![Ariston COMBI A 24 MFFI Operating Instructions Manual Download Page 52](http://html.mh-extra.com/html/ariston/combi-a-24-mffi/combi-a-24-mffi_operating-instructions-manual_2970958052.webp)
52
18.3.4 Removing the pressure relief valve
1.
Carry out step
18.1.1
and
18.3.1
;
2.
Remove the clip securing the valve
(see Fig. 92)
and
pull it toward you;
3.
Reassemble in reverse order; take care to ensure
the valve is in the correct position;
Fig. 92
18.3.3 Removing the pump
1.
Carry out step
18.1.1
;
2.
Lower the electrical box cover as in step
18.1.2;
3.
Remove the PCB cover;
4.
Remove the pump plug from the control board and
earth plug from the earth socket
(see Fig. 88);
Fig. 88
Fig. 89
Fig. 90
Fig. 91
S2
S3
6.
Unscrew the pump nut
(see Fig. 89);
5.
Remove the clip
S2
on the pump volute
(see Fig. 90);
7.
Pull the pump toward you and remove the clip
S3
securing the pressure gauge
(see Fig. 91);
8.
Reassemble in reverse order.