Fig. 93
Fig. 96
Fig. 95
Fig. 94
18.3.5 Removing the expansion vessel
18.3.6 Removing the overheat thermostat
1.
Carry out step 18.3.1;
2.
Isolate the gas supply and disconnect all pipe
connections;
3.
Remove the boiler from the wall
4.
Unscrew the nut
U
(see Fig. 97)
;
1.
Remove the casing as in step
18.1.1
;
2.
Pull off the thermostat connections. Then
remove the thermostat from the pipe by
releasing it’s securing clip
(see Fig. 99)
.
18.3.7 Removing the temperature sensors (N.T.C’s)
1.
Remove the casing as in step
18.1.1
;
2.
Pull off the NTC connections. Then remove
the NTC from the pipe by releasing it’s
securing clip
(see Fig. 100)
.
5.
Pull the expansion vessel to remove it
(see Fig. 98)
;
6.
Reassemble in reverse order.