![Ariston PH 940MST Operating Instructions Manual Download Page 13](http://html1.mh-extra.com/html/ariston/ph-940mst/ph-940mst_operating-instructions-manual_2971114013.webp)
GB
13
R
S
S
A
RR
A
S
TC
TC
S
TC
TC
S
RR
A
RR
S
A
TC
SP
TC
S
RR
A
PH 941 MS
PH 941 MSTV
PH 941 MSTV GH
PC 930 T X
PH 941 MSTB
PH 941 MSTB GH
PH 960 MST
PH 960 MST GH
PH 940 MST
Table 1
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
20
17
25
28-30
20
35
37
25
45
Rapid (R)
Reduced Rapid (RR)
Semi Rapid (S)
Auxiliary (A)
Triple Crown (TC)
Semi-Fish burner (SP)
Supply
pressures
Burner
Diameter
(mm)
Thermal Power
kW (p.c.s.*)
100
100
75
55
130
-
3.00
2.60
1.65
1.00
3.25
1.50
Nominal
Reduced
0.70
0.70
0.40
0.40
1.50
0.70
By-pass
1/100
(mm)
39
39
28
28
61
39
Nozzle
1/100
(mm)
Flow*
g/h
***
86
80
64
50
91
60
Flow*
l/h
116 (Y)
110 (Y)
96 (Z)
71 (X)
133 (Z)
88
286
248
157
95
309
143
218
189
120
73
236
109
**
214
186
118
71
232
107
*
A 15°C e 1013,25 mbar-dry gas
**
Propane
P.C.S. = 50.37 MJ/Kg
***
Butane
P.C.S. = 49.47 MJ/Kg
Natural
P.C.S. = 37.78 MJ/m
Burner and nozzle specifications
3
Nozzle
1/100
(mm)
Liquid Gas
Natural Gas