RACTICAL TIPS

- If the water is very hard, it is recommended that a water softener be added to the

system so as to reduce the formation of limescale in the boiler exchangers. This will
ensure that the efficiency of the unit remains the same over time, reducing gas
consumption and maintenance costs.

- If the boiler should be out of use for a prolonged period, it is recommended that the

electrical power supply be disconnected and that the external gas cock be closed. If low
temperatures are expected, the boiler and system pipe work should be drained in order
to prevent frost damage.

- To improve comfort and take full advantage of the heat produced by the boiler, it is

recommended that an   external (room) thermostat be installed.

- It is good practice to clean and service the appliance and central heating  system every

year. Call an Authorised Service Centre.

I

GNITION PROCEDURE

Turn the selector knob 

“A” to the “I” position. The display will

indicate 

oonn

” indicating that the boiler is ready to operate. The

electronic control unit will ignite the burner, without any manual
intervention but in response to the request for Domestic Hot Water
or heating. If, after approximately 10 seconds, the burner has not
ignited, the boiler safety devices will shut off the gas and the
display will indicate the fault code 

A

A0

01

1

. To reset the ignition

system, the reset button 

“D” must be pressed and released. Should

the boiler fail to ignite a second time, check that the external gas cock
is open. If the problem persists, contact an Authorised Service Centre.

W

INTER AND SUMMER OPERATING MODES

In the ‘winter’ operating mode, the  boiler will produce both Central
Heating and Domestic Hot Water. In the ‘summer’ operating mode,
the boiler will produce only Domestic Hot Water.
Using the knobs on the control panel, the user can select ‘winter’
or ‘summer’ operating mode.
Keeping the knob 

“C” at the “    ” position selects the ‘summer’

operating mode, the simbol “      “ will illuminate. ‘Winter’ operating
mode may be selected by positioning the knob 

“C” between the

min. and max. settings. The simbol “       “ will illuminate.

A

DJUSTING THE HEATING

It is possible to set the temperature of the Central Heating system by adjusting the knob
“C”. By positioning the indicator somewhere between min. and max., a temperature may
be obtained which varies from approximately 45˚C to about 80˚C.
The water temperature in the primary circuit  may be checked on the display.

E

XTERNAL

(

ROOM

THERMOSTAT CONTROL

If an external (room) thermostat is installed, it is recommended that the temperature of
the Central Heating system be set by means of the 

“C” knob, leaving it at max in order

to obtain the best  performance from the boiler and to allow the regulation of the external
temperature to function efficiently.

S

ETTING THE HOT WATER FOR DOMESTIC USE

Both in the winter and summer mode, the temperature of the Domestic Hot Water may be
adjusted by using the 

“B” knob. A delivery temperature for the water may be chosen in a

range from 36˚C to about 56˚C, depending on the flow rate of the water and the position
of the knob between the min. and max. settings.
The water temperature in the primary circuit  may be checked on the display.

II

II

A

PL004D

PL004D

E

C

E

C

D

PL006C

PL007D

1

2

3

4

5

6

1

2

3

4

5

6

1

2

3

4

5

6

C

PL009D

1

2

3

4

5

6

1

2

3

4

5

6

1

2

3

4

5

6

C

estate

inverno

PL007C

summer

winter

PL009D

1

2

3

4

5

6

1

2

3

4

5

6

1

2

3

4

5

6

C

PL008D

1

2

3

4

5

6

1

2

3

4

5

6

1

2

3

4

5

6

C

1

2

3

4

5

6

B

PL008D

 

       

    

  

 

 

 

 

 

                                

Summary of Contents for microGENIUS HE 24 MFFI

Page 1: ...End User Manual microGENUS HE 24 MFFI microGENUS HE 28 MFFI microGENUS HE 32 MFFI Country of destination GB 1 2 3 4 5 6 1 2 3 4 5 6 II E C...

Page 2: ...N boiler We guarantee that your boiler is a reliable and technically sound product This manual provides detailed instructions and recommendations for proper installation use and maintenance Remember t...

Page 3: ...the gas cylinder and call your Gas Supplier immediately If you are going away for a long period of time remember to shut the mains gas tap or the gas cylinder valve Before any intervention within the...

Page 4: ...that the pressure is between 1 0 and 1 5 bar the blue part on the gauge when the system is off and cool The display will indicate E E 0 02 2 if the pressure is below the minimum recommended value Con...

Page 5: ...the boiler will produce both Central Heating and Domestic Hot Water In the summer operating mode the boiler will produce only Domestic Hot Water Using the knobs on the control panel the user can selec...

Page 6: ...URE This anomaly is indicated by A A 0 01 1 on the display To reset the boiler press and then release the D button At this point the electronic ignition system will attempt to light the burner again S...

Page 7: ...s below 8 C the pump activates and runs until a temperature of 18 C is attained In the event that the water temperature falls below 3 C the diverter valve switches to Domestic Hot Water and the burner...

Page 8: ...repeat this for 7 00 pm and 10 00 pm Other heating intervals may be set in the same way The timer has approximately 150 hours of battery back up for power failure The clock is provided with a selecto...

Reviews: