2.5 Technical data table
Description
Unit of
measurement
80 L
100 L
110 L
INTERNAL UNIT
Rated tank capacity
l
80
103
110
Insulation thickness
mm
≈ 41
≈ 41
≈ 41
Type of internal tank protection
enamelling
Type of corrosion protection
titanium impressed current anode + disposable magnesium anode
Maximum operating pressure
MPa
0,8
Diameter of hydraulic connections
II
1/2 M
Diameter of gas connections
II
1/4 & 3/8 flare type
Minimum water hardness
°F
12 (with water softener, min 15 °F)
Weight when empty
kg
32
35
38
Heating element power
W
1200
1200
1200
Protection rating
IP24
IP24
IP24
Min. temperature of room of
installation
°C
1
1
1
EXTERNAL UNIT
Unit of
measurement
Heat rating (
A
)
W
1500
Average electrical power
consumption (
A
)
W
510
Max. electrical power consumption
(
A
)
W
750
Refrigerant connection diameter
II
1/4 & 3/8 flare type
Weight when empty
kg
27
Standard air flow rate
m
3
/h
1100
Sound power
dB(A)
55
Level of sound pressure at 5 m
dB(A)
39
Max. pressure of refrigerating
circuit (low-pressure side)
MPa
1.2
Max. pressure of refrigerating
circuit (high-pressure side)
MPa
2.7
Protection rating
IP24
Minimum air temperature (
C
)
°C
-5
Maximum air temperature (
C
)
°C
42
Gas connection maximum lenght
m
8
Gas connection maximum drop
(fig. 6)
m
3
Quantity of R134a refrigerant fluid
g
700