Aritech ACL585 Installation Sheet Download Page 4

 

4 / 16 

 

P/N 466-5611-

ML • REV A • ISS 30JUL21 

Option 

Description 

Add/change user or master code

 

To change master code, enter user number 000 followed by 
the new master code (1 to 8 digits). 

To add or change existing user, enter the user number (001 
to 999), and a new user code (1 to 8 digits) 

The new user is assigned to Relay 1 

Set Relay 1 timer

 

To set toggle relay mode, press 00.  

To set time in seconds, press 01 to 99. 

The default time is 03 seconds. 

Set Relay 2 timer

 

To set toggle relay mode, press 00.  

To set time in seconds, press 01 to 99. 

The default time is 03 seconds. 

Assign output to the user 

Enter the user number (001 to 999). Next, press 1 for Relay 
1, and/or 2 for Relay 2.

 

Not used 

Slave device 

Press 2 to set ACL870FL-PB or ACL870SU-PB as a slave 
device.

 

Buzzer, backlight, read range 

Press 0 to set buzzer off, or 1 to on. Press 2 to for backlight 
off, or 3 to on. Press 4 for backlight on key press, or 5 for 
dimmed backlight. 

The default values are the following: buzzer on, dimmed 
backlight.

 

Not used 

Delete all users 

Press 999 to confirm.

 

Delete single user 

Enter user number from 001 to 999.

 

Next, proceed from the step 4 above 

– press A to validate the 

change. 

Example 

To assign user code 12345 to the user 5, and relay 2 that 
activates for 4 seco nds, assuming default master code 000: 

Press 000, B, then 0, 005, 12345, A. Press 3, 005, 2, A. 
Press 2, 04, A. Press B to exit the programming mode. 

Specifications 

Power supply 

12 to 24 V AC/DC 

Current consumption 

max. 70 mA 

Outputs 

1 relay: 2 A at 24 V AC/DC 

User capacity 

1000 

PIN length 

1 to 8 digits 

RTE inputs 

Buzzer, backlight control  Via menu settings 

Tamper 

Yes 

Door open time 

0 to 99 s, or toggle (on/off mode) 

IP 

IP65 

Operating Temperature 

−20 to +50°C, without condensation 

Firmware upgrade 

Via RS485 converter 

Security 

30-second lockout after 8 consecutive 
invalid PINs 

Regulatory information 

Manufacturer 

PLACED ON THE MARKET BY: 
Carrier Fire & Security Americas Corporation, Inc. 
13995 Pasteur Blvd 
Palm Beach Gardens, FL 33418, USA 

AUTHORIZED EU REPRESENTATIVE: 
Carrier Fire & Security B.V. 
Kelvinstraat 7, 6003 DH Weert, Netherlands 

Product warnings 
and disclaimers 

 

THESE PRODUCTS ARE INTENDED FOR SALE 
TO AND INSTALLATION BY QUALIFIED 
PROFESSIONALS. CARRIER FIRE & 
SECURITY CANNOT PROVIDE ANY 
ASSURANCE THAT ANY PERSON OR ENTITY 
BUYING ITS PRODUCTS, INCLUDING ANY 
“AUTHORIZED DEALER” OR “AUTHORIZED 
RESELLER”, IS PROPERLY TRAINED OR 
EXPERIENCED TO CORRECTLY INSTALL FIRE 
AND SECURITY RELATED PRODUCTS. 

For more information on warranty disclaimers and 
product safety information, please check 
https://firesecurityproducts.com/policy/product-
warning/ o
r scan the QR code. 

Certification 

 

 

Carrier Fire & Security hereby declares that this 
device is in compliance with the applicable 
requirements and provisions of the Directive 
2014/30/EU and/or 2014/35/EU. For more 
information see firesecurityproducts.com or 
www.aritech.com. 

REACH 

Product may contain substances that are also 
Candidate List substances in a concentration 
above 0.1% w/w, per the most recently published 
Candidate List found at ECHA Web site. 

Safe use information can be found at 
https://firesecurityproducts.com/en/content/intrusi
on-intro 

 

2012/19/EU (WEEE directive): Products marked 
with this symbol cannot be disposed of as 
unsorted municipal waste in the European Union. 
For proper recycling, return this product to your 
local supplier upon the purchase of equivalent 
new equipment, or dispose of it at designated 
collection points. For more information see: 
recyclethis.info 

Product 
documentation 

 

Please consult the following web link to retrieve 
the electronic version of the product 
documentation. 

This link will guide you to the EMEA regional 
contact page. On this page you can request your 
login to the secured web portal where all manuals 
are stored. 

https://firesecurityproducts.com/en/contact 

Contact information 

firesecurityproducts.com or www.aritech.com 

Summary of Contents for ACL585

Page 1: ...mm A B RS 485 max 50 m ACL870FL PB ACL870SU PB Red LED Relay Status Output 2 in ACL870FL PB Orange LED Key press and Menu Green LED Relay Status Output 1 1 2 3 Push Button 12 24V NC COM NO T1 Tamper 6 Orange 5 Blue 10 Yellow 1 Red 2 Black 3 Pink 4 Violet 7 Brown 8 Green 11 White GND PB R 485 A S R 485 B S AC DC 9 Gray T2 Relay 2 A Power supply ...

Page 2: ... T2 8 Green Relay 2 A NC 9 Gray COM 10 Yellow NO 11 White B 485 RS A 485 RS Exit Button NO 1N4007 12 VDC 12V 12V GND GND G N D P 1 B N 1 O COM 1 2 Black Red Pink Violet 12 VDC 1N4001 Diode N 2 C V V Orange Blue Yellow Red Black Pink Violet Brown Green White Gray ACL870FL SU 12 O N 12 VDC 1N4007 Black Red Pink Violet Black Brown Pink Violet Red White Yellow COM NO GND 12V out A 485 RS B 485 RS max ...

Page 3: ... Reset master code Caution Resetting the master code will delete all user codes Resetting the master code will also unpair ACL870FL PB and ACL870SU PB See figure 5 1 Disconnect power and set DIP switch 1 to On Figure 7 item 1 2 Reconnect power The keypad beeps continuously 3 Set DIP switch 1 to off Orange LED switches on long beep sounds 4 Press 000 5 Enter the new master code 1 to 8 digits 6 Pres...

Page 4: ...tory information Manufacturer PLACED ON THE MARKET BY Carrier Fire Security Americas Corporation Inc 13995 Pasteur Blvd Palm Beach Gardens FL 33418 USA AUTHORIZED EU REPRESENTATIVE Carrier Fire Security B V Kelvinstraat 7 6003 DH Weert Netherlands Product warnings and disclaimers THESE PRODUCTS ARE INTENDED FOR SALE TO AND INSTALLATION BY QUALIFIED PROFESSIONALS CARRIER FIRE SECURITY CANNOT PROVID...

Page 5: ...tzercodes gelöscht Durch das Zurücksetzen des Mastercodes werden auch das ACL870FL PB und das ACL870SU PB entkoppelt Siehe Abbildung 5 1 Trennen Sie die Stromversorgung und stellen Sie DIP Schalter 1 auf On Abbildung 7 Position 1 2 Stellen Sie die Stromversorgung wieder her Das Bedienteil piept kontinuierlich 3 Stellen Sie DIP Schalter 1 auf Off Die orangefarbene LED leuchtet ein langer Signalton ...

Page 6: ...die Änderung zu bestätigen Beispiel So weisen Sie mit dem Standard Mastercode 000 Benutzer 5 den Benutzercode 12345 und Relais 2 zu das 4 Sekunden lang aktiviert wird Drücken Sie 000 B dann 0 005 12345 A Drücken Sie 3 005 2 A Drücken Sie 2 04 A Drücken Sie B um den Programmiermodus zu verlassen Technische Daten Stromversorgung 12 bis 24 V AC DC Stromaufnahme max 150mA Ausgänge 1 Relais 2 A bei 24 ...

Page 7: ...sa RS485 B 4 Violeta Pulsador GND 5 Azul PB 6 Naranja Tamper T1 7 Marrón T2 8 Verde Relé 2 A NC 9 Gris COM 10 Amarillo NO 11 Blanco Indicadores LED Consulte la figura 3 En el teclado hay tres indicadores LED Rojo elemento 1 estado del relé 2 en el ACL870FL PB Verde elemento 2 estado del relé 1 Naranja elemento 3 pulsación de teclas y menú Conmutadores DIP Consulte la figura 7 1 Restablecer el códi...

Page 8: ...lse de 01 a 99 El tiempo predeterminado es de 03 segundos 3 Asignar salida al usuario Introduzca el número de usuario de 001 a 999 A continuación pulse 1 para el relé 1 o 2 para el relé 2 4 No utilizado 5 Dispositivo secundario Pulse 2 para configurar ACL870FL PB o ACL870SU PB como dispositivo secundario Opción Descripción 6 Zumbador luz de fondo y rango de lectura Pulse 0 para desactivar el zumba...

Page 9: ...ducto a su representante de ventas local al comprar un equipo nuevo similar o deséchelo en los puntos de recogida designados Para obtener más información consulte recyclethis info Documentación de producto Por favor consulte el siguiente enlace Web para recuperar la versión electrónica de la documentación del producto Este enlace le guiará a su página de contacto local de EMEA En esta página puede...

Page 10: ...Option Description 0 Ajouter modifier un code maître ou d utilisateur Pour modifier le code maître saisissez le numéro d utilisateur 000 suivi du nouveau code maître 1 à 8 chiffres Pour ajouter ou modifier un utilisateur existant saisissez le numéro d utilisateur 001 à 999 et un nouveau code d utilisateur 1 à 8 chiffres Le nouvel utilisateur est affecté au relais 1 1 Régler la temporisation du rel...

Page 11: ...es à une concentration supérieure à 0 1 p p selon la Liste de substances candidates la plus récente publiée sur le site web de l Agence européenne des produits chimiques ECHA Vous trouverez des renseignements sur l utilisation sécuritaire du produit à l adresse https firesecurityproducts com en content intrusi on intro 2012 19 EU WEEE Les produits marqués de ce symbole peuvent pas être éliminés co...

Page 12: ...ammazione più sotto 4 Premere A per convalidare la modifica Se la modifica non è valida la tastiera emette diversi segnali acustici brevi e il LED arancione lampeggia rapidamente Tornare al punto 3 Se la modifica è valida viene confermata da 2 segnali acustici brevi Tornare al punto 3 Per uscire dalla modalità di programmazione premere B in qualsiasi fase della modalità di programmazione Il LED ar...

Page 13: ...eseguire la scansione del codice QR Certificazione Direttive Unione Europea Carrier Fire Security dichiara che questo dispositivo è conforme ai requisiti applicabili e alle disposizioni della Direttiva 2014 30 UE e o 2014 35 UE Per ulteriori informazioni vedere firesecurityproducts com o www aritech com REACH Il prodotto può contenere sostanze che sono anche sostanze appartenenti all elenco di can...

Page 14: ...egd bent om de programmeermodus te openen zendt het codeslot meerdere korte pieptonen uit en het oranje ledlampje knippert snel Als de code geldig is wordt de programmeermodus gesignaleerd door 1 korte en 1 lange pieptoon en blijft het oranje ledlampje branden U kunt doorgaan met programmeren 3 Voer het optienummer in dat u wilt wijzigen Raadpleeg Programmeeropties hieronder 4 Druk op A om de wijz...

Page 15: ...wingen en disclaimers met betrekking tot de producten DEZE PRODUCTEN ZIJN BEDOELD VOOR VERKOOP AAN EN INSTALLATIE DOOR GEKWALIFICEERDE BEROEPSKRACHTEN CARRIER FIRE SECURITY GEVEN GEEN GARANTIE DAT EEN PERSOON OF ENTITEIT DIE DIENS PRODUCTEN AANSCHAFT WAARONDER GEAUTORISEERDE DEALERS OF GEAUTORISEERDE WEDERVERKOPERS OP DE JUISTE WIJZE ZIJN OPGELEID OF VOLDOENDE ERVARING HEBBEN OM PRODUCTEN MET BETR...

Page 16: ...16 16 P N 466 5611 ML REV A ISS 30JUL21 ...

Reviews: