43
A7
F
IG
. 6.60
6.5.5. R
EMOVING THE
D
IVERTER
V
ALVE
A
CTUATOR
1. Unplug the electrical connector “A6” (F
IG
. 6.60);
2. Release the retaining clip “A7” and remove the diverter
valve actuator (F
IG
. 6.61).
3. Unscrew the two screws “A8” (F
IG
. 6.62);
4. Remove the “actuator” “A9” (F
IG
. 6.63 - 6.64).
F
IG
. 6.61
A8
F
IG
. 6.62
F
IG
. 6.58
F
IG
. 6.59
6.5.4. R
EMOVING THE
P
UMP
P
RESSURE
S
WITCH
(
ECO
S
YSTEM
27 RFFI)
1. Remove the electrical connections “A5” (F
IG
. 6.56);
2. Unscrew and remove (F
IG
. 6.57).
A5
A6