6
Zone 3 Pa-
rameters
60 Set temperatures
600 Day Temperature
10 ÷ 30 °C
601 Nigh Temperature
10 ÷ 30 °C
602 Fixed Temperature
20 ÷ 85 °C
61 Access code
62 Zone 3 settings
620 System temperature range
0 : Low temperature
milti-zone
module
1 : High temperature
621 Temperature adjustment
0 : Fixed fl ow temperature
1 : On/off devices
2 : Room sensor only
3 : Outdoor sensor only
4 : Room Outdoor sensor
622 Slope
0,2 ÷ 3,5
623 Off set
-20 ÷ +20
624 Room infl uence
0 ÷ 20
625 Max. Temperature
626 Min. Temperature
63 Zone 2 diagnostics
630 Room Temperature
read-only
631 Flow Temperature
632 Return Temperature
633 Set Temperature
multizone
module
634 Request status
635 Pump status