig 3 II Press Enter to start recording the message A counter on the keypad display indicates the number of seconds of recording time left III Push button PB1 on the voice module to start to record the fi...

Page 18: ... 3 6 1 Test delay hh Set a delay time before the first automatic test call is sent to the central station In this way the test calls can be programmed a few days in advance max 24 hours to occur at a particular time in the week Example You program the automatic test call for every 24 hours and you want the test call to be re ceived at the central station at 03 00 hrs If you exit the installation a...

Page 19: ...al Station active upon alarm restore duration 20 sec Tabel 2 3 7 3 Latch output This option determines whether the output pulses or latches Pulse The output is activated for 4 seconds if triggered by the relevant event Latch FTC Line monitoring the output monitors the line status F T C the output activates when no connection is possible and is restored at the next successful connection ALI The out...

Page 20: ... 9 Line monitoring TD8803 TD8812 only The dialler has extensive line monitoring capabilities which can detect the following conditions lost connec tion engaged and incoming call signal 3 9 1 Line monitor ON OFF Toggles line monitoring on and off When line monitoring is ON and a fault is detected on the line the dialler will not attempt to dialuot and activates the FTC output 3 9 2 Telephone line o...

Page 21: ...ne number 1 This number must however be programmed with Voice protocol 4 2 Service telephone number The user may enter the Remote telephone number of the engineer and press Accept 4 3 Start dialling Automatically dials the Service telephone number of an engineer 4 4 User code If desired a new user code can be programmed to provide access to the user menu ...

Page 22: ... Central Station 3 CS3 Teleph Nbr CS3 Acc Nbr Protocol CS3 SIA Previous Menu Fast format CID Pager Voice Central Station 4 CS4 Teleph Nbr CS4 Acc Nbr Protocol CS4 SIA Previous Menu Fast format CID Pager Voice Central Station 5 CS5 Teleph Nbr CS5 Acc Nbr Protocol CS5 SIA Previous Menu Fast format CID Pager Voice Central Station 6 CS6 Teleph Nbr CS6 Acc Nbr Protocol CS6 SIA Previous Menu Fast format...

Page 23: ... Input 2 Input 3 Input 4 Input 5 Input 6 Input 7 Input 8 Previous Menu Restores Restore 1 8 Trigger NO or NC N Open 1 8 Delayed Events Delayed 1 8 Event Delay Seconds 15 Previous Menu Report Options BA 123456 BA BB TA HA PA FA MA ZA YS 123456 CG CL RP AT YT YS BV OR Previous Menu Protocol Options SIA 1 Ackn event Yes No Fast format Channels Options Handshake 1400 1600 Hz Previous Menu ...

Page 24: ...s Menu Previous Menu Test Call Test wait time Hours hhh Test Call time Hours hhh Always Test Yes No Manual Test Tel no 1 test Tel no 2 test Tel no 3 test Tel no 4 test Tel no 5 test Tel no 6 test Previous Menu Output Options Previous Menu Restore Ch 3 FTC Line fault Miscellaneous Function O P 1 FTC Line fault Audio Listen in Audio Listen in Call C station Function O P 2 FTC Line fault Audio Listen...

Page 25: ...ter Key Stop 4321 User Code Leave Dialler Programming Map Remote Programme Answer Enter Key Stop Service Acc Nbr Stop Previous Menu Line Monitor Line Mon On Off Options Accept off hook Always Linefault LF in alarm Ans Rng in alrm Answer Ring Dont Ans Ringing Previous Menu Leave Dialler ...

Page 26: ...ialling tone YES NO Interval between dialling attempts Call interval 5 sec 60 sec Interval between two series of dialling attempts 0 99 minuten Retry period Minutes 00 Dialling attempts per number 1 12 Number 12 FTC Dialling attempts before message fault 1 15 Number 10 6 3 SIA INPUTS Type of alarm per input Event selection TD8412 TD8812 Input Type 1 2 3 4 5 6 7 8 BA Burglar Alarm BB Burglar Inhibi...

Page 27: ... 4 5 6 7 8 Restore message for Input Restores Trigger on NO or NC N Open 12345678 Delayed Input Event Delay_ _ _ _ _ _ _ _ Delay 1 99 seconds seconds 15 6 4 REPORT OPTIONS Type of alarm report to telepho nenumber Central Station Telephone Number Type 1 2 3 4 5 6 BA Burglar Alarm BB Burglar Bypass TA Tamper Alarm HA Hold up Alarm PA Panic Alarm FA Fire Alarm MA Medical Alarm ZA Technical Alarm CG P...

Page 28: ...pe 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 BA BB TA HA PA FA MA ZA CG CL RP AT YT YS BV OR Handshake Fast Format Handshake type 1400 1600 Fast Format Channel Options TD8403 TD8803 Type 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 BA BB TA HA PA FA MA ZA CG CL RP AT YT YS BV OR Handshake Fast Format Handshake type 1400 1600 ...

Page 29: ...00 254 hours 024 Test cal Exclusive Always test YES NO 6 7 MISCELLANEOUS Output 1 function only TD8803 TD8812 FTC line fault Output 2 function only TD8803 TD8812 FTC line fault Latch output Latch 1 and or 2 _ _ Engineer code default 7812 7812 6 8 REMOTE PROGRAMMING Service access no 6 9 LINE MONITORING Line monitoring Guard OFF ON Telephone line options Accept Off Hook Always LF Line fault in alar...

Page 30: ... 30 ...

Page 31: ... 31 ...

Page 32: ... 32 Aritech reserves the right to change specifications without notice 14 2406 999 1 Aritech is an ISO9001 certified manufacturer ...

Reviews: