Setting and operating mode of zone 1 and 
zone 2 managed with Room Thermostat

-  Press the heating circuit operating 

mode button (2) 

-   Turn the knob (5) and select the desired 

zone

-  Press the OK button (6) to confi rm
-  Press the heating circuit operating 

mode button (2) to select the desired 
operating mode

-  Press the OK button (6) to confi rm
NOTE: it is necessary to have a heating 
request (TA closed).

Setting and operating mode of zone 3 
managed with Room Thermostat
(zone 3 enabled on parameter 5890 set to 
“Heat circuit pump HCP Q20” value)

-  Press the OK button (6) once
-  Press the INFO button (3) until the 

“menu list” appears

-  Turn the knob (5) and select the 

Installateur

” menu

-  Press the OK button (6) to confi rm
-   Turn the knob (5) and select “heating 

circuit P” 

-  Press the OK button (6) to confi rm
-  Turn the knob (5) and select the 

“1300 

operating mode” parameter

-  Press the OK button (6) to confi rm
-  Turn the knob (5) and select the desired 

operating mode

-  Press the OK button (6) to confi rm

NOTE:
If zone management is performed via 
remote control QAA75, the operating mode 
must be set on the remote control itself.

1.

2.

3.

4.

5.

6.

7.

8.

TA

(ROOM THERMOSTAT)

TA

(ROOM THERMOSTAT)

ZONE 1

(INTERNAL UNIT 1 

QAA75)

ZONE 2

(INTERNAL UNIT 2

QAA75)

ZONE 3

(INTERNAL UNIT P 

QAA75)

n

n

n

n

n

k

h

f

b

b

b

a

n

p

p

M BX4 M BX3 M H3 M B12 M BX2 M BX1 M B1 M H1 M B9 M B3

M

MB DB

XBD

BSB

LPB

B2

G+CL-CL+CL-CL+CL-CL+

Summary of Contents for RVS 63

Page 1: ...genuine original accessories Istruzioni operative Operating Instructions RVS 63 CASCADE MANAGER 3590475 420010550500 09 2013...

Page 2: ...mounting instructions pg 3 Peripherals connection pg 4 Product description pg 7 Management of zone control devices pg 8 Electrical diagrams pg 10 Parameter setting pg 18 Temperature adjustment curve...

Page 3: ...ave been connected replace the cover from bottom to top and secure it with the 6 screws so that the bristle strip remains inside the temperature adjuster body Proceed with the initial start up and par...

Page 4: ...t gure for setting the addresses IMPORTANT The identi cation numbers must be entered in succession always starting from boiler number 1 Diagnostics LEDs C and D OFF cascade interface not connected LED...

Page 5: ...button Turn the knob to scroll the list and verify that Gateway LPB appears among the available devices CHAFFOTEAUX TOP MODELS Press the OK button and CODE will ap pear on the display Press the OK bu...

Page 6: ...win dows which could affect the temperature readings It should be installed approximately 1 5 me tres above the oor level Installation In case of wall mounting suf cient space must be left above the...

Page 7: ...xx ECO INFO 1 2 PROG No 7 Manual operation button Pressing the button engages the manual operating mode all pumps function the mixing valve is no longer controlled and the burner is set to 60 C the sc...

Page 8: ...eter 42 Heating circuit 1 Parameter 42 Heating circuit 2 Parameter 5951 NC Electrical connection CL CL Electrical connection CL CL Electrical connection H1 M QAA75 Room thermostat QAA75 Parameter 40 I...

Page 9: ...button 3 until the menu list appears Turn the knob 5 and select the Installateur menu Press the OK button 6 to con rm Turn the knob 5 and select heating circuit P Press the OK button 6 to con rm Turn...

Page 10: ...3 M MB DB XBD BSB LPB B2 G CL CL CL CL CL CL B9 OUTDOOR PROBE RVS CASCADE MANAGER B2 MANIFOLD PROBE T2 T1 BOILER 1 CONNECTION QX4 FX4 BOILER 2 CONNECTION RVS B9 B2 TA COMPENSATOR TA GENERIC BOILERS DI...

Page 11: ...M UX M BX4 M BX3 M H3 M B12 M BX2 M BX1 M B1 M H1 M B9 M B3 M MB DB XBD BSB LPB B2 G CL CL CL CL CL CL B9 OUTDOOR PROBE RVS CASCADE MANAGER BX1 MANIFOLD PROBE BUS BOILER CONNECTION RVS B9 BX1 BUS BUS...

Page 12: ...n n k h f b b b a n p p M UX M BX4 M BX3 M H3 M B12 M BX2 M BX1 M B1 M H1 M B9 M B3 M MB DB XBD BSB LPB B2 G CL CL CL CL CL CL B9 OUTDOOR PROBE RVS CASCADE MANAGER BX1 MANIFOLD PROBE B12 ZONE 2 PROBE...

Page 13: ...N Y2 Y1 N Q6 N QX1 N Q2 N Q3 SK2 SK1 4 S3 T2 T1 L1 N S3 L1 L1 N L P Q R S T U T S U U Z N n n n n n n k h f b b b a n p p M UX M BX4 M BX3 M H3 M B12 M BX2 M BX1 M B1 M H1 M B9 M B3 M MB DB XBD BSB L...

Page 14: ...AMETER DESCRIPTION VALUE Engineer Con guration 5715 Heating circuit 2 zone 5 activation On Engineer Con guration 5890 Relay output QX1 activation of zone 6 management Heat circuit pump HCP Q20 Enginee...

Page 15: ...p p M UX M BX4 M BX3 M H3 M B12 M BX2 M BX1 M B1 M H1 M B9 M B3 M MB DB XBD BSB LPB B2 G CL CL CL CL CL CL RVS 2 CASCADE MANAGER B12 ZONE 5 PROBE B1 ZONE 4 PROBE QX4 QX3 N N QX4FX4 EX2 QX2 N Y6 Y5 N Y...

Page 16: ...n n n n n k h f b b b a n p p M UX M BX4 M BX3 M H3 M B12 M BX2 M BX1 M B1 M H1 M B9 M B3 M MB DB XBD BSB LPB B2 G CL CL CL CL CL CL B9 OUTDOOR PROBE RVS BOILER CONNECTION BX1 MANIFOLD PROBE B3 STORAG...

Page 17: ...IRCULATION PROBE BX1 MANIFOLD PROBE B3 STORAGE CYLINDER PROBE BUS BOILER CONNECTION RVS CASCADE MANAGER B9 OUTDOOR PROBE BX1 MANIFOLD PROBE BUS BUS LPB COMPENSATOR BUS BUS LPB Q3 STORAGE CYLINDER CIRC...

Page 18: ...ummer winter heating limit C 30 0 C deactivated 20 0 C 1040 Heating circuit 2 Flow temp setpoint min 8 C at par 1041 8 C 1041 Heating circuit 2 Flow temp setpoint max par 1041 at 95 C 80 C Engineer 3...

Page 19: ...til storage cylinder lling is completed None storage cylinder simultaneous to heating MC shifting PC absolute the direct circuits remain blocked until lling of the DHW storage cylinder is completed Wh...

Page 20: ...s the ow temperature in a uniform manner along the entire outdoor temperature range If the room temperature is generally too warm or too cold it must be corrected through a parallel displacement of th...

Page 21: ...ent DC 3 mA H1 H3 analogue inputs Safety low voltage Work range DC 0 10 V Internal resistance 100 k Probe input B9 NTC1k QAC34 probe inputs B1 B2 B3 B12 BX NTC10k QAZ36 QAD36 Cables allowed for probe...

Page 22: ...23 Connexions p riph riques page 24 Description du produit page 27 Gestions des dispositifs de contr le des zones page 28 Sch mas des installations page 30 Param trage des sch mas page 38 Courbe de th...

Page 23: ...ssant vers le haut et le xer l aide des 6 vis en faisant en sorte que le joint brosse se trouve l int rieur du corps du r gulateur Proc der pr sent la mise en service et au param trage des circuits de...

Page 24: ...s num ros d identi cation doivent tre ins r s les uns la suite des autres en commen ant toujours par la chaudi re num ro 1 Diagnostic Led C et D TEINTES interface de cascades pas connect e Led C ALLUM...

Page 25: ...e OK Tourner le bouton pour faire d ler la liste et v ri er que parmi les dispositifs il y ait bien Gateway LPB MOD LES CHAFFOTEAUX TOP Appuyer sur OK L cran af che CODE Appuyer sur la touche OK Tourn...

Page 26: ...xt rieur qui pourraient in uencer son fonctionne ment Il faut l installer environ 1m50 au dessus du sol Installation En cas d installation murale il faut pr voir suf samment de place au dessus de l un...

Page 27: ...2 PROG No 7 Touche fonctionnement manuel Appuyer sur la touche pour ins rer le fonctionnement manuel toutes les pompes sont en marche le m langeur n est plus command et le br leur est r gl sur 60 C l...

Page 28: ...Circuit chauffage 1 Param tre 42 Circuit chauffage 2 Param tre 5951 NF Connexion lectrique CL CL Connexion lectrique CL CL Connexion lectrique H1 M QAA75 Thermostat d ambiance QAA75 Param tre 40 Unit...

Page 29: ...ance zone 3 activ e sur le param tre 5890 r gl sur la valeur Pompe CCP Q20 Appuyer une fois sur OK 6 Appuyer sur la touche INFO 3 jusqu af chage de liste menus Tourner le bouton 5 et s lectionner le m...

Page 30: ...B B2 G CL CL CL CL CL CL B9 SONDE EXTERIEURE RVS R GULATEUR CASCADE B2 SONDE CAPTEUR T2 T1 RACCORDEMENT CHAUDI RE 1 QX4 FX4 RACCORDEMENT CHAUDI RE 2 RVS B9 B2 TA COMPENSATEUR TA SCH MA CHAUDI RES G N...

Page 31: ...BX4 M BX3 M H3 M B12 M BX2 M BX1 M B1 M H1 M B9 M B3 M MB DB XBD BSB LPB B2 G CL CL CL CL CL CL B9 SONDE EXT RIEURE RVS R GULATEUR CASCADE BX1 SONDE CAPTEUR BUS RACCORDEMENT CHAUDI RE RVS B9 BX1 BUS...

Page 32: ...b b b a n p p M UX M BX4 M BX3 M H3 M B12 M BX2 M BX1 M B1 M H1 M B9 M B3 M MB DB XBD BSB LPB B2 G CL CL CL CL CL CL B9 SONDE EXTERIEURE RVS R GULATEUR CASCADE BX1 SONDE CAPTEUR B12 SONDE ZONE 2 B1 S...

Page 33: ...Q6 N QX1 N Q2 N Q3 SK2 SK1 4 S3 T2 T1 L1 N S3 L1 L1 N L P Q R S T U T S U U Z N n n n n n n k h f b b b a n p p M UX M BX4 M BX3 M H3 M B12 M BX2 M BX1 M B1 M H1 M B9 M B3 M MB DB XBD BSB LPB B2 G CL...

Page 34: ...MENU PARAM TRE DESCRIPTIF VALEUR Sp cialiste Con guration 5715 Circuit chauffage 2 validation zone 5 On Sp cialiste Con guration 5890 Sortie relais QX1 validation gestion zone 6 Pompe CCP Q20 Sp ciali...

Page 35: ...3 M B12 M BX2 M BX1 M B1 M H1 M B9 M B3 M MB DB XBD BSB LPB B2 G CL CL CL CL CL CL RVS 2 R GULATEUR CASCADE B12 SONDE ZONE 5 B1 SONDE ZONE 4 QX4 QX3 N N QX4FX4 EX2 QX2 N Y6 Y5 N Y2 Y1 N Q6 N QX1 N Q2...

Page 36: ...h f b b b a n p p M UX M BX4 M BX3 M H3 M B12 M BX2 M BX1 M B1 M H1 M B9 M B3 M MB DB XBD BSB LPB B2 G CL CL CL CL CL CL B9 SONDE EXTERIEURE RVS RACCORDEMENT CHAUDI RE BX1 SONDE CAPTEUR B3 SONDE BALL...

Page 37: ...TION BX1 SONDE CAPTEUR B3 SONDE BALLON BUS RACCORDEMENT CHAUDI RE RVS R GULATEUR CASCADE B9 SONDE EXT RIEURE BX1 SONDE CAPTEUR BUS BUS LPB COMPENSATEUR BUS BUS LPB Q3 CIRCULATEUR BALLON VNR B3 SONDE B...

Page 38: ...t hiver C 30 0 C d sactiv 20 0 C 1040 Circuit chauffage 2 Valeur de consigne de d part min 8 C au par 1041 8 C 1041 Circuit chauffage 2 Valeur de consigne de d part max par 1041 95 C 80 C Sp cialiste...

Page 39: ...n est pas termin Sans ballon en parall le au chauffage CC Glissante CCP absolue les circuits directs restent bloqu s tant que le chargement du ballon ECS n est pas termin Quand la puissance thermique...

Page 40: ...ourbe caract ristique modi e la temp rature de d part de fa on uniforme sur toute la plage de temp ratures ext rieures Si la temp rature ambiante est en g n ral trop chaude ou trop froide il faut fair...

Page 41: ...DC 3 mA Entr es analogiques H1 H3 Basse tension de s curit Plage de travail DC 0 10 V R sistance int rieure 100 k Entr e sonde B9 NTC1k QAC34 Entr es sonde B1 B2 B3 B12 BX NTC10k QAZ36 QAD36 C bles ad...

Page 42: ...pared p g 43 Conexiones perif ricas p g 44 Descripci n del producto p g 47 Gestiones dispositivos de control de zonas p g 48 Esquemas de las instalaciones p g 50 Parametrizaci n esquemas p g 58 Curva...

Page 43: ...conexi n de todos los cables colocar la tapa de abajo hacia arriba y jarla con los 6 tornillos de modoquelafranjadecerdasseencuentre dentro del cuerpo del regulador Realizar luego la puesta en servici...

Page 44: ...terfaz cascadas no conectada Led C ENCENDIDO interfaz cascadas alimentada Led D intermitente comunicaci n LPB presente Led D APAGADO comunicaci n LPB ausente Conexi n entre tarjeta interfaz cascadas y...

Page 45: ...n OK Girar el mando para pasar la lista y com probar que entre los dispositivos sea visible Gateway LPB MODELOS CHAFFOTEAUX TOP Presionar el bot n OK el display muestra CODE Presionar el bot n OK Gir...

Page 46: ...uras que pudiesen in uenciar dicha medici n Instalarlo a aproximadamente 1 50 m de al tura del piso Instalaci n Si se monta en la pared se deber prever el espacio su ciente por encima de la unidad que...

Page 47: ...G No 7 Bot n de funcionamiento manual Presionando el bot n se introduce el funcionamiento manual todas las bombas est n en funcionamiento el mezclador ya no es comandado y el quemador es regulado a 60...

Page 48: ...de calefacci n 1 Par metro 42 Circuito calefacci n 2 Par metro 5951 NC Conexi n el ctrica CL CL Conexi n el ctrica CL CL Conexi n el ctrica H1 M QAA75 Termostato de ambiente QAA75 Par metro 40 Unidad...

Page 49: ...habilitada en el par metro 5890 programado en el valor Bomba CRP Q20 Presionar una vez el bot n OK 6 Presionar el bot n INFO 3 hasta visualizar lista men Girar el mando 5 y seleccionar men Ingenier a...

Page 50: ...PB B2 G CL CL CL CL CL CL B9 SONDA EXTERNA RVS ADMINISTRADOR CASCADACASCATA B2 SONDA COLECTOR T2 T1 CONEXI N CALDERA 1 QX4 FX4 CONEXI N CALDERA 2 RVS B9 B2 TA COMPENSADOR TA ESQUEMA CALDERAS GEN RICAS...

Page 51: ...4 M BX3 M H3 M B12 M BX2 M BX1 M B1 M H1 M B9 M B3 M MB DB XBD BSB LPB B2 G CL CL CL CL CL CL B9 SONDA EXTERNA RVS ADMINISTRADOR CASCADA BX1 SONDA COLECTOR BUS CONEXI N CALDERA RVS B9 BX1 BUS BUS LPB...

Page 52: ...a n p p M UX M BX4 M BX3 M H3 M B12 M BX2 M BX1 M B1 M H1 M B9 M B3 M MB DB XBD BSB LPB B2 G CL CL CL CL CL CL B9 SONDA EXTERNA RVS ADMINISTRADOR CASCADA BX1 SONDA COLECTOR B12 SONDA ZONA 2 B1 SONDA Z...

Page 53: ...N Q3 SK2 SK1 4 S3 T2 T1 L1 N S3 L1 L1 N L P Q R S T U T S U U Z N n n n n n n k h f b b b a n p p M UX M BX4 M BX3 M H3 M B12 M BX2 M BX1 M B1 M H1 M B9 M B3 M MB DB XBD BSB LPB B2 G CL CL CL CL CL C...

Page 54: ...METRO DESCRIPCI N VALOR Ingenier a Con guraci n 5 7 1 5 Circuito calefacci n 2 habilitaci n zona 5 On Ingenier a Con guraci n 5 8 9 0 Salida rel QX1 habilitaci n gesti n zona 6 Bomba CRP Q20 Ingenier...

Page 55: ...B12 M BX2 M BX1 M B1 M H1 M B9 M B3 M MB DB XBD BSB LPB B2 G CL CL CL CL CL CL RVS 2 ADMINISTRADOR CASCADA B12 SONDA ZONA 5 B1 SONDA ZONA 4 QX4 QX3 N N QX4FX4 EX2 QX2 N Y6 Y5 N Y2 Y1 N Q6 N QX1 N Q2...

Page 56: ...n n n k h f b b b a n p p M UX M BX4 M BX3 M H3 M B12 M BX2 M BX1 M B1 M H1 M B9 M B3 M MB DB XBD BSB LPB B2 G CL CL CL CL CL CL B9 SONDA EXTERNA RVS CONEXI N CALDERA BX1 SONDA COLECTOR B3 SONDA HERVI...

Page 57: ...CIRCULACI N BX1 SONDA COLECTOR B3 SONDA HERVIDOR BUS CONEXI N CALDERA RVS ADMINISTRADOR CASCADA B9 SONDA EXTERNA BX1 SONDA COLECTOR BUS BUS LPB COMPENSADOR BUS BUS LPB Q3 CIRCULADOR HERVIDOR VNR B3 SO...

Page 58: ...alefacci n 2 L mite calef inv verano C 30 0 C deshabilitado 20 0 C 1 0 4 0 Circuito calefacci n 2 Min consigna temp impulsi n 8 C en p rr 1041 8 C 1 0 4 1 Circuito calefacci n 2 M x consigna temp impu...

Page 59: ...del hervidor no ha terminado Ninguna hervidor en paralelo con la calefacci n MC variable PC absoluta los circuitos directos permanecen bloqueados hasta que la carga del hervidor ACS naliza Cuando la p...

Page 60: ...peratura de impulsi n de modo uniforme en toda la franja de temperaturas externas Si la temperatura ambiente es en general demasiado caliente o demasiado fr a corregir con un desplazamiento paralelo a...

Page 61: ...ado DC 3 mA Entradas anal gicas H1 H3 Baja tensi n de seguridad Campo de trabajo DC 0 10 V Resistencia interna 100 k Entrada sonda B9 NTC1k QAC34 Entradas sonda B1 B2 B3 B12 BX NTC10k QAZ36 QAD36 Cabl...

Page 62: ...a szerel shez 63 oldal Perif ri k csatlakoz sai 64 oldal A term k le r sa 67 oldal Z naellen rz berendez sek kezel se 68 oldal A berendez s rajzai 70 oldal A rajzok param terez se 78 oldal H szab lyoz...

Page 63: ...t majd r gz tse ezeket a k belr gz t kkel 4 bra Az sszes k bel csatlakoztat sa ut n helyezze fel a fedelet alulr l felfel s r gz tse a 6 csavarral gy hogy a s rt s cs k a szab lyoz test belsej ben leg...

Page 64: ...Az azonos t sz mokat egym s ut n kell megadni az 1 kaz nt l kezdve Diagnosztika KIKAPCSOLT C s D Led sorbakapcsolt interf sz nincs csatlakoztatva BEKAPCSOLT C Led bet pl lt sorbakapcsolt interf sz Vil...

Page 65: ...ellen rizze hogy a berendez sek k z tt l that legyen a Gateway LPB CHAFFOTEAUX TOP MODELLEK Nyomja meg az OK gombot a kijelz n megje lenik a CODE felirat Nyomja meg az OK gom bot A szervizk d 234 meg...

Page 66: ...kt l melyek befoly solhatj k a gy jt st t vol helyezze el A padl t l nagyj b l 1 50 m t vols gban sze relje be Beszerel s Falra szerel s eset n elegend helyet kell biztos tani az egys g felett mely le...

Page 67: ...b A gomb lenyom s ra bekapcsol a k zi funkci az sszes szivatty m k dik a kever nem vez relt s az g 60 C ra van be ll tva a kijelz n megjelenik a csavarh z szimb luma 8 K m nysepr funkci gomb E gomb ne...

Page 68: ...e changeover HCP 42 es param ter F t si k r 1 42 es param ter F t si k r 2 5951 es param ter NC Elektromos csatlakoz s CL CL Elektromos csatlakoz s CL CL Elektromos csatlakoz s H1 M QAA75 Szobatermosz...

Page 69: ...elen s ig Forgassa el a teker gombot 5 s v lassza ki a Tervez men t A j v hagy shoz nyomja meg az OK 6 gombot Forgassa el a teker gombot 5 s v lassza ki a P f t k rt A j v hagy shoz nyomja meg az OK 6...

Page 70: ...DB XBD BSB LPB B2 G CL CL CL CL CL CL B9 K LS RZ KEL RVS SORBAKAPCSOLT RENDSZER VEZ RL SE B2 GY JT CSONK RZ KEL T2 T1 KAZ N CSATLAKOZ SA 1 QX4 FX4 KAZ N CSATLAKOZ SA 2 RVS B9 B2 TA KOMPENZ TOR TA LTAL...

Page 71: ...M BX4 M BX3 M H3 M B12 M BX2 M BX1 M B1 M H1 M B9 M B3 M MB DB XBD BSB LPB B2 G CL CL CL CL CL CL B9 K LS RZ KEL RVS SORBAKAPCSOLT RENDSZER VEZ RL SE BX1 GY JT CSONK RZ KEL BUS KAZ N CSATLAKOZ SA RVS...

Page 72: ...b b b a n p p M UX M BX4 M BX3 M H3 M B12 M BX2 M BX1 M B1 M H1 M B9 M B3 M MB DB XBD BSB LPB B2 G CL CL CL CL CL CL B9 K LS RZ KEL RVS SORBAKAPCSOLTRENDSZERVEZ RL SE BX1 GY JT CSONK RZ KEL B12 2 Z N...

Page 73: ...N Y2 Y1 N Q6 N QX1 N Q2 N Q3 SK2 SK1 4 S3 T2 T1 L1 N S3 L1 L1 N L P Q R S T U T S U U Z N n n n n n n k h f b b b a n p p M UX M BX4 M BX3 M H3 M B12 M BX2 M BX1 M B1 M H1 M B9 M B3 M MB DB XBD BSB LP...

Page 74: ...RRAL A HASZN LATI MELEG V ZHEZ RVS 2 MEN PARAM TER LE R S RT K Tervez Konfigur ci 5715 F t si k r 2 5 z na aktiv l sa BE Tervez Konfigur ci 5890 Rel QX1 6 z na kezel s nek aktiv l sa CRP Q20 szivatty...

Page 75: ...B1 M H1 M B9 M B3 M MB DB XBD BSB LPB B2 G CL CL CL CL CL CL RVS 2 SORBAKAPCSOLT RENDSZER VEZ RL SE B12 5 Z NA RZ KEL B1 4 Z NA RZ KEL QX4 QX3 N N QX4FX4 EX2 QX2 N Y6 Y5 N Y2 Y1 N Q6 N QX1 N Q2 N Q3 S...

Page 76: ...n n n k h f b b b a n p p M UX M BX4 M BX3 M H3 M B12 M BX2 M BX1 M B1 M H1 M B9 M B3 M MB DB XBD BSB LPB B2 G CL CL CL CL CL CL B9 K LS RZ KEL RVS KAZ N CSATLAKOZ SA BX1 GY JT CSONK RZ KEL B3 FORRAL...

Page 77: ...X2 VISSZAKERINGTET RZ KEL BX1 GY JT CSONK RZ KEL B3 FORRAL RZ KEL BUS KAZ N CSATLAKOZ SA RVS SORBAKAPCSOLT RENDSZER VEZ RL SE B9 K LS RZ KEL BX1 GY JT CSONK RZ KEL BUS BUS LPB KOMPENZ TOR BUS BUS LPB...

Page 78: ...t r C 30 0 C kikapcsolva 20 0 C 1040 F t si k r 2 El remen h m alapjel min 8 C a k vetkez param tern l 1041 8 C 1041 F t si k r 2 El remen h m alapjel max Par 1041 95 C on 80 C Tervez 3 P f t k r 3 Z...

Page 79: ...ker l m g a forral t lt se be nem fejez dik Nincs a forral p rhuzamos a f t ssel MC shifting PC absolute a k zvetlen k r k z rolva maradnak m g az ACS forral t lt se be nem fejez dik Amikor a gener to...

Page 80: ...eltol s A g rbe p rhuzamos elmozd t sa egyform n m dos tja a nyom k r h m rs klet t a k ls h m rs kletek teljes intervallum n Ha a szobah m rs klet ltal ban t l meleg vagy t l hideg ki kell jav tani...

Page 81: ...rt rintkez vel DC 3 mA Anal g bemenetek H1 H3 Alacsony biztons gi fesz lts g M k d si intervallum DC 0 10 V Bels ellen ll s 100 k B9 rz kel bemenet NTC1k QAC34 B1 B2 B3 B12 BX rz kel bemenetek NTC10k...

Page 82: ...ciennego str 83 Pod czenie urz dze peryferyjnych str 84 Opis produktu str 87 Zarz dzanie urz dzeniami kontroli stref str 88 Schematy instalacji str 90 Ustawianie parametr w schemat w str 98 Krzywa te...

Page 83: ...u do g ry i zamocowa j 6 rubami tak aby listwa zabezpieczaj ca przed kurzem znalaz a si wewn trz korpusu regulatora Teraz nale y przyst pi do wprowadzenia urz dzenia do u ytku i ustawienia parametr w...

Page 84: ...Numery identyfikacyjne musz by zawsze wprowadzane kolejno pocz wszy od numeru 1 Diagnostyka Dioda C i D ZGASZONA interfejs kaskad niepod czony Dioda C ZAPALONY pod czone zasilanie do interfejsu kaska...

Page 85: ...2 Sie szynowa Nacisn przycisk OK Obracaj c pokr t em przegl da list i upewni si e w r d urz dze widoczne jest Gateway LPB MODELE CHAFFOTEAUX TOP Nacisn przycisk OK na wy wietlaczu pojawi si CODE Naci...

Page 86: ...na zewn trz gdy mog oby to zak ci pomiary Urz dzenie powinno by zainstalowane na wy soko ci ok 1 50 m od pod ogi Instalacja W przypadku monta u na ciennego nale y pozostawi odpowiedni ilo wolnego miej...

Page 87: ...xxxxxxx Xxxxxxxxxxxxxxxxxxxxxxxxxxx ECO INFO 1 2 PROG No 7 Przycisk trybu r cznego Wciskaj c przycisk w cza si tryb r czny wszystkie pompy pracuj mieszacz nie jest ju sterowany a palnik jest wyregulow...

Page 88: ...Parametr 42 Obieg c o 1 Parametr 42 Obieg c o 2 Parametr 5951 NC Po czenie elektryczne CL CL Po czenie elektryczne CL CL Po czenie elektryczne H1 M QAA75 Termostat pokojowy QAA75 Parametr 40 Jednostka...

Page 89: ...na parametrze 5890 ustawionym na warto Pompa Q20 ob c o z pomp Nacisn jeden raz przycisk OK 6 Nacisn przycisk INFO 3 a do wy wietlenia listy menu Obracaj c pokr t em 5 wybra menu Specjalista Nacisn pr...

Page 90: ...XBD BSB LPB B2 G CL CL CL CL CL CL B9 CZUJNIK ZEWN TRZNY RVS ZARZ DCA KASKAD B2 CZUJNIK KOLEKTORA T2 T1 PO CZENIE KOT A 1 QX4 FX4 PO CZENIE KOT A 2 RVS B9 B2 TA KOREKTOR TA SCHEMAT KOT W OG LNYCH MEN...

Page 91: ...p M UX M BX4 M BX3 M H3 M B12 M BX2 M BX1 M B1 M H1 M B9 M B3 M MB DB XBD BSB LPB B2 G CL CL CL CL CL CL B9 CZUJNIK ZEWN TRZNY RVS ZARZ DCA KASKAD BX1 CZUJNIK KOLEKTORA BUS PO CZENIE KOT A RVS B9 BX1...

Page 92: ...b b b a n p p M UX M BX4 M BX3 M H3 M B12 M BX2 M BX1 M B1 M H1 M B9 M B3 M MB DB XBD BSB LPB B2 G CL CL CL CL CL CL B9 CZUJNIKZEWN TRZNY RVS ZARZ DCAKASKAD BX1 CZUJNIK KOLEKTORA B12 CZUJNIKSTREFY2 B1...

Page 93: ...1 N Q2 N Q3 SK2 SK1 4 S3 T2 T1 L1 N S3 L1 L1 N L P Q R S T U T S U U Z N n n n n n n k h f b b b a n p p M UX M BX4 M BX3 M H3 M B12 M BX2 M BX1 M B1 M H1 M B9 M B3 M MB DB XBD BSB LPB B2 G CL CL CL C...

Page 94: ...2 MENU PARAMETR OPIS WARTO Specjalista Konfiguracja 5715 Obieg c o 2 aktywacja strefy 5 On Specjalista Konfiguracja 5890 Wyj przeka nika QX1 aktywacja zarz dzania strefy 6 Pompa Q20 ob c o z pomp Spec...

Page 95: ...4 M BX3 M H3 M B12 M BX2 M BX1 M B1 M H1 M B9 M B3 M MB DB XBD BSB LPB B2 G CL CL CL CL CL CL RVS 2 ZARZ DCA KASKAD B12 CZUJNIK STREFY 5 B1 CZUJNIK STREFY 4 QX4 QX3 N N QX4FX4 EX2 QX2 N Y6 Y5 N Y2 Y1...

Page 96: ...N n n n n n n k h f b b b a n p p M UX M BX4 M BX3 M H3 M B12 M BX2 M BX1 M B1 M H1 M B9 M B3 M MB DB XBD BSB LPB B2 G CL CL CL CL CL CL B9 CZUJNIK ZEWN TRZNY RVS PO CZENIE KOT A BX1 CZUJNIK KOLEKTORA...

Page 97: ...NIK CYRKULACJI BX1 CZUJNIK KOLEKTORA B3 CZUJNIK BOJLERA BUS PO CZENIE KOT A RVS ZARZ DCA KASKAD B9 CZUJNIK ZEWN TRZNY BX1 CZUJNIK KOLEKTORA BUS BUS LPB KOREKTOR BUS BUS LPB Q3 POMPA OBIEGOWA BOJLERA V...

Page 98: ...na lato zima C 30 0 C wy czona 20 0 C 1040 Obieg c o 2 Min temp zadana zasilana 8 C na par 1041 8 C 1041 Obieg c o 2 Maks temp zad zasilania par 1041 na 95 C 80 C Specjalista Obieg c o 3 P STREFA 3 ty...

Page 99: ...staj wy czone dop ki adowanie bojlera nie zostanie zako czone Brak bojler r wnolegle z ogrzewaniem Miesz zmien pom abs obwody bezpo rednie zostaj zablokowane dop ki adowanie bojlera ACS nie zostanie z...

Page 100: ...tycznej zmienia temperatur na wyj ciu w jednorodny spos b w ca ym zakresie temperatur zewn trznych Je li temperatura otoczenie jest zazwyczaj zbyt wysoka lub zbyt niska nale y skorygowa krzyw poprzez...

Page 101: ...ej cia analogowe H1 H3 Niskie napi cie bezpieczne Zakres roboczy DC 0 10 V Rezystancja wewn trzna 100 k Wej cie czujnika B9 NTC1k QAC34 Wej cia czujnika B1 B2 B3 B12 BX NTC10k QAZ36 QAD36 Dopuszczalne...

Page 102: ...102 103 104 107 108 110 118 120 121...

Page 103: ...103 6 1 2 4 5 3 4 3 60 4 6 1 5 2 230 50 L N H05 V2V2 F 3 2 3 4 a 1...

Page 104: ...R45 IC7 IC5 DL1 R32 R5 R35 D6 R33 C11 R39 IC3 R22A R22 IC9 R26 C14 R11 C16 R18 R36 Q6 R1 R30 Q2 R25 R49 R4 DZ1 C4 R21A R27 C9 IC4 IC6 R20 R38 D4 D7 IC1 Q7 CN2 R6 R29 C5 D5 D3 CN4 R50 R23A R16 FT1 R24...

Page 105: ...BSB LPB B2 G CL CL CL CL CL CL N N FLAME L L BUS T B FLOOR TA2 SE TNK SOL TA1 CN14 CN13 CN19 CN1 CN15 CN2 CN11 CN4 1 1 1 CN8 CN25 1 CN6 1 1 CN9 1 1 1 1 CN6 DL1 FT1 DL2 SW1 LPB BUS B T MB DB ARISTON TO...

Page 106: ...h f b b b a n p BX2 M BX1 M B1 M H1 M B9 M B3 M MB DB XBD BSB LPB B2 G CL CL CL CL CL CL ZONA 3 UNIT INTERNA P ZONA 2 UNIT INTERNA 2 ZONA 1 UNIT INTERNA 1 QAA 75 QAA 75 1 50 5 II 1 4 2 5 3 2 CL 1 CL 1...

Page 107: ...CS 2 4 24 24 3 ACS 5 4 ESC 4 6 ESC OK 1 2 3 4 5 6 7 8 Xxxxxxxxxxxxxxxxxxxxxxxxxxx Xxxxxxxxxxxxxxxxxxxxxxxxxxx Xxxxxxxxxxxxxxxxxxxxxxxxxxx ECO INFO 1 2 PROG No 7 60 C 8 INFO PROG ECO ECO 1 2 1 1 INFO E...

Page 108: ...AA75 5950 1 5960 2 40 5951 5961 42 3 H1 M H3 M CL CL QAA75 QAA75 40 1 40 2 5950 42 1 42 2 5951 CL CL CL CL H1 M QAA75 QAA75 40 1 5950 2 40 42 1 5951 42 3 CL CL H1 M CL CL QAA75 QAA75 5950 1 40 2 40 59...

Page 109: ...M BX4 M BX3 M H3 M B12 M BX2 M BX1 M B1 M H1 M B9 M B3 M MB DB XBD BSB LPB B2 G CL CL CL CL CL CL 1 2 2 5 OK 6 2 OK 6 3 3 5890 CRP Q20 6 INFO 3 5 OK 6 5 OK 6 5 1300 OK 6 5 OK 6 QAA75 1 2 3 4 5 6 7 8 T...

Page 110: ...K2 SK1 4 S3 T2 T1 L1 N S3 L1 L1 N L P Q R S T U T S U U Z N n n n n n n k h f b b b a n p p M UX M BX4 M BX3 M H3 M B12 M BX2 M BX1 M B1 M H1 M B9 M B3 M MB DB XBD BSB LPB B2 G CL CL CL CL CL CL B9 RV...

Page 111: ...2 SK1 4 S3 T2 T1 L1 N S3 L1 L1 N L P Q R S T U T S U U Z N n n n n n n k h f b b b a n p p M UX M BX4 M BX3 M H3 M B12 M BX2 M BX1 M B1 M H1 M B9 M B3 M MB DB XBD BSB LPB B2 G CL CL CL CL CL CL B9 RVS...

Page 112: ...FX4 EX2 QX2 N Y6 Y5 N Y2 Y1 N Q6 N QX1 N Q2 N Q3 SK2 SK1 4 S3 T2 T1 L1 N S3 L1 L1 N L P Q R S T U T S U U Z N n n n n n n k h f b b b a n p p M UX M BX4 M BX3 M H3 M B12 M BX2 M BX1 M B1 M H1 M B9 M B...

Page 113: ...QX3 N N QX4FX4 EX2 QX2 N Y6 Y5 N Y2 Y1 N Q6 N QX1 N Q2 N Q3 SK2 SK1 4 S3 T2 T1 L1 N S3 L1 L1 N L P Q R S T U T S U U Z N n n n n n n k h f b b b a n p p M UX M BX4 M BX3 M H3 M B12 M BX2 M BX1 M B1 M...

Page 114: ...BX1 BUS BUS LPB BUS BUS LPB RVS 2 Q3 QX1 3 Q6 2 Y5 Y6 B12 B1 Y1 Y2 Q2 1 QX1 6 Q6 5 Y5 Y6 B12 B1 Y1 Y2 Q2 4 VNR B3 BUS BRIDGENET 2 4 RVS 2 5715 2 5 5890 QX1 6 Q20 LPB 6600 2 LPB 6640 RVS 1 5715 2 2 58...

Page 115: ...BX4 M BX3 M H3 M B12 M BX2 M BX1 M B1 M H1 M B9 M B3 M MB DB XBD BSB LPB B2 G CL CL CL CL CL CL RVS 2 B12 5 B1 4 QX4 QX3 N N QX4FX4 EX2 QX2 N Y6 Y5 N Y2 Y1 N Q6 N QX1 N Q2 N Q3 SK2 SK1 4 S3 T2 T1 L1 N...

Page 116: ...K2 SK1 4 S3 T2 T1 L1 N S3 L1 L1 N L P Q R S T U T S U U Z N n n n n n n k h f b b b a n p p M UX M BX4 M BX3 M H3 M B12 M BX2 M BX1 M B1 M H1 M B9 M B3 M MB DB XBD BSB LPB B2 G CL CL CL CL CL CL B9 RV...

Page 117: ...T1 L1 N S3 L1 L1 N L P Q R S T U T S U U Z N n n n n n n k h f b b b a n p p M UX M BX4 M BX3 M H3 M B12 M BX2 M BX1 M B1 M H1 M B9 M B3 M MB DB XBD BSB LPB B2 G CL CL CL CL CL CL B9 RVS BX2 BX1 B3 BU...

Page 118: ...6 35 C 16 C 1014 2 4 16 C 10 C 1020 2 0 10 4 00 1 50 1021 2 4 5 4 5 C 0 0 1030 2 C 30 0 C 20 0 C 1040 2 8 C 1041 8 C 1041 2 1041 95 C 80 C 3 3 5890 1310 2 16 35 C 20 C 1312 3 16 35 C 16 C 1314 3 4 16...

Page 119: ...119 ACS 1644 1645 55 95 C 65 C 1646 360nw 10 1647 ACS 1620 24 4 24 4 4 1630 ACS 3540 3544 10 990 500 3544 3540 1 16 ACS 5020 1610 60 C 5020 15 C 60 15 75 C 75 C 0 30 C 16 C 6205...

Page 120: ...120 100 4 3 5 3 2 75 2 5 2 25 C 2 1 75 1 5 1 25 1 0 75 0 5 0 25 90 80 70 60 50 40 30 20 10 0 10 30 20 C 1 99 1 1 720 1 5 721 0 0 2 2 1020 1 5 1021 0 0 3 3 5890 1320 1 5 1321 0 0...

Page 121: ...121 230 10 50 60 10 12 3 1 3 0 10 100 k 9 NTC1k QAC34 B1 B2 B3 B12 BX NTC10k QAZ36 QAD36 Cu 0 25 0 5 0 75 1 0 1 5 2 20 40 60 80 120 0 02 2 2 A 15 A 1 6 24 230...

Page 122: ...ntaj y nergeleri sfy 123 evre ayg tlar ba lant s syf 124 r n a klamas syf 127 B lge kontrol ayg tlar n n y netimi syf 128 Elektrik diyagramlar syf 130 Parametre ayar syf 138 S cakl k ayar e risi syf 1...

Page 123: ...kablo k lar b lgesinde sonrakini delin ve bunu kablo kelep esiyle ek 4 sabitleyin T m kablolar ba land nda kapa alttan ste de i tirin ve sert k l erit s cakl k ayarlay c g vdesi i inde kalacak ekilde...

Page 124: ...lar D KKAT Elektrik ba lant lar n yapmadan veya kodu tahsis etmeden nce buhar kazan ve kontrol nitesi g beslemesini kesin Ba lant lar yaparken kutuplara dikkat edin Buhar kazan adres tahsisi Her buhar...

Page 125: ...Veriyolu a Tamam d mesine bas n D meyi evirerek listeyi kayd r n ve mevcut ay g tlar aras nda LPB A Ge idi g r nd n do rulay n CHAFFOTEAUX ST MODELLER Tamam d mesine bas n ve ekranda KOD g r n r Tama...

Page 126: ...rler g ne mi neler vb hava ak m ndan kap yollar ndan ve pencerelerden uzak yerle tirin Zemin seviyesinden yakla k 1 5 metre yukar kurulmal d r Kurulum Duvara montaj durumunda kar labilecek ve geri yer...

Page 127: ...al ma d mesi D meye bas ld nda man el al ma modu devreye girer t m pompalar n i levi kar t rma valfi art k kontrol edilmez ve br l r 60 C ye ayarlan r ekranda tornavida sembol g r n r 8 Baca temizley...

Page 128: ...5950 Calisma modu degis ist dev p Parametre 42 Topn okruh 1 Parametre 42 Topn okruh 2 Parametre 5951 NC Elektrik ba lant s CL CL Elektrik ba lant s CL CL Elektrik ba lant s H1 M QAA75 Oda termostat Q...

Page 129: ...al ma modu 5890 parametresinde etkin b lge 3 CRP Q20 Pompas de erine ayarlan r Tamam d mesine 6 bir defa bas n Men listesi g r n nceye kadar B LG d mesine 3 bas n D meyi 5 evirin ve Muhendis men s n...

Page 130: ...XBD BSB LPB B2 G CL CL CL CL CL CL B9 DI MEKAN SONDASI RVS KADEME Y NET C S B2 MAN FOLD SONDASI T2 T1 BUHAR KAZANI 1 BA LANTISI QX4 FX4 BUHAR KAZANI 2 BA LANTISI RVS B9 B2 TA KOMPANSAT R TA GENEL BUH...

Page 131: ...M H3 M B12 M BX2 M BX1 M B1 M H1 M B9 M B3 M MB DB XBD BSB LPB B2 G CL CL CL CL CL CL B9 DI MEKAN SONDASI RVS KADEME Y NET C S BX1 MAN FOLD SONDASI BUS BUHAR KAZANI BA LANTISI RVS B9 BX1 BUS BUS LPB...

Page 132: ...b a n p p M UX M BX4 M BX3 M H3 M B12 M BX2 M BX1 M B1 M H1 M B9 M B3 M MB DB XBD BSB LPB B2 G CL CL CL CL CL CL B9 DI MEKANSONDASI RVS KADEMEY NET C S BX1 MAN FOLD SONDASI B12 B LGE2SONDASI B1 B LGE...

Page 133: ...6 Y5 N Y2 Y1 N Q6 N QX1 N Q2 N Q3 SK2 SK1 4 S3 T2 T1 L1 N S3 L1 L1 N L P Q R S T U T S U U Z N n n n n n n k h f b b b a n p p M UX M BX4 M BX3 M H3 M B12 M BX2 M BX1 M B1 M H1 M B9 M B3 M MB DB XBD B...

Page 134: ...MEN PARAMETRE A IKLAMA DE ER Muhendis Yap land rma 5715 Topn okruh 2 b lge 5 etkinle tirmesi A k Muhendis Yap land rma 5890 QX1 r le giri i b lge 6 y netimi etkinle tirmesi Pompa Q20 ob c o z pomp Mu...

Page 135: ...4 M BX3 M H3 M B12 M BX2 M BX1 M B1 M H1 M B9 M B3 M MB DB XBD BSB LPB B2 G CL CL CL CL CL CL RVS 2 KADEMEY NET C S B12 B LGE 5 SONDASI B1 B LGE 4 SONDASI QX4 QX3 N N QX4FX4 EX2 QX2 N Y6 Y5 N Y2 Y1 N...

Page 136: ...f b b b a n p p M UX M BX4 M BX3 M H3 M B12 M BX2 M BX1 M B1 M H1 M B9 M B3 M MB DB XBD BSB LPB B2 G CL CL CL CL CL CL B9 DI MEKAN SONDASI RVS BUHAR KAZANI BA LANTISI BX1 MAN FOLD SONDASI B3 DEPOLAMA...

Page 137: ...BX1 MAN FOLD SONDASI B3 DEPOLAMA S L ND R SONDASI BUS BUHAR KAZANI BA LANTISI RVS KADEME Y NET C S B9 DI MEKAN SONDASI BX1 MAN FOLD SONDASI BUS BUS LPB KOMPANSAT R BUS BUS LPB Q3 DEPOLAMA S L ND R DOL...

Page 138: ...mit C 30 0 C devre d 20 0 C 1040 Topn okruh 2 Akis sicakligi set min Par 1041 de 8 C 8 C 1041 Topn okruh 2 Akis sicakligi set maks 95 C de par 1041 80 C Muhendis 3 P s tma devresi B LGE 3 yaln zca par...

Page 139: ...rudan devre depolama silindiri doldurma i lemi tamamlan ncaya kadar kapat l r Hi biri depolama silindiri ayn anda s tmaya MC otelenmis PC tam do rudan devreler DHW depolama silindirinin doldurma i le...

Page 140: ...n s cakl aral nda ayn ekilde de i tirir Oda s cakl genellikle ok s cak veya ok so uk ise e rinin paralel yer de i tirmesiyle d zeltilmelidir E ri uyarlamas Uyarlama i leviyle s cakl k ayarlay c karakt...

Page 141: ...m DC 3 mA H1 H3 analog giri ler G venli d k voltaj al ma aral DC 0 10 V diren 100 k Sonda giri i B9 NTC1k QAC34 sonda giri leri B1 B2 B3 B12 BX NTC10k QAZ36 QAD36 Sonda i in izin verilen kablolar Cu a...

Page 142: ...die Wandmontage S 143 Anschluss der Periph rger te S 144 Produktbeschreibung S 147 Regelung der Zonenkontrollvorrichtungen S 148 Anlagenpl ne S 150 Parametrisierung der Pl ne S 158 Temperaturregelungs...

Page 143: ...tzen und mit den 6 Schrauben befestigen so dass sich die Borstenleiste im Inneren des Reglergeh uses be ndet Nun mit der Inbetriebnahme und der Parametrisierung der Heizkreisl ufe und der Warmwasserer...

Page 144: ...handen LED D AUSGESCHALTET LPB Kommunikation nicht vorhanden Verbindung zwischen Kaskadenschnittstellenplatine und Heizkessel Die Kaskadensschnittstellenplatine ist in der Instrumentenhalterung des He...

Page 145: ...Sie 0 2 BUS Netz Dr cken Sie die Taste OK Drehen Sie den Drehregler um durch die Liste zu durchsuchen und zu berpr fen dass 22 unter den Vorrichtungen sichtbar ist RVS STEUERZENTRALE Die OK Taste dr c...

Page 146: ...r der Einheit eingeplant werden damit sie nach oben herausgezogen und wieder eingeschoben werden kann Abb 5 Wenn die Einheit von der Basis abgenommen wird wird die Stromversorgung unterbrochen und der...

Page 147: ...2 PROG No 7 Handbetrieb Taste Durch Dr cken dieser Taste wird der Handbetrieb aktiviert alle Pumpen sind in Betrieb der Mischer wird nicht mehr gesteuert und der Brenner ist auf 60 C eingestellt auf...

Page 148: ...Parameter 42 Heizkreislauf 1 Parameter 42 Heizkreislauf 2 Parameter 5951 NC Stromanschluss CL CL Stromanschluss CL CL Stromanschluss H1 M QAA75 Raumthermostat QAA75 Parameter 40 Raumger t 1 Parameter...

Page 149: ...ameter 5890 eingestellt auf den Wert Pumpe CRP Q20 Einmal die Taste Ok 6 dr cken Die Taste INFO 3 bis zur Visualisierung Men Liste dr cken Den Regler drehen 5 und das Experten Men ausw hlen Die Taste...

Page 150: ...ORE CASCATA B2 SONDA COLLETTORE T2 T1 COLLEGAMENTO CALDAIA 1 QX4 FX4 COLLEGAMENTO CALDAIA 2 RVS B9 B2 TA COMPENSATORE TA SCHEMA ALLGEMEINE HEIZKESSEL MEN PARAMETER BESCHREIBUNG WERT Experte Kon gurati...

Page 151: ...H1 M B9 M B3 M MB DB XBD BSB LPB B2 G CL CL CL CL CL CL B9 SONDA ESTERNA RVS GESTORE CASCATA BX1 SONDA COLLETTORE BUS COLLEGAMENTO CALDAIA RVS B9 BX1 BUS BUS LPB COMPENSATORE BUS BUS LPB SCHEMA HEIZK...

Page 152: ...CL B9 SONDA ESTERNA RVS GESTORE CASCATA BX1 SONDA COLLETTORE B12 SONDA ZONA 2 B1 SONDA ZONA 1 B3 SONDA BOLLITORE Y1 Y2 MIX ZONA 1 BUS COLLEGAMENTO CALDAIA SCHEMA HEIZKESSEL BUS BRIDGENET 1 DIREKTZONE...

Page 153: ...n n k h f b b b a n p p M UX M BX4 M BX3 M H3 M B12 M BX2 M BX1 M B1 M H1 M B9 M B3 M MB DB XBD BSB LPB B2 G CL CL CL CL CL CL RVS GESTORE CASCATA SCHEMA HEIZKESSEL BUS BRIDGENET 3 DIREKTZONEN UND BOI...

Page 154: ...AMETER BESCHREIBUNG WERT Experte Kon guration 5715 Heizkreislauf 2 Freigabe Zone 5 On Experte Kon guration 5890 Relaisausgang QX1 Freigabe Regelung Zone 6 Pumpe CRP Q20 Experte LPB 6600 Ger te Adresse...

Page 155: ...Y1 N Q6 N QX1 N Q2 N Q3 SK2 SK1 4 S3 T2 T1 L1 N S3 L1 L1 N L P Q R S T U T S U U Z N n n n n n n k h f b b b a n p p M UX M BX4 M BX3 M H3 M B12 M BX2 M BX1 M B1 M H1 M B9 M B3 M MB DB XBD BSB LPB B2...

Page 156: ...1 M B9 M B3 M MB DB XBD BSB LPB B2 G CL CL CL CL CL CL B9 SONDA ESTERNA RVS GESTORE CASCATA BX1 SONDA COLLETTORE B3 SONDA BOLLITORE BUS COLLEGAMENTO CALDAIA RVS B9 BX1 BUS BUS LPB COMPENSATORE BUS BUS...

Page 157: ...BX1 SONDA COLLETTORE BUS BUS LPB COMPENSATORE BUS BUS LPB Q3 CIRCOLATORE BOLLITORE VNR B3 SONDA BOLLITORE BX2 SONDA RICIRCOLO QX2 CIRCOLATORE RICRICOLO SCHEMA HEIZKESSEL BUS BRIDGENT EXTRA BRAUCHWASS...

Page 158: ...C ausgeschaltet 20 0 C 1040 Heizkreislauf 2 Zulauf Sollwert Min 8 C bei Par 1041 8 C 1041 Heizkreislauf 2 Zulauf Sollwert Max Par 1040 bei 95 C 80 C Experte Heizkreislauf 3 P ZONE 3 nur wenn Paramete...

Page 159: ...st der Heizung parallelgeschaltet Mischkreisl gleit Dir Kreisl absol Die direkten Kreisl ufe bleiben gesperrt bis das F llen des WW Boilers abgeschlossen ist Wenn die thermische Leistung des Generator...

Page 160: ...er Kurve ndert sich die Vorlauftemperatur gleichm ig ber den gesamten Bereich der Au entemperaturen Wenn die Umgebungstemperatur regelm ig zu hei oder zu kalt ist muss die Kurve durch eine parallele V...

Page 161: ...ossenen Kontakt DC 3 mA Analogeing nge H1 H3 Sicherheits Niederspannung Betriebsbereich DC 0 10 V Interner Widerstand 100 k Eingang F hler B9 NTC1k QAC34 Eingang F hler B1 B2 B3 B12 BX NTC10k QAZ36 QA...

Page 162: ...tru montarea la perete pag 163 Conexiuni periferiche pag 164 Descriere produs pag 167 Gestionare dispozitive control zone pag 168 Scheme instala ii pag 170 Parametrizare scheme pag 178 Curb termoregla...

Page 163: ...trebuie blocate cu bride de cablu fig 4 Dup conectarea tuturor cablurilor pozi iona i capacul de jos n sus i fixa i l cu cele 6 uruburi astfel nc t banda de p r s se afle n interiorul corpului regulat...

Page 164: ...Placa interfa cascade este amplasat n suportul pentru instrumente al centralei Fiecare plac este conectat la propria central prin conectare BUS Bridgnet Toate pl cile interfa prezente n cascad sunt c...

Page 165: ...sat tasta p n la vizualizarea listei de niveluri utilizatori Selecta i traseul Punere n serviciu Diagnoz cascad n meniul Dignoz cascad se poate verifica ce centrale sunt prezente n cascad control nd p...

Page 166: ...s fie prev zut un spa iu suficient deasupra unit ii care s permit extragerea i reintroducerea prin glisare fig 5 Dac unitatea este scoas din baza sa va nceta alimentarea a adar va fi scoas din func iu...

Page 167: ...xxxxxxxxxx ECO INFO 1 2 PROG No 7 Tast func ionare manual Ap s nd tasta se introduce func ionarea manual toate pompele sunt n func iune mixerul nu mai este comandat iar arz torul este reglat la 60 C p...

Page 168: ...it nc lzire 1 Parametrul 42 Circuit nc lzire 2 Parametrul 5951 NC Conexiune electric CL CL Conexiune electric CL CL Conexiune electric H1 M QAA75 Termostat mediu QAA75 Parametrul 40 Unitate intern 1 P...

Page 169: ...ctivat pe parametrul 5890 setat pe valoarea Pomp CRP Q20 Ap sa i o dat tasta OK 6 Ap sa i tasta INFO 3 p n la vizualizarea listei meniu Roti i selectorul 5 i alege i meniul Specialist Ap sa i tasta OK...

Page 170: ...NA RVS GESTORE CASCATA B2 SONDA COLLETTORE T2 T1 COLLEGAMENTO CALDAIA 1 QX4 FX4 COLLEGAMENTO CALDAIA 2 RVS B9 B2 TA COMPENSATORE TA SCHEM CENTRALE GENERICE MENIU PARAMETRU DESCRIERE VALOARE Specialist...

Page 171: ...BX1 M B1 M H1 M B9 M B3 M MB DB XBD BSB LPB B2 G CL CL CL CL CL CL B9 SONDA ESTERNA RVS GESTORE CASCATA BX1 SONDA COLLETTORE BUS COLLEGAMENTO CALDAIA RVS B9 BX1 BUS BUS LPB COMPENSATORE BUS BUS LPB SC...

Page 172: ...G CL CL CL CL CL CL B9 SONDA ESTERNA RVS GESTORE CASCATA BX1 SONDA COLLETTORE B12 SONDA ZONA 2 B1 SONDA ZONA 1 B3 SONDA BOLLITORE Y1 Y2 MIX ZONA 1 BUS COLLEGAMENTO CALDAIA SCHEM CENTRALE BUS BRIDGENE...

Page 173: ...U U Z N n n n n n n k h f b b b a n p p M UX M BX4 M BX3 M H3 M B12 M BX2 M BX1 M B1 M H1 M B9 M B3 M MB DB XBD BSB LPB B2 G CL CL CL CL CL CL RVS GESTORE CASCATA SCHEM CENTRALE BUS BRIDGENET 3 ZONE D...

Page 174: ...AMETRU DESCRIERE VALOARE Specialist Configurare 5 7 1 5 Circuit nc lzire 2 activare zona 5 On Specialist Configurare 5 8 9 0 Ie ire releu QX1 activare gestionare zona 6 Pompa CRP Q20 Specialist LPB 6...

Page 175: ...X4 EX2 QX2 N Y6 Y5 N Y2 Y1 N Q6 N QX1 N Q2 N Q3 SK2 SK1 4 S3 T2 T1 L1 N S3 L1 L1 N L P Q R S T U T S U U Z N n n n n n n k h f b b b a n p p M UX M BX4 M BX3 M H3 M B12 M BX2 M BX1 M B1 M H1 M B9 M B3...

Page 176: ...M B1 M H1 M B9 M B3 M MB DB XBD BSB LPB B2 G CL CL CL CL CL CL B9 SONDA ESTERNA RVS GESTORE CASCATA BX1 SONDA COLLETTORE B3 SONDA BOLLITORE BUS COLLEGAMENTO CALDAIA RVS B9 BX1 BUS BUS LPB COMPENSATOR...

Page 177: ...OLLETTORE BUS BUS LPB COMPENSATORE BUS BUS LPB Q3 CIRCOLATORE BOLLITORE VNR B3 SONDA BOLLITORE BX2 SONDA RICIRCOLO QX2 CIRCOLATORE RICRICOLO SCHEM CENTRALE BUS BRIDGENET EXTRA RECIRCULA IE SANITAR MEN...

Page 178: ...Valoare limit var iarn C 30 0 C dezactivat 20 0 C 1 0 4 0 Circuit nc lzire 2 Setpoint de tur min 8 C la par 741 8 C 1 0 4 1 Circuit nc lzire 2 Setpoint de tur max par 741 la 95 C 80 C Specialist Circu...

Page 179: ...s a terminat Niciuna boiler n paralel cu nc lzirea Circ Mix dev Circ Dir absol circuitele directe r m n blocate p n c nd nc rcarea boilerului ACS nu s a terminat C nd puterea termic a generatorului n...

Page 180: ...mod uniform pe ntregul interval de temperaturi externe Dac temperatura mediului este n general prea cald sau prea rece trebuie s se corecteze printr o deplasare paralel a curbei Adaptare curb Cu func...

Page 181: ...nchis DC 3 mA Intr ri analogice H1 H3 Tensiune de siguran sc zut C mp de lucru DC 0 10 V Rezisten intern 100 k Intrare sond B9 NTC1k QAC34 Intr ri sond B1 B2 B3 B12 BX NTC10k QAZ36 QAD36 Cabluri admi...

Page 182: ...182...

Page 183: ...183...

Page 184: ...0 Fax 0035 1219616127 comercial pt aristonthermo com www chaffoteaux pt Ariston Thermo Polska Sp z o o ul Pocieszka 3 31 408 Krak w 0048 12 420 22 20 service pl aristonthermo com www aristonthermo pl...

Reviews: