background image

Supplied By www.heating spares.co  Tel. 0161 620 6677

29

GB

See warning no. 24  - Check that the system is suitable for the maximum power
absorbed by the water heater (please refer to the data plate) and that the cross-
section of the electrical connection cables is suitable, and no less than 1.5 mm

2

.

The power supply cable (type H05 W-F 3x1.5, 8.5 mm in diameter) should be inserted
in the corresponding hole (X fig. 6) situated in the vicinity of the control knob and feed
it until it reaches the thermostat slots (T fig. 6). The electrical connection should be
made directly on the terminals (D fig. 6) of the thermostat (respect the L-N polarity).
The appliance is fitted with a cable and plug. For installations without a plug, use a
bipolar switch in conformity with the applicable norms in force (fused with a minimum
contact opening of 3 mm).
The appliance must be earthed and the earth wire (yellow-green colour) should be
fastened to the special faston on the heating element and marked with the       (PE fig.
6
). Secure the power supply cable in place using the special cable clamp provided with
the appliance

See warning no. 11

The use of multiplugs, extensions or adaptors is strictly prohibited.
It is strictly forbidden to use the piping from the plumbing, heating and gas
systems for the appliance earthing connection.

The appliance is not protected against the effects caused by lightning.
Before turning the appliance on, make sure the supply voltage complies with the value
stated on the appliance data plate and that the appliance itself is filled with water.
If the appliance is not supplied with a power supply cable, make a fixed connection to
the mains using a rigid pipe or cable for permanent installation.

Before powering the appliance, fill the tank up with mains water.
Set the knob (F fig. 6) to the desired position, plug the appliance into the socket or
switch the main switch to “ON”.
Check the appliance operation until the end of the first heating cycle, indicated by the
relative pilot lamp turning off. During the heating phase, the water expansion could
cause some trickling from the tap: this is completely normal and does not mean the
tap is faulty. Do not screw the taps too tightly to prevent damaging their seals.
In the event of a malfunction, read the paragraph regarding the MAINTENANCE
REGULATIONS.

The temperature of the water can be selected on the knob (F fig. 6) and can be adjusted
from 40 to 80

°

C approximately.

We recommend you set the temperature of the water heater to 60

°

C to:

reduce the formation of limescale;

reduce heat dispersion;

- avoid the risk of bacteria proliferation.

!

!

Starting and testing the appliance

Adjusting the operating temperature

MAINTENANCE REGULATIONS (for competent persons)

!

WARNING! Follow the general warnings and the safety norms listed at the
beginning of the text and keep to all the instructions given under all circumstances.

Anti-freeze function

If the temperatures in the room where the appliance is installed can reach particularly
low values, set the knob (F fig. 6) to setting *.
The pilot lamp (A fig. 4) stays on during the heating phase.

Summary of Contents for Piccolo ARKS 50

Page 1: ...Supplied By www heating spares co Tel 0161 620 6677 Open outlet water heater Other languages have been omited from this manual for ease of use GB Piccolo ARKS 50 ...

Page 2: ...el mag enkel met open zonder druk worden geinstalleerd Op de afvoerpijp mogen derhalve geen straalregelaars gummislangen of afsluitkranen worden bevestigd Voor dat men de boiler in werking zet moet men ervan overtuigd zijn dat de boiler vol water is Men moet om dat te bereiken de warmwaterkraan links openen en afwachten totdat geen water e meer uit de draan komt FIGYELEM A vízmelegítő szabad kifol...

Page 3: ...s anweisungen pag 17 Instructions for installation use and maintenance pag 27 Intructions pour l installation l emploi l entretien pag 37 Installatie en onderhoudsvoorschriften pag 47 Beszerelési használati és karbantartási útmutató pag 57 Návod k obsluze použití a instalaci pag 67 Instrukcja instalacji użytkowania i obsługi str 77 D GB F NL I H CZ PL ...

Page 4: ...d all other interventions must be carried out by a competent person in full conformity with the applicable legal regulations and the directions provided by the manufacturer 7 Incorrect installation can cause personal injury property damage and damage to animals the manufacturer will not be held responsible for such damage 8 Keep all packing material clips plastic bags polystyrene foam etc out of c...

Page 5: ...vibrations Electrocution from contact with live wires Explosions fires or intoxication from the discharge of gas leaking from damaged piping When piercing the wall for installation take care not to damage any electrical wiring or existing piping Damage to existing installations Flooding due to water leaking from damaged piping Damage to the appliance or any objects underneath it due to the applian...

Page 6: ... rolling ladders are positioned securely that they are suitably resistant that the steps are intact and not slippery that they are fitted with handrails on either side of the ladder and parapets on the landing Personal injury from falling from a height During all work carried out at a certain height generally with a difference in height of more than two metres make sure that parapets are used to s...

Page 7: ...perate correctly before re using the appliance Damage or shutdown of the appliance due to out of control operation SPECIFIC SAFETY NORMS FOR THIS APPLIANCE Key to symbols Symbol Warning Before handling empty all components that may contain hot water carrying out any bleeding if necessary Risk Personal injury from burns Descale the components in accordance with the instructions provided on the safe...

Page 8: ...ater supply according to the appliance performance levels and capacity Before connecting the appliance it is first necessary to Check whether the characteristics please refer to the data plate meet the customer s requirements Make sure the installation conforms to the IP degree of protection against the penetration of liquids of the appliance according to the applicable norms in force Read the ins...

Page 9: ...on of the water heater Connect the water heater inlet and outlet to resistant pipes or pipefittings as well as to the operating pressure the temperature of the hot water that could at times reach well over 80 C We advise against the use of materials that cannot withstand such high temperatures We recommend you use dielectric joints for the electrical insulation of the appliance from the water main...

Page 10: ...e complies with the value stated on the appliance data plate and that the appliance itself is filled with water If the appliance is not supplied with a power supply cable make a fixed connection to the mains using a rigid pipe or cable for permanent installation Before powering the appliance fill the tank up with mains water Set the knob F fig 6 to the desired position plug the appliance into the ...

Page 11: ...o use acids designed especially for this purpose use non metallic objects to break off the limescale crust that has formed taking care not to damage the heating element s armour We recommend you replace the seal each time you dismount the heating element To remount the heating element the tightening torque of the bolts A fig 6 should be between 7 and 10 N m You must respect the criss cross type of...

Page 12: ... soaked in soapy water See warning no 21 To clean the outer parts of the appliance use a damp cloth soaked in soapy water See warning nos 22 23 Advice for user Operation To turn the water heater on insert the plug into the wall socket or switch on the bipolar switch The pilot lamp A fig 4 only stays on during the heating cycle during this time the expanding water could cause some water to trickle ...

Page 13: ...or een boiler model boven de gootskeen H Figyelem Csaptelep a mosogató fölötti vízmelegítőhöz CZ Upozornìní Pouzivat baterie pro typ ohøivaèe s umístìním nad døez PL Uwaga należy zamontować baterię mieszającą przeznaczoną do ogr zewaczy instalowanych nad zlewem Fig 1 R Acqua calda rosso Warmwasser rot Hot water red Eau chaude rouge Warmwater rood Melegvíz piros Teplá voda èervená Woda gorąca czerw...

Page 14: ... voor een boiler model boven de gootskeen H Figyelem Csaptelep mosogató alatti vízmelegítőhöz CZ Upozornìní Pouzivat baterie pro typ ohøivaèe s umístìním pod døez PL Uwaga należy zamontować baterię mieszającą przeznaczoną do ogr zewaczy instalowanych nad zlewem Fig 2 R Acqua calda rosso Warmwasser rot Hot water red Eau chaude rouge Warmwater rood Melegvíz piros Teplá voda èervená Woda gorąca czerw...

Page 15: ...Supplied By www heating spares co Tel 0161 620 6677 85 Fig 3 ...

Page 16: ...Supplied By www heating spares co Tel 0161 620 6677 86 Fig 4 Fig 5 E C E D A A D B ...

Page 17: ...Supplied By www heating spares co Tel 0161 620 6677 87 Fig 6 PE F X D A T Fig 7 ...

Page 18: ...Supplied By www heating spares co Tel 0161 620 6677 88 Fig 8 ...

Page 19: ...Supplied By www heating spares co Tel 0161 620 6677 89 Fig 9 A ...

Page 20: ...re limiter RESET SYSTEM 1 Hőmérsékletszabályozó 2 Fűtőtest 3 Jelzőlámpa 4 Hőmérséklet határoló RESET SYSTEM 1 Régulateur de température 2 Résistance 3 Lampe témoin 4 Limiteur de température RESET SYSTEM 1 Regulace teploty 2 Odpor 3 Kontrolní zárovka 4 Havarijní termostat RESET SYSTEM 1 Temperatuurregelaar 2 Weerstand 3 Controlelampje 5 Temperatuurbegrenzer RESET SYSTEM 1 Regulator temperatury 2 Gr...