6.6.1 Checking the fuses
1. Remove the inspection cover on the reverse of the
control panel (F
IG
. 6.54);
2. Remove the fuses (F
IG
. 6.55).
F
IG
. 6.54
F
IG
. 6.55
M1
N1
O1
Important! Isolate the electrical supply to the boiler before
accessing the control panel.
6.5.10 Removing the D.H.W. flow switch
1. Unplug the electrical connector “M1” (F
IG
. 6.53);
2. Release nut “N1” (F
IG
. 6.53a);
3. Release the nut “O1” (F
IG
. 6.53b) and remove the
D.H.W. flow switch.