background image

3

MTS (GB) Limited support the                initiative. Your installer will give you, and show
you how to use, a Log Book which will give you important information about your boiler,
and heating system. Please have this Log Book to hand whenever you contact a service
engineer or us.
All CORGI Registered Installers carry a CORGI ID card, and have a registration
number. Both should be recorded in your boiler Logbook. You can check  your
installer is CORGI registered by calling CORGI direct on :- (01256) 372300.
This is a combined appliance for the production of Central Heating (C.H.) and Domestic
Hot Water (D.H.W.). This appliance 

must be used only for the purpose for which it is

designed. The manufacturer declines all liability for damage caused by improper or
negligent use.
Do not allow children or inexperienced persons to use the appliance without supervision.
If you smell gas in the room, 

do not turn light switches on or off, use the telephone or any

other object which might cause sparks.
Open doors and windows immediately to ventilate the room.
Shut the gas mains tap (on the gas meter) or the valve of the gas cylinder and call your
Gas Supplier  immediately.
If you are going away for a long period of time, remember to shut the mains gas tap or
the gas cylinder valve.

Before any intervention within the boiler it is first necessary to isolate the electrical
supply by turning the external switch to “OFF”.

T

ECHNICAL

I

NFORMATION

GENERAL DATA

Heating input max-min (nett)
Heating output max-min (nett)
Efficiency at Maximum Thermal
Capacity (see installation instructions)

CENTRAL HEATING

Operating Temperature max-min
Maximum-Minimum Heating Pressure
Built-in expansion vessel - Total
capacity

DOMESTIC HOT WATER

Maximum-Minimum Temperature of 
Water for Domestic Use
Working pressure max-min
Flow rate 

T 25°C

Flow rate 

T 35°C

Minimum flow rate 

ELECTRICAL DATA

Electrical Supply/ Frequency
Power Consumption
Protection of Electrical System

CATEGORY

Nominal Pressure
Methane Gas (G20)
Nominal Pressure
Liquid Gas (G30-G31)

kW
kW

%

°C

bar

litres

°C

bar 

l/min
l/min
l/min

V/Hz

W
IP

mbar

mbar

26.7 - 12.2
23.3 - 10.4

87.4

82 - 42

3-0.7

7

56-36

6-0.2

13.4

9.5
2.5

230/50

120

X4D

20

28/30-37

331.1 - 13.3

27 - 11.4

86.7

82 - 42

3-0.7

7

56-36

6-0.2

15.5
11.0

2.5

230/50

148

X4D

20

28/30-37

35 - 13.3

30.5 - 11.3

87.1

82 - 42

3-0.7

7

56-36

6-0.2

17.5
12.5

2.5

230/50

148

X4D

20

28/30-37

24 kW

28 kW

32 kW

1. G

ENERAL

I

NFORMATION

Summary of Contents for microGENIUS HE 24 MFFI

Page 1: ...End User Manual microGENUS HE 24 MFFI microGENUS HE 28 MFFI microGENUS HE 32 MFFI Country of destination GB 1 2 3 4 5 6 1 2 3 4 5 6 II E C...

Page 2: ...N boiler We guarantee that your boiler is a reliable and technically sound product This manual provides detailed instructions and recommendations for proper installation use and maintenance Remember t...

Page 3: ...the gas cylinder and call your Gas Supplier immediately If you are going away for a long period of time remember to shut the mains gas tap or the gas cylinder valve Before any intervention within the...

Page 4: ...that the pressure is between 1 0 and 1 5 bar the blue part on the gauge when the system is off and cool The display will indicate E E 0 02 2 if the pressure is below the minimum recommended value Con...

Page 5: ...the boiler will produce both Central Heating and Domestic Hot Water In the summer operating mode the boiler will produce only Domestic Hot Water Using the knobs on the control panel the user can selec...

Page 6: ...URE This anomaly is indicated by A A 0 01 1 on the display To reset the boiler press and then release the D button At this point the electronic ignition system will attempt to light the burner again S...

Page 7: ...s below 8 C the pump activates and runs until a temperature of 18 C is attained In the event that the water temperature falls below 3 C the diverter valve switches to Domestic Hot Water and the burner...

Page 8: ...repeat this for 7 00 pm and 10 00 pm Other heating intervals may be set in the same way The timer has approximately 150 hours of battery back up for power failure The clock is provided with a selecto...