82
IT
GB
installation
Positioning
The appliance detects the room tempera-
ture, therefore several factors should be
taken into account when choosing an instal-
lation site. Keep it away from sources of heat
(radiators, sunlight, fi replaces, etc.) and from
draughts, doorways and windows which
could aff ect the temperature readings.
It should be installed approximately 1.50
metres above the fl oor level.
Caution!
Installation should be performed by a quali-
fi ed technician.
Before fi tting the appliance, make sure the
electricity supply is not connected.
Installation
The Clima Manager must be fi tted to the
wall before the BUS line is connected.
• Separate the fi xing base by inserting a
screwdriver into the two cracks on the
lower part.
• Fix the Clima Manager base to the wall at
the chosen point, using the screws sup-
plied in the kit.