- 11 -
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
3. DIALLER ENGINEER MENU
Enter the engineer code 07812 to access the engineer menu. To exit from the engineer menu, press end
x
until [LEAVE DIALLER] appears, then press Accept
.
. When the dialer is connected to the CS350 or
an Advisor CD34 or CD72 panel, the engineer code can be entered when the time or date is displayed.
*
See Appendix A for Programming map.
3.1 Telephone / Account numbers
3.1.1 Central station 1 to 6
• Telephone numbers
Program up to six separate central station telephone numbers. An account number MUST be programmed
for each Central Station telephone number.
OPTIONS
Function
Press
Display
5 seconds pause
£
+
¢
P
Wait for dialling tone
£
+
¢
, then
£
t
Delete Central station 1 number
£
+
¢
, then
0
,
.
,
X
Central station 1
Every possibility mentioned above is added after accepting
• Account numbers
• Program an account number of up to 8 digits.
*
Some central stations keep their account nos. to a maximum of 4 figures.In this case, do
not program more than 4 figures.
• Protocol
• Receiving protocol of the central station and / or other receiving facility.
- SIA:
Conforms to the SIA protocol level 1(300Bd / FSK) in accordance with the American SIA
standard.
- Fast Format:
Aritech 8 or 16 channel DTMF protocol: the handshake frequency can be set up using
the "Protocol Options" menu (1400 or 1600 Hz).
- CID:
The contact ID protocol. The data is transmitted using DTMF.
- Paging:
Sends a message, consisting of a maximum of 14 characters, to a Semadigit receiver.
The message is programmed using the "Protocol Options" menu.
- Voice:
Sends one or more previously recorded messages (maximum 4 messages) to a
telephone. The messages are programmed using the ‘Protocol Options’ menu.